533 related articles for article (PubMed ID: 26748432)
1. External validation of IOTA simple descriptors and simple rules for classifying adnexal masses.
Alcázar JL; Pascual MA; Graupera B; Aubá M; Errasti T; Olartecoechea B; Ruiz-Zambrana A; Hereter L; Ajossa S; Guerriero S
Ultrasound Obstet Gynecol; 2016 Sep; 48(3):397-402. PubMed ID: 26748432
[TBL] [Abstract][Full Text] [Related]
2. Prospective external validation of IOTA three-step strategy for characterizing and classifying adnexal masses and retrospective assessment of alternative two-step strategy using simple-rules risk.
Hidalgo JJ; Ros F; Aubá M; Errasti T; Olartecoechea B; Ruiz-Zambrana Á; Alcázar JL
Ultrasound Obstet Gynecol; 2019 May; 53(5):693-700. PubMed ID: 30353585
[TBL] [Abstract][Full Text] [Related]
3. Diagnostic performance of IOTA simple rules for adnexal masses classification: a comparison between two centers with different ovarian cancer prevalence.
Ruiz de Gauna B; Rodriguez D; Olartecoechea B; Aubá M; Jurado M; Gómez Roig MD; Alcázar JL
Eur J Obstet Gynecol Reprod Biol; 2015 Aug; 191():10-4. PubMed ID: 26066289
[TBL] [Abstract][Full Text] [Related]
4. IOTA simple rules for discriminating between benign and malignant adnexal masses: prospective external validation.
Alcázar JL; Pascual MÁ; Olartecoechea B; Graupera B; Aubá M; Ajossa S; Hereter L; Julve R; Gastón B; Peddes C; Sedda F; Piras A; Saba L; Guerriero S
Ultrasound Obstet Gynecol; 2013 Oct; 42(4):467-71. PubMed ID: 23576304
[TBL] [Abstract][Full Text] [Related]
5. Interobserver agreement in describing adnexal masses using the International Ovarian Tumor Analysis simple rules in a real-time setting and using three-dimensional ultrasound volumes and digital clips.
Ruiz de Gauna B; Sanchez P; Pineda L; Utrilla-Layna J; Juez L; Alcázar JL
Ultrasound Obstet Gynecol; 2014 Jul; 44(1):95-9. PubMed ID: 24265132
[TBL] [Abstract][Full Text] [Related]
6. Ultrasound examination, MRI, or ROMA for discriminating between inconclusive adnexal masses as determined by IOTA Simple Rules: a prospective study.
Chacon E; Arraiza M; Manzour N; Benito A; Mínguez JÁ; Vázquez-Vicente D; Castellanos T; Chiva L; Alcazar JL
Int J Gynecol Cancer; 2023 Jun; 33(6):951-956. PubMed ID: 37055169
[TBL] [Abstract][Full Text] [Related]
7. Simple ultrasound rules to distinguish between benign and malignant adnexal masses before surgery: prospective validation by IOTA group.
Timmerman D; Ameye L; Fischerova D; Epstein E; Melis GB; Guerriero S; Van Holsbeke C; Savelli L; Fruscio R; Lissoni AA; Testa AC; Veldman J; Vergote I; Van Huffel S; Bourne T; Valentin L
BMJ; 2010 Dec; 341():c6839. PubMed ID: 21156740
[TBL] [Abstract][Full Text] [Related]
8. Lesion size affects diagnostic performance of IOTA logistic regression models, IOTA simple rules and risk of malignancy index in discriminating between benign and malignant adnexal masses.
Di Legge A; Testa AC; Ameye L; Van Calster B; Lissoni AA; Leone FP; Savelli L; Franchi D; Czekierdowski A; Trio D; Van Holsbeke C; Ferrazzi E; Scambia G; Timmerman D; Valentin L
Ultrasound Obstet Gynecol; 2012 Sep; 40(3):345-54. PubMed ID: 22611001
[TBL] [Abstract][Full Text] [Related]
9. Estimating risk of malignancy in adnexal masses: external validation of the ADNEX model and comparison with other frequently used ultrasound methods.
Meys EMJ; Jeelof LS; Achten NMJ; Slangen BFM; Lambrechts S; Kruitwagen RFPM; Van Gorp T
Ultrasound Obstet Gynecol; 2017 Jun; 49(6):784-792. PubMed ID: 27514486
[TBL] [Abstract][Full Text] [Related]
10. The Prospective External Validation of International Ovarian Tumor Analysis (IOTA) Simple Rules in the Hands of Level I and II Examiners.
Knafel A; Banas T; Nocun A; Wiechec M; Jach R; Ludwin A; Kabzinska-Turek M; Pietrus M; Pitynski K
Ultraschall Med; 2016 Oct; 37(5):516-523. PubMed ID: 26126150
[No Abstract] [Full Text] [Related]
11. Performance of three-dimensional power Doppler angiography as third-step assessment in differential diagnosis of adnexal masses.
Utrilla-Layna J; Alcázar JL; Aubá M; Laparte C; Olartecoechea B; Errasti T; Juez L; Mínguez JÁ; Guerriero S; Jurado M
Ultrasound Obstet Gynecol; 2015 May; 45(5):613-7. PubMed ID: 25270368
[TBL] [Abstract][Full Text] [Related]
12. Clinically oriented three-step strategy for assessment of adnexal pathology.
Ameye L; Timmerman D; Valentin L; Paladini D; Zhang J; Van Holsbeke C; Lissoni AA; Savelli L; Veldman J; Testa AC; Amant F; Van Huffel S; Bourne T
Ultrasound Obstet Gynecol; 2012 Nov; 40(5):582-91. PubMed ID: 22511559
[TBL] [Abstract][Full Text] [Related]
13. Assessing the reproducibility of the IOTA simple ultrasound rules for classifying adnexal masses as benign or malignant using stored 3D volumes.
Guerriero S; Saba L; Ajossa S; Peddes C; Sedda F; Piras A; Olartecoechea B; Aubá M; Alcázar JL
Eur J Obstet Gynecol Reprod Biol; 2013 Nov; 171(1):157-60. PubMed ID: 24060210
[TBL] [Abstract][Full Text] [Related]
14. Diagnostic accuracy and cost-effectiveness of different strategies to triage women with adnexal masses: a prospective study.
Piovano E; Cavallero C; Fuso L; Viora E; Ferrero A; Gregori G; Grillo C; Macchi C; Mengozzi G; Mitidieri M; Pagano E; Zola P
Ultrasound Obstet Gynecol; 2017 Sep; 50(3):395-403. PubMed ID: 27706929
[TBL] [Abstract][Full Text] [Related]
15. Simple descriptors and simple rules of the International Ovarian Tumor Analysis (IOTA) Group: a prospective study of combined use for the description of adnexal masses.
Peces Rama A; Llanos Llanos MC; Sánchez Ferrer ML; Alcázar Zambrano JL; Martínez Mendoza A; Nieto Díaz A
Eur J Obstet Gynecol Reprod Biol; 2015 Dec; 195():7-11. PubMed ID: 26461961
[TBL] [Abstract][Full Text] [Related]
16. Vessel morphology depicted by three-dimensional power Doppler ultrasound as second-stage test in adnexal tumors that are difficult to classify: prospective diagnostic accuracy study.
Sladkevicius P; Jokubkiene L; Timmerman D; Fischerova D; Van Holsbeke C; Franchi D; Savelli L; Epstein E; Fruscio R; Kaijser J; Czekierdowski A; Guerriero S; Pascual MA; Testa AC; Ameye L; Valentin L
Ultrasound Obstet Gynecol; 2021 Feb; 57(2):324-334. PubMed ID: 32853459
[TBL] [Abstract][Full Text] [Related]
17. Comparison of IOTA three-step strategy and logistic regression model LR2 for discriminating between benign and malignant adnexal masses.
Hidalgo JJ; Llueca A; Zolfaroli I; Veiga N; Ortiz E; Alcázar JL
Med Ultrason; 2021 May; 23(2):168-175. PubMed ID: 33626112
[TBL] [Abstract][Full Text] [Related]
18. Evaluating use of IOTA two-step strategy to classify adnexal masses identified in pregnancy: pilot study.
Barcroft J; Pandrich M; Del Forno S; Cooper N; Linton-Reid K; Landolfo C; Timmerman D; Saso S; Bourne T
Ultrasound Obstet Gynecol; 2024 May; ():. PubMed ID: 38787921
[TBL] [Abstract][Full Text] [Related]
19. IOTA Simple Rules in Differentiating between Benign and Malignant Adnexal Masses by Non-expert Examiners.
Tinnangwattana D; Vichak-Ururote L; Tontivuthikul P; Charoenratana C; Lerthiranwong T; Tongsong T
Asian Pac J Cancer Prev; 2015; 16(9):3835-8. PubMed ID: 25987045
[TBL] [Abstract][Full Text] [Related]
20. Performance of IOTA ADNEX model in evaluating adnexal masses in a gynecological oncology center in China.
Chen H; Qian L; Jiang M; Du Q; Yuan F; Feng W
Ultrasound Obstet Gynecol; 2019 Dec; 54(6):815-822. PubMed ID: 31152572
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]