BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 26757540)

  • 1. [Progress on treatment of transverse patella fractures with tension band fixation].
    Yu XL; Xu C; Li SD; Zhan JD; Xu ZQ
    Zhongguo Gu Shang; 2015 Nov; 28(11):1069-74. PubMed ID: 26757540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.
    Hsu KL; Chang WL; Yang CY; Yeh ML; Chang CW
    Injury; 2017 Dec; 48(12):2800-2806. PubMed ID: 29037518
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
    Dargel J; Gick S; Mader K; Koebke J; Pennig D
    Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new and effective tension-band braided polyester suture technique for transverse patellar fracture fixation.
    Hughes SC; Stott PM; Hearnden AJ; Ripley LG
    Injury; 2007 Feb; 38(2):212-22. PubMed ID: 17098238
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
    Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
    J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
    Liu C; Ren H; Wan C; Ma J
    Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].
    Zhang J; Jiang XY; Huang XW
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Jun; 48(3):534-8. PubMed ID: 27318920
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.
    Ling M; Zhan S; Jiang D; Hu H; Zhang C
    J Orthop Surg Res; 2019 Jan; 14(1):14. PubMed ID: 30634995
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modified tension band technique for patella fractures.
    Lefaivre KA; O'Brien PJ; Broekhuyse HM; Guy P; Blachut PA
    Orthop Traumatol Surg Res; 2010 Sep; 96(5):579-82. PubMed ID: 20663733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.
    Tian Y; Zhou F; Ji H; Zhang Z; Guo Y
    Clin Orthop Relat Res; 2011 Dec; 469(12):3429-35. PubMed ID: 21573937
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical comparison of fixation methods in transverse patella fractures.
    Scilaris TA; Grantham JL; Prayson MJ; Marshall MP; Hamilton JJ; Williams JL
    J Orthop Trauma; 1998; 12(5):356-9. PubMed ID: 9671189
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Analysis of the Kirschner-Wire Depth of the Modified Tension Band Wiring Technique in Transverse Patellar Fractures: An Experimental Study Using the Finite-Element Method.
    Kim Y; Kwon M; Ryu JY; Moon SW
    Clin Orthop Surg; 2021 Sep; 13(3):315-319. PubMed ID: 34484623
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.
    Aydın E; Dülgeroğlu TC; Metineren H
    J Med Case Rep; 2016 Feb; 10():41. PubMed ID: 26911242
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Displaced patella fractures.
    Della Rocca GJ
    J Knee Surg; 2013 Oct; 26(5):293-9. PubMed ID: 23966286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers.
    Karadeniz E; Keskinoz EN
    J Orthop Surg Res; 2020 Jul; 15(1):256. PubMed ID: 32650813
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.
    Yang TY; Huang TW; Chuang PY; Huang KC
    BMC Musculoskelet Disord; 2018 May; 19(1):167. PubMed ID: 29793461
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental investigation of the tension band in fractures of the patella.
    Fortis AP; Milis Z; Kostopoulos V; Tsantzalis S; Kormas P; Tzinieris N; Boudouris T
    Injury; 2002 Jul; 33(6):489-93. PubMed ID: 12098544
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire.
    Chang CW; Chen YN; Li CT; Chung YH; Chang CH; Peng YT
    J Orthop Surg (Hong Kong); 2018; 26(3):2309499018789705. PubMed ID: 30037293
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.