202 related articles for article (PubMed ID: 26757540)
1. [Progress on treatment of transverse patella fractures with tension band fixation].
Yu XL; Xu C; Li SD; Zhan JD; Xu ZQ
Zhongguo Gu Shang; 2015 Nov; 28(11):1069-74. PubMed ID: 26757540
[TBL] [Abstract][Full Text] [Related]
2. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.
Hsu KL; Chang WL; Yang CY; Yeh ML; Chang CW
Injury; 2017 Dec; 48(12):2800-2806. PubMed ID: 29037518
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
Dargel J; Gick S; Mader K; Koebke J; Pennig D
Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
[TBL] [Abstract][Full Text] [Related]
5. A new and effective tension-band braided polyester suture technique for transverse patellar fracture fixation.
Hughes SC; Stott PM; Hearnden AJ; Ripley LG
Injury; 2007 Feb; 38(2):212-22. PubMed ID: 17098238
[TBL] [Abstract][Full Text] [Related]
6. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
[TBL] [Abstract][Full Text] [Related]
7. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
[TBL] [Abstract][Full Text] [Related]
8. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
Liu C; Ren H; Wan C; Ma J
Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
[TBL] [Abstract][Full Text] [Related]
9. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].
Zhang J; Jiang XY; Huang XW
Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Jun; 48(3):534-8. PubMed ID: 27318920
[TBL] [Abstract][Full Text] [Related]
10. Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.
Ling M; Zhan S; Jiang D; Hu H; Zhang C
J Orthop Surg Res; 2019 Jan; 14(1):14. PubMed ID: 30634995
[TBL] [Abstract][Full Text] [Related]
11. Modified tension band technique for patella fractures.
Lefaivre KA; O'Brien PJ; Broekhuyse HM; Guy P; Blachut PA
Orthop Traumatol Surg Res; 2010 Sep; 96(5):579-82. PubMed ID: 20663733
[TBL] [Abstract][Full Text] [Related]
12. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.
Tian Y; Zhou F; Ji H; Zhang Z; Guo Y
Clin Orthop Relat Res; 2011 Dec; 469(12):3429-35. PubMed ID: 21573937
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical comparison of fixation methods in transverse patella fractures.
Scilaris TA; Grantham JL; Prayson MJ; Marshall MP; Hamilton JJ; Williams JL
J Orthop Trauma; 1998; 12(5):356-9. PubMed ID: 9671189
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical Analysis of the Kirschner-Wire Depth of the Modified Tension Band Wiring Technique in Transverse Patellar Fractures: An Experimental Study Using the Finite-Element Method.
Kim Y; Kwon M; Ryu JY; Moon SW
Clin Orthop Surg; 2021 Sep; 13(3):315-319. PubMed ID: 34484623
[TBL] [Abstract][Full Text] [Related]
15. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.
Aydın E; Dülgeroğlu TC; Metineren H
J Med Case Rep; 2016 Feb; 10():41. PubMed ID: 26911242
[TBL] [Abstract][Full Text] [Related]
16. Displaced patella fractures.
Della Rocca GJ
J Knee Surg; 2013 Oct; 26(5):293-9. PubMed ID: 23966286
[TBL] [Abstract][Full Text] [Related]
17. A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers.
Karadeniz E; Keskinoz EN
J Orthop Surg Res; 2020 Jul; 15(1):256. PubMed ID: 32650813
[TBL] [Abstract][Full Text] [Related]
18. Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.
Yang TY; Huang TW; Chuang PY; Huang KC
BMC Musculoskelet Disord; 2018 May; 19(1):167. PubMed ID: 29793461
[TBL] [Abstract][Full Text] [Related]
19. Experimental investigation of the tension band in fractures of the patella.
Fortis AP; Milis Z; Kostopoulos V; Tsantzalis S; Kormas P; Tzinieris N; Boudouris T
Injury; 2002 Jul; 33(6):489-93. PubMed ID: 12098544
[TBL] [Abstract][Full Text] [Related]
20. Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire.
Chang CW; Chen YN; Li CT; Chung YH; Chang CH; Peng YT
J Orthop Surg (Hong Kong); 2018; 26(3):2309499018789705. PubMed ID: 30037293
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]