BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 26749328)

  • 1. Automated Assessment of Left Ventricular Function and Mass Using Heart Deformation Analysis: Initial Experience in 160 Older Adults.
    Lin K; Collins JD; Lloyd-Jones DM; Jolly MP; Li D; Markl M; Carr JC
    Acad Radiol; 2016 Mar; 23(3):321-5. PubMed ID: 26749328
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Heart deformation analysis for automated quantification of cardiac function and regional myocardial motion patterns: A proof of concept study in patients with cardiomyopathy and healthy subjects.
    Lin K; Collins JD; Chowdhary V; Markl M; Carr JC
    Eur J Radiol; 2016 Oct; 85(10):1811-1817. PubMed ID: 27666621
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of observer-dependency on left ventricular hypertrabeculation mass measurement and its relationship with left ventricular volume and ejection fraction -  comparison between manual and semiautomatic CMR image analysis methods.
    Kubik M; Dąbrowska-Kugacka A; Dorniak K; Kutniewska-Kubik M; Daniłowicz-Szymanowicz L; Lewicka E; Szurowska E; Raczak G
    PLoS One; 2020; 15(3):e0230134. PubMed ID: 32160262
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heart deformation analysis: measuring regional myocardial velocity with MR imaging.
    Lin K; Collins JD; Chowdhary V; Markl M; Carr JC
    Int J Cardiovasc Imaging; 2016 Jul; 32(7):1103-11. PubMed ID: 27076222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reproducibility of cine displacement encoding with stimulated echoes (DENSE) in human subjects.
    Lin K; Meng L; Collins JD; Chowdhary V; Markl M; Carr JC
    Magn Reson Imaging; 2017 Jan; 35():148-153. PubMed ID: 27569367
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of left ventricular volumes, mass, and ejection fraction using cine displacement encoding with stimulated echoes (DENSE) MRI.
    Haggerty CM; Kramer SP; Skrinjar O; Binkley CM; Powell DK; Mattingly AC; Epstein FH; Fornwalt BK
    J Magn Reson Imaging; 2014 Aug; 40(2):398-406. PubMed ID: 24923710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biplane versus short-axis measures of the left atrium and ventricle in patients with systolic dysfunction assessed by magnetic resonance.
    Nanni S; Westenberg JJ; Bax JJ; Siebelink HM; de Roos A; Kroft LJ
    Clin Imaging; 2016; 40(5):907-12. PubMed ID: 27183139
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences.
    Kunz RP; Oellig F; Krummenauer F; Oberholzer K; Romaneehsen B; Vomweg TW; Horstick G; Hayes C; Thelen M; Kreitner KF
    J Magn Reson Imaging; 2005 Feb; 21(2):140-8. PubMed ID: 15666401
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Multislice TrueFISP-MR imaging for identifying stress-induced myocardial functional disturbances in coronary heart disease].
    Kramer U; Fenchel M; Helber U; Kraft A; Stauder NI; Franow A; Claussen CD; Miller S
    Rofo; 2003 Oct; 175(10):1355-62. PubMed ID: 14556104
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantification of left and right ventricular function and myocardial mass: comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI.
    Takx RA; Moscariello A; Schoepf UJ; Barraza JM; Nance JW; Bastarrika G; Das M; Meyer M; Wildberger JE; Schoenberg SO; Fink C; Henzler T
    Eur J Radiol; 2012 Apr; 81(4):e598-604. PubMed ID: 21831552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative analysis of cardiac left ventricular variables obtained by MRI at 3 T: a pre- and post-contrast comparison.
    Matthew S; Gandy SJ; Nicholas RS; Waugh SA; Crowe EA; Lerski RA; Dunn MH; Houston JG
    Br J Radiol; 2012 Jul; 85(1015):e343-7. PubMed ID: 22745212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The consistency of myocardial strain derived from heart deformation analysis.
    Keller EJ; Fang S; Lin K; Freed BH; Smith PM; Spottiswoode BS; Davids R; Carr M; Jolly MP; Markl M; Carr JC; Collins JD
    Int J Cardiovasc Imaging; 2017 Aug; 33(8):1169-1177. PubMed ID: 28239799
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feedback-assisted three-dimensional reconstruction of the left ventricle with MRI.
    Swingen CM; Seethamraju RT; Jerosch-Herold M
    J Magn Reson Imaging; 2003 May; 17(5):528-37. PubMed ID: 12720262
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Left ventricular mass and volume: fast calculation with guide-point modeling on MR images.
    Young AA; Cowan BR; Thrupp SF; Hedley WJ; Dell'Italia LJ
    Radiology; 2000 Aug; 216(2):597-602. PubMed ID: 10924592
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Left ventricular function: MRI assessment.
    Di Cesare E; Catalucci A; Masciocchi C
    Rays; 1999; 24(1):19-32. PubMed ID: 10358381
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Assessment of global and regional left ventricular function with a 16-slice spiral-CT using two different software tools for quantitative functional analysis and qualitative evaluation of wall motion changes in comparison with magnetic resonance imaging].
    Koch K; Oellig F; Kunz P; Bender P; Oberholzer K; Mildenberger P; Hake U; Kreitner KF; Thelen M
    Rofo; 2004 Dec; 176(12):1786-93. PubMed ID: 15573290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The exactness of left ventricular segmentation in cine magnetic resonance imaging and its impact on systolic function values.
    Barbier CE; Johansson L; Lind L; Ahlström H; Bjerner T
    Acta Radiol; 2007 Apr; 48(3):285-91. PubMed ID: 17453498
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass.
    Vincenti G; Monney P; Chaptinel J; Rutz T; Coppo S; Zenge MO; Schmidt M; Nadar MS; Piccini D; Chèvre P; Stuber M; Schwitter J
    JACC Cardiovasc Imaging; 2014 Sep; 7(9):882-92. PubMed ID: 25129517
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction.
    Dornier C; Somsen GA; Ivancevic MK; Osman NF; Didier D; Righetti A; Vallée JP
    Eur Radiol; 2004 Aug; 14(8):1348-52. PubMed ID: 15067425
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol-enhanced 4D flow MRI.
    Hanneman K; Kino A; Cheng JY; Alley MT; Vasanawala SS
    J Magn Reson Imaging; 2016 Aug; 44(2):383-92. PubMed ID: 26871420
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.