  • 1. Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities.
    Rodbard D
    Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S3-S13. PubMed ID: 26784127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.
    Kropff J; DeVries JH
    Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S253-63. PubMed ID: 26784131
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring.
    Kovatchev BP; Patek SD; Ortiz EA; Breton MD
    Diabetes Technol Ther; 2015 Mar; 17(3):177-86. PubMed ID: 25436913
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Benefits and limitations of continuous glucose monitoring in type 1 diabetes.
    Stone JY; Bailey TS
    Expert Rev Endocrinol Metab; 2020 Jan; 15(1):41-49. PubMed ID: 31928104
    [No Abstract]   [Full Text] [Related]  

  • 6. The effectiveness of continuous subcutaneous insulin pumps with continuous glucose monitoring in outpatient adolescents with type 1 diabetes: A systematic review.
    Matsuda E; Brennan P
    JBI Libr Syst Rev; 2012; 10(42 Suppl):1-10. PubMed ID: 27820140
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous Glucose Monitoring Integration in Clinical Practice: A Stepped Guide to Data Review and Interpretation.
    Aleppo G; Webb K
    J Diabetes Sci Technol; 2019 Jul; 13(4):664-673. PubMed ID: 30453772
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diabetes Technology: Monitoring, Analytics, and Optimal Control.
    Kovatchev B
    Cold Spring Harb Perspect Med; 2019 Jun; 9(6):. PubMed ID: 30126835
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hypo- and Hyperglycemic Alarms: Devices and Algorithms.
    Howsmon D; Bequette BW
    J Diabetes Sci Technol; 2015 Apr; 9(5):1126-37. PubMed ID: 25931581
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of Inpatient CGM: Comparison to Standard of Care.
    Price C; Ditton G; Russell GB; Aloi J
    J Diabetes Sci Technol; 2023 Mar; 17(2):329-335. PubMed ID: 34911384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypoglycemia prevention via pump attenuation and red-yellow-green "traffic" lights using continuous glucose monitoring and insulin pump data.
    Hughes CS; Patek SD; Breton MD; Kovatchev BP
    J Diabetes Sci Technol; 2010 Sep; 4(5):1146-55. PubMed ID: 20920434
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessing performance of closed-loop insulin delivery systems by continuous glucose monitoring: drawbacks and way forward.
    Hovorka R; Nodale M; Haidar A; Wilinska ME
    Diabetes Technol Ther; 2013 Jan; 15(1):4-12. PubMed ID: 23046396
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sensitivity of the Predictive Hypoglycemia Minimizer System to the Algorithm Aggressiveness Factor.
    Finan DA; Dassau E; Breton MD; Patek SD; McCann TW; Kovatchev BP; Doyle FJ; Levy BL; Venugopalan R
    J Diabetes Sci Technol; 2015 Jun; 10(1):104-10. PubMed ID: 26134834
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes: A Randomized Clinical Trial.
    Pratley RE; Kanapka LG; Rickels MR; Ahmann A; Aleppo G; Beck R; Bhargava A; Bode BW; Carlson A; Chaytor NS; Fox DS; Goland R; Hirsch IB; Kruger D; Kudva YC; Levy C; McGill JB; Peters A; Philipson L; Philis-Tsimikas A; Pop-Busui R; Shah VN; Thompson M; Vendrame F; Verdejo A; Weinstock RS; Young L; Miller KM;
    JAMA; 2020 Jun; 323(23):2397-2406. PubMed ID: 32543682
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Association of Real-time Continuous Glucose Monitoring With Glycemic Control and Acute Metabolic Events Among Patients With Insulin-Treated Diabetes.
    Karter AJ; Parker MM; Moffet HH; Gilliam LK; Dlott R
    JAMA; 2021 Jun; 325(22):2273-2284. PubMed ID: 34077502
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perioperative Considerations for Evolving Artificial Pancreas Devices.
    Long MT; Coursin DB; Rice MJ
    Anesth Analg; 2019 May; 128(5):902-906. PubMed ID: 30198923
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diabetes technology and treatments in the paediatric age group.
    Shalitin S; Peter Chase H
    Int J Clin Pract Suppl; 2011 Feb; (170):76-82. PubMed ID: 21323816
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nocturnal Hypoglycemia in the Era of Continuous Glucose Monitoring.
    Kulzer B; Freckmann G; Ziegler R; Schnell O; Glatzer T; Heinemann L
    J Diabetes Sci Technol; 2024 Sep; 18(5):1052-1060. PubMed ID: 39158988
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes.
    Slattery D; Choudhary P
    Diabetes Technol Ther; 2017 May; 19(S2):S55-S61. PubMed ID: 28541131
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management.
    Mian Z; Hermayer KL; Jenkins A
    Am J Med Sci; 2019 Nov; 358(5):332-339. PubMed ID: 31402042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]