These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

856 related articles for article (PubMed ID: 26759257)

  • 21. Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures.
    Apivatthakakul T; Phornphutkul C; Bunmaprasert T; Sananpanich K; Fernandez Dell'Oca A
    Arch Orthop Trauma Surg; 2012 Jun; 132(6):813-22. PubMed ID: 22389063
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Periprosthetic femoral fractures after total hip arthroplasty: An algorithm of treatment.
    Pavone V; de Cristo C; Di Stefano A; Costarella L; Testa G; Sessa G
    Injury; 2019 Jul; 50 Suppl 2():S45-S51. PubMed ID: 30765184
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Plate osteosynthesis in vancouver type b1 and b2 periprosthetic fractures].
    Fousek J; Vasek P
    Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):410-6. PubMed ID: 19912706
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis: fracture union and reoperations in 60 consecutive fractures.
    Froberg L; Troelsen A; Brix M
    Acta Orthop; 2012 Dec; 83(6):648-52. PubMed ID: 23140109
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Outcome of periprosthetic distal femoral fractures following knee arthroplasty.
    Hoffmann MF; Jones CB; Sietsema DL; Koenig SJ; Tornetta P
    Injury; 2012 Jul; 43(7):1084-9. PubMed ID: 22348954
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of strut allograft and its position on Vancouver type B1 periprosthetic femoral fractures: a biomechanical study.
    Sariyilmaz K; Dikici F; Dikmen G; Bozdag E; Sunbuloglu E; Bekler B; Yazicioglu O
    J Arthroplasty; 2014 Jul; 29(7):1485-90. PubMed ID: 24656637
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A systematic review of open reduction and internal fixation of periprosthetic femur fractures with or without allograft strut, cerclage, and locked plates.
    Moore RE; Baldwin K; Austin MS; Mehta S
    J Arthroplasty; 2014 May; 29(5):872-6. PubMed ID: 24650900
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Treatment of Periprosthetic Femoral Fractures after Total Hip Arthroplasty Vancouver Type B.
    Bulatović N; Kezunović M; Vučetić Č; Abdić N; Benčić I; Čengić T
    Acta Clin Croat; 2017 Sep; 56(3):536-543. PubMed ID: 29479920
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Uncemented extensive porous titanium-coated long femoral stem prostheses are effective in treatment of Vancouver type B2 periprosthetic femoral fractures: A retrospective mid- to long-term follow-up study.
    Wang Q; Li D; Kang P
    J Orthop Surg (Hong Kong); 2019; 27(2):2309499019857653. PubMed ID: 31232172
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up.
    Xue H; Tu Y; Cai M; Yang A
    J Arthroplasty; 2011 Apr; 26(3):467-471.e1. PubMed ID: 20570098
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Minimally invasive fixation of type B and C interprosthetic femoral fractures.
    Ehlinger M; Czekaj J; Adam P; Brinkert D; Ducrot G; Bonnomet F
    Orthop Traumatol Surg Res; 2013 Sep; 99(5):563-9. PubMed ID: 23769162
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Outcome of periprosthetic femoral fractures following total hip replacement treated with polyaxial locking plate.
    Hoffmann MF; Lotzien S; Schildhauer TA
    Eur J Orthop Surg Traumatol; 2017 Jan; 27(1):107-112. PubMed ID: 27600334
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Surgical treatment of periprosthetic femoral fractures following hip arthroplasty: our institutional experience.
    Kinov P; Volpin G; Sevi R; Tanchev PP; Antonov B; Hakim G
    Injury; 2015 Oct; 46(10):1945-50. PubMed ID: 26115579
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical outcome of interprosthetic femoral fractures treated with polyaxial locking plates.
    Hoffmann MF; Lotzien S; Schildhauer TA
    Injury; 2016 Apr; 47(4):934-8. PubMed ID: 26792022
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Surgical outcomes of cable plate fixation in treatment of Vancouver type B1 and type C periprosthetic femoral fractures: a retrospective case series.
    Şen C; Kızılkurt T; Demirel M; Yıldırım AM; Sağlam Y; Öztürk İ
    Acta Orthop Traumatol Turc; 2024 Sep; 58(4):235-243. PubMed ID: 39323230
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Factors affecting peri-implant fracture following locking plate for osteoporotic distal femur fractures.
    Park KC; Lim SJ; Song YS; Hwang KT
    Orthop Traumatol Surg Res; 2017 Dec; 103(8):1201-1204. PubMed ID: 28935593
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Treatment of type B periprosthetic femur fractures with curved non-locking plate with eccentric holes: Retrospective study of 43 patients with minimum 1-year follow-up.
    Lunebourg A; Mouhsine E; Cherix S; Ollivier M; Chevalley F; Wettstein M
    Orthop Traumatol Surg Res; 2015 May; 101(3):277-82. PubMed ID: 25817903
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis.
    Shin YS; Kim HJ; Lee DH
    Knee Surg Sports Traumatol Arthrosc; 2017 Sep; 25(9):2921-2928. PubMed ID: 26897137
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Are proximal screws necessary for osteosynthesis of stable-stem periprosthetic femoral fractures fixed with non-locking plate and cable?
    Yang TC; Tzeng YH; Wang CS; Lin CC; Chang MC; Chiang CC
    Injury; 2019 Oct; 50(10):1739-1744. PubMed ID: 31182231
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Locking plate fixation of periprosthetic femur fractures with and without cerclage wires.
    Ebraheim NA; Sochacki KR; Liu X; Hirschfeld AG; Liu J
    Orthop Surg; 2013 Aug; 5(3):183-7. PubMed ID: 24002835
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 43.