These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

300 related articles for article (PubMed ID: 26787024)

  • 1. Diagnostic Accuracy of Diffusion Weighted Magnetic Resonance Imaging in the Detection of Myometrial Invasion in Endometrial Carcinoma.
    Taufiq M; Masroor I; Hussain Z
    J Coll Physicians Surg Pak; 2016 Jan; 26(1):13-7. PubMed ID: 26787024
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnostic efficacy of diffusion-weighted MRI for pre-operative assessment of myometrial and cervical invasion and pelvic lymph node metastasis in endometrial carcinoma.
    Koplay M; Dogan NU; Erdogan H; Sivri M; Erol C; Nayman A; Karabagli P; Paksoy Y; Celik C
    J Med Imaging Radiat Oncol; 2014 Oct; 58(5):538-46; quiz 648. PubMed ID: 25046775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Usefulness of DWI in preoperative assessment of deep myometrial invasion in patients with endometrial carcinoma: a systematic review and meta-analysis.
    Das SK; Niu XK; Wang JL; Zeng LC; Wang WX; Bhetuwal A; Yang HF
    Cancer Imaging; 2014 Nov; 14(1):32. PubMed ID: 25608571
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preoperative Evaluation of Myometrial Invasion in Endometrial Carcinoma: Prospective Intra-individual Comparison of Magnetic Resonance Volumetry, Diffusion-weighted and Dynamic Contrast-enhanced Magnetic Resonance Imaging.
    Thieme SF; Collettini F; Sehouli J; Biocca L; Lella A; Wagner M; Almuheimid J; Plett H; Muallem MZ
    Anticancer Res; 2018 Aug; 38(8):4813-4817. PubMed ID: 30061253
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of myometrial invasion in endometrial cancer: comparison of diffusion-weighted magnetic resonance and intraoperative frozen sections.
    Gallego JC; Porta A; Pardo MC; Fernández C
    Abdom Imaging; 2014 Oct; 39(5):1021-6. PubMed ID: 24699937
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of depth of myometrial invasion and overall staging in endometrial cancer: comparison of diffusion-weighted and dynamic contrast-enhanced MR imaging.
    Beddy P; Moyle P; Kataoka M; Yamamoto AK; Joubert I; Lomas D; Crawford R; Sala E
    Radiology; 2012 Feb; 262(2):530-7. PubMed ID: 22114239
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T.
    Rechichi G; Galimberti S; Signorelli M; Perego P; Valsecchi MG; Sironi S
    Eur Radiol; 2010 Mar; 20(3):754-62. PubMed ID: 19727740
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluating Myometrial Invasion in Endometrial Cancer: Comparison of Reduced Field-of-view Diffusion-weighted Imaging and Dynamic Contrast-enhanced MR Imaging.
    Takeuchi M; Matsuzaki K; Harada M
    Magn Reson Med Sci; 2018 Jan; 17(1):28-34. PubMed ID: 28515411
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined subjective and quantitative analysis of magnetic resonance images could improve the diagnostic performance of deep myometrial invasion in endometrial cancer.
    Deng L; Wang QP; Yan R; Yu N; Bai L; Duan XY; Guo YM
    Clin Imaging; 2017; 43():69-73. PubMed ID: 28232207
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diffusion-weighted magnetic resonance imaging of endometrial cancer: differentiation from benign endometrial lesions and preoperative assessment of myometrial invasion.
    Takeuchi M; Matsuzaki K; Nishitani H
    Acta Radiol; 2009 Oct; 50(8):947-53. PubMed ID: 19724949
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preoperative Assessment of Myometrial Invasion in Endometrial Cancer by 3D Ultrasound and Diffusion-Weighted Magnetic Resonance Imaging: A Comparative Study.
    Rodríguez-Trujillo A; Martínez-Serrano MJ; Martínez-Román S; Martí C; Buñesch L; Nicolau C; Pahisa J
    Int J Gynecol Cancer; 2016 Jul; 26(6):1105-10. PubMed ID: 27177278
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of menopausal status on diagnostic accuracy of myometrial invasion in endometrial cancer: diffusion-weighted and dynamic contrast-enhanced MRI at 3 T.
    Lin G; Huang YT; Chao A; Ng KK; Yang LY; Ng SH; Lai CH
    Clin Radiol; 2015 Nov; 70(11):1260-8. PubMed ID: 26233681
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myometrial invasion in endometrial cancer: diagnostic accuracy of diffusion-weighted 3.0-T MR imaging--initial experience.
    Lin G; Ng KK; Chang CJ; Wang JJ; Ho KC; Yen TC; Wu TI; Wang CC; Chen YR; Huang YT; Ng SH; Jung SM; Chang TC; Lai CH
    Radiology; 2009 Mar; 250(3):784-92. PubMed ID: 19244045
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study.
    Ota T; Hori M; Onishi H; Sakane M; Tsuboyama T; Tatsumi M; Nakamoto A; Kimura T; Narumi Y; Tomiyama N
    Eur Radiol; 2017 Dec; 27(12):5225-5235. PubMed ID: 28674966
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of myometrial invasion by endometrial carcinoma: transvaginal sonography vs contrast-enhanced MR imaging.
    Yamashita Y; Mizutani H; Torashima M; Takahashi M; Miyazaki K; Okamura H; Ushijima H; Ohtake H; Tokunaga T
    AJR Am J Roentgenol; 1993 Sep; 161(3):595-9. PubMed ID: 8352114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The accuracy of magnetic resonance imaging for preoperative deep myometrium assessment in endometrial cancer.
    Wu WJ; Yu MS; Su HY; Lin KS; Lu KL; Hwang KS
    Taiwan J Obstet Gynecol; 2013 Jun; 52(2):210-4. PubMed ID: 23915853
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Myometrial invasion by endometrial carcinoma: evaluation with 3.0T MR imaging.
    Kaneda S; Fujii S; Fukunaga T; Kakite S; Kaminou T; Kigawa J; Harada T; Ogawa T
    Abdom Imaging; 2011 Oct; 36(5):612-8. PubMed ID: 21479805
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of diffusion tensor imaging in assessing superficial myometrial invasion by endometrial carcinoma: a preliminary study.
    Zhang L; Liu A; Zhang T; Song Q; Wei Q; Wang H
    Acta Radiol; 2015 Oct; 56(10):1273-80. PubMed ID: 25332442
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preoperative prediction of deep myometrial invasion and tumor grade for stage I endometrioid adenocarcinoma: a simple method of measurement on DWI.
    Yan B; Liang X; Zhao T; Niu C; Ding C; Liu W
    Eur Radiol; 2019 Feb; 29(2):838-848. PubMed ID: 30039225
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MRI evaluation of myometrial invasion by endometrial carcinoma. Comparison between fast-spin-echo T2w and coronal-FMPSPGR Gadolinium-Dota-enhanced sequences.
    Nasi F; Fiocchi F; Pecchi A; Rivasi F; Torricelli P
    Radiol Med; 2005 Sep; 110(3):199-210. PubMed ID: 16200042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.