102 related articles for article (PubMed ID: 26776501)
1. IEC 61267: Feasibility of type 1100 aluminium and a copper/aluminium combination for RQA beam qualities.
Leong DL; Rainford L; Zhao W; Brennan PC
Phys Med; 2016 Jan; 32(1):141-9. PubMed ID: 26776501
[TBL] [Abstract][Full Text] [Related]
2. Effects of aluminum-copper alloy filtration on photon spectra, air kerma rate and image contrast.
Gonçalves A; Rollo JM; Gonçalves M; Haiter Neto F; Bóscolo FN
Braz Dent J; 2004; 15(3):214-9. PubMed ID: 15798826
[TBL] [Abstract][Full Text] [Related]
3. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
[TBL] [Abstract][Full Text] [Related]
4. Equivalent thicknesses of beam hardening filters consisting of aluminium, copper, Al/Cu and Al/Gold combinations and plumbiferous acrylic for 40 to 150 kVp diagnostic spectra.
Homolka P; Figl M
J Radiol Prot; 2018 Dec; 38(4):1269-1283. PubMed ID: 30115815
[TBL] [Abstract][Full Text] [Related]
5. Effect of X-ray beam quality on determination of exposure index.
Yasumatsu S; Tanaka N; Iwase K; Shimizu Y; Morishita J
Radiol Phys Technol; 2016 Jan; 9(1):109-15. PubMed ID: 26619973
[TBL] [Abstract][Full Text] [Related]
6. [Study on the method for the determination of Fe, Si, Cu, Mg, Mn, Ni, Zn, Ti, Cr, Sr in aluminium alloy by ICP-AES].
Zhong ZG; Bian QZ; Zheng JG; Chen PL; Liu CH; Wei XY
Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Feb; 22(1):83-5. PubMed ID: 12940035
[TBL] [Abstract][Full Text] [Related]
7. A simulation-based study on the influence of beam hardening in X-ray computed tomography for dimensional metrology.
Lifton JJ; Malcolm AA; McBride JW
J Xray Sci Technol; 2015; 23(1):65-82. PubMed ID: 25567408
[TBL] [Abstract][Full Text] [Related]
8. Recovery of aluminium, nickel-copper alloys and salts from spent fluorescent lamps.
Rabah MA
Waste Manag; 2004; 24(2):119-26. PubMed ID: 14761750
[TBL] [Abstract][Full Text] [Related]
9. Measurement of the detective quantum efficiency in digital detectors consistent with the IEC 62220-1 standard: Practical considerations regarding the choice of filter material.
Ranger NT; Samei E; Dobbins JT; Ravin CE
Med Phys; 2005 Jul; 32(7Part1):2305-2311. PubMed ID: 28493576
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the quantitative capability of a home-made cone-beam micro computed tomography system.
Chueh HS; Tsai WK; Fu HM; Chen JC
Comput Med Imaging Graph; 2006; 30(6-7):349-55. PubMed ID: 17067784
[TBL] [Abstract][Full Text] [Related]
11. Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector.
Kitagawa H; Farman AG
Dentomaxillofac Radiol; 2004 Jan; 33(1):21-4. PubMed ID: 15140818
[TBL] [Abstract][Full Text] [Related]
12. The relationship between pixel value and beam quality in photostimulable phosphor imaging.
Tucker DM; Rezentes PS
Med Phys; 1997 Jun; 24(6):887-93. PubMed ID: 9198024
[TBL] [Abstract][Full Text] [Related]
13. [The measurement of the dynamic range of digital systems for visualizing x-ray images].
Kozlovskiĭ EB
Med Tekh; 2000; (5):26-8. PubMed ID: 11076361
[TBL] [Abstract][Full Text] [Related]
14. Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners.
Abella M; Vaquero JJ; Sisniega A; Pascau J; Udías A; García V; Vidal I; Desco M
Comput Methods Programs Biomed; 2012 Aug; 107(2):218-32. PubMed ID: 21908068
[TBL] [Abstract][Full Text] [Related]
15. A simple method for evaluation of half-value layer variation in CT equipment.
Maia AF; Caldas LV
Phys Med Biol; 2006 Mar; 51(6):1595-601. PubMed ID: 16510965
[TBL] [Abstract][Full Text] [Related]
16. Effect of sample structure on reconstruction quality in computed tomography.
Cao M; Zhang HB; Li C; Nishi R
Rev Sci Instrum; 2009 Feb; 80(2):026104. PubMed ID: 19256680
[TBL] [Abstract][Full Text] [Related]
17. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1.
Illers H; Buhr E; Hoeschen C
Radiat Prot Dosimetry; 2005; 114(1-3):39-44. PubMed ID: 15933079
[TBL] [Abstract][Full Text] [Related]
18. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.
Koike M; Hummel SK; Ball JD; Okabe T
J Prosthet Dent; 2012 Jun; 107(6):393-9. PubMed ID: 22633596
[TBL] [Abstract][Full Text] [Related]
19. (HP)Ge Measurement of spectra for diagnostic X-ray beams.
Nogueira MS; Mota HC; Campos LL
Radiat Prot Dosimetry; 2004; 111(1):105-10. PubMed ID: 15367779
[TBL] [Abstract][Full Text] [Related]
20. [Effect of casting techniques on castability of copper-aluminum alloys].
Scaranelo RM; Bombonatti PE; de Barros LE; Pellizzer AJ
Rev Odontol UNESP; 1990; 19(1):211-6. PubMed ID: 2099550
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]