These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

727 related articles for article (PubMed ID: 26776939)

  • 21. Evaluation of the Amount of Root Canal Dentin Removed and Apical Transportation Occurrence after Instrumentation with ProTaper Next, OneShape, and EdgeFile Rotary Systems.
    Yılmaz F; Eren İ; Eren H; Badi MA; Ocak M; Çelik HH
    J Endod; 2020 May; 46(5):662-667. PubMed ID: 32151482
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.
    Wu J; Lei G; Yan M; Yu Y; Yu J; Zhang G
    J Endod; 2011 Jun; 37(6):758-63. PubMed ID: 21787484
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Lack of causal relationship between dentinal microcracks and root canal preparation with reciprocation systems.
    De-Deus G; Silva EJ; Marins J; Souza E; Neves Ade A; Gonçalves Belladonna F; Alves H; Lopes RT; Versiani MA
    J Endod; 2014 Sep; 40(9):1447-50. PubMed ID: 25146030
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A Micro-computed Tomographic Assessment of Root Canal Preparation with a Novel Instrument, TRUShape, in Mesial Roots of Mandibular Molars.
    Peters OA; Arias A; Paqué F
    J Endod; 2015 Sep; 41(9):1545-50. PubMed ID: 26238528
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stress generation during self-adjusting file movement: minimally invasive instrumentation.
    Kim HC; Sung SY; Ha JH; Solomonov M; Lee JM; Lee CJ; Kim BM
    J Endod; 2013 Dec; 39(12):1572-5. PubMed ID: 24238449
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals.
    Wu H; Peng C; Bai Y; Hu X; Wang L; Li C
    BMC Oral Health; 2015 Mar; 15():27. PubMed ID: 25886847
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparative study of 6 rotary nickel-titanium systems and hand instrumentation for root canal preparation in severely curved root canals of extracted teeth.
    Celik D; Taşdemir T; Er K
    J Endod; 2013 Feb; 39(2):278-82. PubMed ID: 23321246
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.
    Paqué F; Zehnder M; De-Deus G
    J Endod; 2011 Oct; 37(10):1394-7. PubMed ID: 21924189
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Changes in Geometry and Transportation of Root Canals with Severe Curvature Prepared by Different Heat-treated Nickel-titanium Instruments: A Micro-computed Tomographic Study.
    Filizola de Oliveira DJ; Leoni GB; da Silva Goulart R; Sousa-Neto MD; Silva Sousa YTC; Silva RG
    J Endod; 2019 Jun; 45(6):768-773. PubMed ID: 30954280
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Micro-computed tomography evaluation of the preparation of long oval root canals in mandibular molars with the self-adjusting file.
    Paqué F; Peters OA
    J Endod; 2011 Apr; 37(4):517-21. PubMed ID: 21419301
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.
    Peru M; Peru C; Mannocci F; Sherriff M; Buchanan LS; Pitt Ford TR
    Eur J Dent Educ; 2006 Feb; 10(1):52-9. PubMed ID: 16436085
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Influence of Contracted Endodontic Access on Root Canal Geometry: An In Vitro Study.
    Alovisi M; Pasqualini D; Musso E; Bobbio E; Giuliano C; Mancino D; Scotti N; Berutti E
    J Endod; 2018 Apr; 44(4):614-620. PubMed ID: 29336881
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accumulated hard tissue debris produced during reciprocating and rotary nickel-titanium canal preparation.
    De-Deus G; Marins J; Silva EJ; Souza E; Belladonna FG; Reis C; Machado AS; Lopes RT; Versiani MA; Paciornik S; Neves AA
    J Endod; 2015 May; 41(5):676-81. PubMed ID: 25670245
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Micro-computed Tomographic Assessment and Comparative Study of the Shaping Ability of 6 Nickel-Titanium Files: An In Vitro Study.
    Pérez Morales MLN; González Sánchez JA; Olivieri JG; Elmsmari F; Salmon P; Jaramillo DE; Terol FD
    J Endod; 2021 May; 47(5):812-819. PubMed ID: 33549630
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.
    Kim HC; Lee MH; Yum J; Versluis A; Lee CJ; Kim BM
    J Endod; 2010 Jul; 36(7):1195-9. PubMed ID: 20630298
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals.
    Alves Vde O; Bueno CE; Cunha RS; Pinheiro SL; Fontana CE; de Martin AS
    J Endod; 2012 Jan; 38(1):117-20. PubMed ID: 22152634
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments.
    Paqué F; Musch U; Hülsmann M
    Int Endod J; 2005 Jan; 38(1):8-16. PubMed ID: 15606817
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Efficacy of reciprocating instruments for removing filling material in curved canals obturated with a single-cone technique: a micro-computed tomographic analysis.
    Fruchi Lde C; Ordinola-Zapata R; Cavenago BC; Hungaro Duarte MA; Bueno CE; De Martin AS
    J Endod; 2014 Jul; 40(7):1000-4. PubMed ID: 24935552
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparing canal transportation and centering ability of endosequence and vortex rotary files by using micro-computed tomography.
    Yamamura B; Cox TC; Heddaya B; Flake NM; Johnson JD; Paranjpe A
    J Endod; 2012 Aug; 38(8):1121-5. PubMed ID: 22794219
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Changes in centring and shaping ability using three nickel–titanium instrumentation techniques analysed by micro-computed tomography (μCT).
    Stern S; Patel S; Foschi F; Sherriff M; Mannocci F
    Int Endod J; 2012 Jun; 45(6):514-23. PubMed ID: 22625863
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 37.