These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 26756410)

  • 1. The impact of the number of projections on image quality in Compton scatter tomography.
    Chighvinadze T; Pistorius S
    J Xray Sci Technol; 2015; 23(6):745-58. PubMed ID: 26756410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT energy weighting in the presence of scatter and limited energy resolution.
    Schmidt TG
    Med Phys; 2010 Mar; 37(3):1056-67. PubMed ID: 20384241
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of detector size and energy resolution on image quality in multi-projection Compton scatter tomography.
    Chighvinadze T; Pistorius S
    J Xray Sci Technol; 2014; 22(1):113-28. PubMed ID: 24463390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.
    Lasio GM; Whiting BR; Williamson JF
    Phys Med Biol; 2007 Apr; 52(8):2247-66. PubMed ID: 17404467
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections.
    Bootsma GJ; Verhaegen F; Jaffray DA
    Med Phys; 2013 Nov; 40(11):111901. PubMed ID: 24320434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Poster - Thur Eve - 14: The effect of fluence and detector size on image quality in multi-projection compton scatter tomography.
    Chighvinadze T; Pistorius S
    Med Phys; 2012 Jul; 39(7Part2):4626-4627. PubMed ID: 28516521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.
    Lim K; Kwon H; Cho J; Oh J; Yoon S; Kang M; Ha D; Lee J; Kang E
    J Comput Assist Tomogr; 2015; 39(3):443-8. PubMed ID: 25654782
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT.
    Zbijewski W; Beekman FJ
    IEEE Trans Med Imaging; 2006 Jul; 25(7):817-27. PubMed ID: 16827483
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of Compton-scatter imaging with an analytical simulation method.
    Jones KC; Redler G; Templeton A; Bernard D; Turian JV; Chu JCH
    Phys Med Biol; 2018 Jan; 63(2):025016. PubMed ID: 29243663
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection.
    van Stevendaal U; Schlomka JP; Harding A; Grass M
    Med Phys; 2003 Sep; 30(9):2465-74. PubMed ID: 14528968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.
    Roessl E; Proksa R
    Phys Med Biol; 2007 Aug; 52(15):4679-96. PubMed ID: 17634657
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Energy-resolved computed tomography: first experimental results.
    Shikhaliev PM
    Phys Med Biol; 2008 Oct; 53(20):5595-613. PubMed ID: 18799830
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Monte Carlo-based model for simulation of digital chest tomosynthesis.
    Ullman G; Dance DR; Sandborg M; Carlsson GA; Svalkvist A; Båth M
    Radiat Prot Dosimetry; 2010; 139(1-3):159-63. PubMed ID: 20203125
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Time-delayed summation as a means of improving resolution on fast rotating computed tomography systems.
    Nowak T; Hupfer M; Althoff F; Brauweiler R; Eisa F; Steiding C; Kalender WA
    Med Phys; 2012 Apr; 39(4):2249-60. PubMed ID: 22482646
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Region-of-interest material decomposition from truncated energy-resolved CT.
    Schmidt TG; Pektas F
    Med Phys; 2011 Oct; 38(10):5657-66. PubMed ID: 21992382
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of scatter effects on image quality for breast tomosynthesis.
    Wu G; Mainprize JG; Boone JM; Yaffe MJ
    Med Phys; 2009 Oct; 36(10):4425-32. PubMed ID: 19928073
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of acquisition parameters on MV-CBCT image quality.
    Gayou O
    J Appl Clin Med Phys; 2012 Jan; 13(1):3638. PubMed ID: 22231215
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.
    Roessl E; Brendel B; Engel KJ; Schlomka JP; Thran A; Proksa R
    IEEE Trans Med Imaging; 2011 Sep; 30(9):1678-90. PubMed ID: 21507770
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.
    Kulkarni NM; Sahani DV; Desai GS; Kalva SP
    J Vasc Interv Radiol; 2012 Jul; 23(7):879-86. PubMed ID: 22633619
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: feasibility study in lung cancer screening.
    Ohkubo M; Wada S; Kayugawa A; Matsumoto T; Murao K
    Med Phys; 2011 Jul; 38(7):3915-23. PubMed ID: 21858988
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.