These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 26782193)

  • 1. Muscle Oxygenation During Running Assessed by Broad Band NIRS.
    Steimers A; Vafiadou M; Koukourakis G; Geraskin D; Neary P; Kohl-Bareis M
    Adv Exp Med Biol; 2016; 876():41-47. PubMed ID: 26782193
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tissue oxygenation during exercise measured with NIRS: reproducibility and influence of wavelengths.
    Gerz E; Geraskin D; Franke J; Platen P; Steimers A; Kohl-Bareis M
    Adv Exp Med Biol; 2013; 789():171-177. PubMed ID: 23852492
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of portable NIRS to measure muscle oxygenation and haemodynamics during a repeated sprint running test.
    Jones B; Hesford CM; Cooper CE
    Adv Exp Med Biol; 2013; 789():185-191. PubMed ID: 23852494
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Near infrared spectroscopy and changes in skeletal muscle oxygenation during incremental exercise in chronic heart failure: a comparison with healthy subjects.
    Belardinelli R; Georgiou D; Barstow TJ
    G Ital Cardiol; 1995 Jun; 25(6):715-24. PubMed ID: 7649420
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of near-infrared spectroscopy in understanding skeletal muscle physiology: recent developments.
    Ferrari M; Muthalib M; Quaresima V
    Philos Trans A Math Phys Eng Sci; 2011 Nov; 369(1955):4577-90. PubMed ID: 22006907
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans.
    Hiroyuki H; Hamaoka T; Sako T; Nishio S; Kime R; Murakami M; Katsumura T
    Eur J Appl Physiol; 2002 Aug; 87(4-5):343-9. PubMed ID: 12172872
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New Insights into Mechanical, Metabolic and Muscle Oxygenation Signals During and After High-Intensity Tethered Running.
    Manchado-Gobatto FB; Marostegan AB; Rasteiro FM; Cirino C; Cruz JP; Moreno MA; Gobatto CA
    Sci Rep; 2020 Apr; 10(1):6336. PubMed ID: 32286408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of electrical stimulation and voluntary exercise on muscle oxygenation assessed by NIRS.
    Hirata K; Hara T; Oshima Y; Yoshikawa T; Fujimoto S
    Osaka City Med J; 2006 Dec; 52(2):67-78. PubMed ID: 17330394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hypoxia affects tissue oxygenation differently in the thigh and calf muscles during incremental running.
    Osawa T; Arimitsu T; Takahashi H
    Eur J Appl Physiol; 2017 Oct; 117(10):2057-2064. PubMed ID: 28819691
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A modular NIRS system for clinical measurement of impaired skeletal muscle oxygenation.
    Wariar R; Gaffke JN; Haller RG; Bertocci LA
    J Appl Physiol (1985); 2000 Jan; 88(1):315-25. PubMed ID: 10642395
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Effects of Limb Elevation on Muscle Oxygen Saturation: A Near-Infrared Spectroscopy Study in Humans.
    Palanca AA; Yang A; Bishop JA
    PM R; 2016 Mar; 8(3):221-4. PubMed ID: 26261022
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Muscle Oximetry in Sports Science: A Systematic Review.
    Perrey S; Ferrari M
    Sports Med; 2018 Mar; 48(3):597-616. PubMed ID: 29177977
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of skeletal muscle oxygenation and fuel use in sustained continuous and intermittent exercise.
    Christmass MA; Dawson B; Passeretto P; Arthur PG
    Eur J Appl Physiol Occup Physiol; 1999 Oct; 80(5):423-35. PubMed ID: 10502076
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise.
    Austin KG; Daigle KA; Patterson P; Cowman J; Chelland S; Haymes EM
    Res Q Exerc Sport; 2005 Dec; 76(4):440-9. PubMed ID: 16739682
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of work and recovery duration on skeletal muscle oxygenation and fuel use during sustained intermittent exercise.
    Christmass MA; Dawson B; Arthur PG
    Eur J Appl Physiol Occup Physiol; 1999 Oct; 80(5):436-47. PubMed ID: 10502077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous quantitative assessment of cerebral physiology using respiratory-calibrated MRI and near-infrared spectroscopy in healthy adults.
    Alderliesten T; De Vis JB; Lemmers PM; van Bel F; Benders MJ; Hendrikse J; Petersen ET
    Neuroimage; 2014 Jan; 85 Pt 1():255-63. PubMed ID: 23859925
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of assuming constant optical scattering on measurements of muscle oxygenation by near-infrared spectroscopy during exercise.
    Ferreira LF; Hueber DM; Barstow TJ
    J Appl Physiol (1985); 2007 Jan; 102(1):358-67. PubMed ID: 17023569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Muscle oxygen saturation measured using "cyclic NIR signals" during exercise.
    Leung TS; Wittekind A; Binzoni T; Beneke R; Cooper CE; Elwell CE
    Adv Exp Med Biol; 2010; 662():183-9. PubMed ID: 20204790
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of adipose tissue on spatially resolved near-infrared spectroscopy derived skeletal muscle oxygenation: the extent of the problem.
    Niemeijer VM; Jansen JP; van Dijk T; Spee RF; Meijer EJ; Kemps HM; Wijn PF
    Physiol Meas; 2017 Mar; 38(3):539-554. PubMed ID: 28151429
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a textile-based near infrared spectroscopy system in calf muscle oxygenation measurements.
    Nasseri N; Zysset C; Büthe L; Kleiser S; Tröster G; Wolf M
    Adv Exp Med Biol; 2014; 812():355-360. PubMed ID: 24729254
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.