These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 26765556)

  • 1. Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial.
    van Os S; Cheung PY; Kushniruk K; O'Reilly M; Aziz K; Schmölzer GM
    J Perinatol; 2016 May; 36(5):370-5. PubMed ID: 26765556
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of gas flow waves for endotracheal tube placement in an ovine model of neonatal resuscitation.
    Schmölzer GM; Hooper SB; Crossley KJ; Allison BJ; Morley CJ; Davis PG
    Resuscitation; 2010 Jun; 81(6):737-41. PubMed ID: 20334964
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device.
    Ornato JP; Shipley JB; Racht EM; Slovis CM; Wrenn KD; Pepe PE; Almeida SL; Ginger VF; Fotre TV
    Ann Emerg Med; 1992 May; 21(5):518-23. PubMed ID: 1570906
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validity of a disposable end-tidal CO2 detector in verifying endotracheal tube placement in infants and children.
    Bhende MS; Thompson AE; Cook DR; Saville AL
    Ann Emerg Med; 1992 Feb; 21(2):142-5. PubMed ID: 1739199
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tidal volume monitoring during initial resuscitation of extremely prematurely born infants.
    Hunt KA; Murthy V; Bhat P; Fox GF; Campbell ME; Milner AD; Greenough A
    J Perinat Med; 2019 Aug; 47(6):665-670. PubMed ID: 31103996
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of exhaled carbon dioxide following intubation during resuscitation at delivery.
    Hunt KA; Yamada Y; Murthy V; Srihari Bhat P; Campbell M; Fox GF; Milner AD; Greenough A
    Arch Dis Child Fetal Neonatal Ed; 2019 Mar; 104(2):F187-F191. PubMed ID: 29550769
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of an end-tidal CO2 detector during pediatric cardiopulmonary resuscitation.
    Bhende MS; Thompson AE
    Pediatrics; 1995 Mar; 95(3):395-9. PubMed ID: 7862479
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The esophageal detector device: a rapid and accurate method for assessing tracheal versus esophageal intubation in a porcine model.
    Foutch RG; Magelssen MD; MacMillan JG
    Ann Emerg Med; 1992 Sep; 21(9):1073-6. PubMed ID: 1514718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of flow waves and colorimetric CO2 detector for endotracheal tube placement during neonatal resuscitation.
    Schmölzer GM; Poulton DA; Dawson JA; Kamlin CO; Morley CJ; Davis PG
    Resuscitation; 2011 Mar; 82(3):307-12. PubMed ID: 21167628
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation.
    Bozeman WP; Hexter D; Liang HK; Kelen GD
    Ann Emerg Med; 1996 May; 27(5):595-9. PubMed ID: 8629780
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The pediatric disposable end-tidal carbon dioxide detector role in endotracheal intubation in newborns.
    Aziz HF; Martin JB; Moore JJ
    J Perinatol; 1999 Mar; 19(2):110-3. PubMed ID: 10642970
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validity of a disposable end-tidal carbon dioxide detector in verifying endotracheal tube position in piglets.
    Bhende MS; Thompson AE; Howland DF
    Crit Care Med; 1991 Apr; 19(4):566-8. PubMed ID: 1902156
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prematurely born infants' response to resuscitation via an endotracheal tube or a face mask.
    Murthy V; D'Costa W; Shah R; Fox GF; Campbell ME; Milner AD; Greenough A
    Early Hum Dev; 2015 Mar; 91(3):235-8. PubMed ID: 25706318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: pediatric basic life support.
    American Heart Association
    Pediatrics; 2006 May; 117(5):e989-1004. PubMed ID: 16651298
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects.
    O'Donnell CP; Kamlin CO; Davis PG; Morley CJ
    Pediatrics; 2006 Jan; 117(1):e16-21. PubMed ID: 16396845
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of a colorimetric end-tidal CO2 detector and an esophageal aspiration device for verifying endotracheal tube placement in the prehospital setting: a six-month experience.
    Schaller RJ; Huff JS; Zahn A
    Prehosp Disaster Med; 1997; 12(1):57-63. PubMed ID: 10166376
    [TBL] [Abstract][Full Text] [Related]  

  • 17. End tidal carbon dioxide monitoring in prehospital and retrieval medicine: a review.
    Donald MJ; Paterson B
    Emerg Med J; 2006 Sep; 23(9):728-30. PubMed ID: 16921096
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of end-tidal carbon dioxide monitoring to confirm endotracheal tube placement in adult and paediatric intensive care units in Australia and New Zealand.
    Erasmus PD
    Anaesth Intensive Care; 2004 Oct; 32(5):672-5. PubMed ID: 15535493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Colorimetric end-tidal carbon dioxide detectors in the delivery room: strengths and limitations. A case report.
    Kamlin CO; O'Donnell CP; Davis PG; Morley CJ
    J Pediatr; 2005 Oct; 147(4):547-8. PubMed ID: 16227046
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Techniques to ascertain correct endotracheal tube placement in neonates.
    Schmölzer GM; Roehr CC
    Cochrane Database Syst Rev; 2014 Sep; (9):CD010221. PubMed ID: 25217732
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.