These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 26774646)
1. Constant-variable flip angles for hyperpolarized media MRI. Deng H; Zhong J; Ruan W; Chen X; Sun X; Ye C; Liu M; Zhou X J Magn Reson; 2016 Feb; 263():92-100. PubMed ID: 26774646 [TBL] [Abstract][Full Text] [Related]
3. Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold. Zhong J; Ruan W; Han Y; Sun X; Ye C; Zhou X Sci Rep; 2016 May; 6():25854. PubMed ID: 27169670 [TBL] [Abstract][Full Text] [Related]
4. Abdominal T2-Weighted Imaging and T2 Mapping Using a Variable Flip Angle Radial Turbo Spin-Echo Technique. Keerthivasan MB; Galons JP; Johnson K; Umapathy L; Martin DR; Bilgin A; Altbach MI J Magn Reson Imaging; 2022 Jan; 55(1):289-300. PubMed ID: 34254382 [TBL] [Abstract][Full Text] [Related]
5. Optimizing SNR for multi-metabolite hyperpolarized carbon-13 MRI using a hybrid flip-angle scheme. Smith LM; Wade TP; Friesen-Waldner LJ; McKenzie CA Magn Reson Med; 2020 Sep; 84(3):1510-1517. PubMed ID: 32011018 [TBL] [Abstract][Full Text] [Related]
6. Motion-robust, high-SNR liver fat quantification using a 2D sequential acquisition with a variable flip angle approach. Zhao R; Zhang Y; Wang X; Colgan TJ; Rehm JL; Reeder SB; Johnson KM; Hernando D Magn Reson Med; 2020 Oct; 84(4):2004-2017. PubMed ID: 32243665 [TBL] [Abstract][Full Text] [Related]
7. Considering low-rank, sparse and gas-inflow effects constraints for accelerated pulmonary dynamic hyperpolarized Xiao S; Deng H; Duan C; Xie J; Zhang H; Sun X; Ye C; Zhou X J Magn Reson; 2018 May; 290():29-37. PubMed ID: 29549792 [TBL] [Abstract][Full Text] [Related]
15. Technical Note: The effect of 2D excitation profile on T1 measurement accuracy using the variable flip angle method with an average flip angle assumption. Svedin BT; Parker DL Med Phys; 2017 Nov; 44(11):5930-5937. PubMed ID: 28796308 [TBL] [Abstract][Full Text] [Related]
16. k-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI: spatial resolution and signal-to-noise ratio considerations. Wild JM; Paley MN; Viallon M; Schreiber WG; van Beek EJ; Griffiths PD Magn Reson Med; 2002 Apr; 47(4):687-95. PubMed ID: 11948729 [TBL] [Abstract][Full Text] [Related]
17. Flip-angle measurement by magnetization inversion: Calibration of magnetization nutation angle in hyperpolarized (3) He magnetic resonance imaging lung experiments. Rivoire J; Terekhov M; Meise FM; Gast K; Salhi Z; Schreiber LM Magn Reson Med; 2011 Feb; 65(2):399-408. PubMed ID: 20882641 [TBL] [Abstract][Full Text] [Related]
18. Design and use of variable flip angle schedules in transient balanced SSFP subtractive imaging. Smith T; Zun Z; Wong EC; Nayak KS Magn Reson Med; 2010 Feb; 63(2):537-42. PubMed ID: 20099336 [TBL] [Abstract][Full Text] [Related]