These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 267913)

  • 1. [The loss of volume in modern respirators during change of compliance and resistance (author's transl)].
    Ehehalt V; Kluge E; Mottner J
    Prakt Anaesth; 1977 Apr; 12(2):138-44. PubMed ID: 267913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The importance of an endexspiratory plateau in respirators (author's transl)].
    Schlimgen R
    Prakt Anaesth; 1977 Dec; 12(6):505-10. PubMed ID: 271304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Mechanics of breathing during anaesthesia with controlled ventilation by means of the engström ecs 2000 respirator (author's transl)].
    Osswald PM; Klose R; Hartung HJ; Jaminet M
    Anasth Intensivther Notfallmed; 1981 Feb; 16(1):22-4. PubMed ID: 6786131
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
    Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
    Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The appraisal of role of power in end-inspiratory plateau (EIP) on ventilator, and airway dynamics (author's transl)].
    Mima M; Imanishi T; Taguchi H
    Kokyu To Junkan; 1981 Sep; 29(9):949-55. PubMed ID: 6948334
    [No Abstract]   [Full Text] [Related]  

  • 7. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
    Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
    Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using conventional infant ventilators at unconventional rates.
    Boros SJ; Bing DR; Mammel MC; Hagen E; Gordon MJ
    Pediatrics; 1984 Oct; 74(4):487-92. PubMed ID: 6384912
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Respiratory mechanics derived from signals in the ventilator circuit.
    Lucangelo U; Bernabé F; Blanch L
    Respir Care; 2005 Jan; 50(1):55-65; discussion 65-7. PubMed ID: 15636645
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Effects of compliance of a volume limited ventilator on the actual inspiratory power and the insufflating gas volume (author's transl)].
    Mima M; Imanishi T; Fujise K
    Masui; 1978 Apr; 27(4):390-6. PubMed ID: 274589
    [No Abstract]   [Full Text] [Related]  

  • 11. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect on work of breathing of different continuous positive airway pressure devices evaluated in a premature neonatal lung model.
    Nikischin W; Petridis M; Noeske J; Spengler D; von Bismarck P
    Pediatr Crit Care Med; 2011 Nov; 12(6):e376-82. PubMed ID: 21499172
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Physiopathology of acute respiratory failure in COPD and asthma].
    Mergoni M; Rossi A
    Minerva Anestesiol; 2001 Apr; 67(4):198-205. PubMed ID: 11376510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Measurement of bronchopulmonary elastance and airway resistance: comparison between common methods and automatic continuous measurement by the system AUPREM (author's transl)].
    Schlick W; Fitzal S; Benzer H; Geyer A; Mulac C; Schmid P
    Anaesthesist; 1976 Aug; 25(8):393-7. PubMed ID: 949109
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The compliance-volume relationship in healthy persons and in cases of fibrosis of the lungs and pulmonary emphysema (author's transl)].
    Bugalho de Almeida AA; Telhada F; Ulmer WT
    Prax Klin Pneumol; 1980 Dec; 34(12):739-45. PubMed ID: 7465535
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of the internal compliance of a respirator on the alveolar gas distribution.
    Meier A; Baum M
    Acta Anaesthesiol Scand Suppl; 1976; 63():1-20. PubMed ID: 1069456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The construction of a model of the lung for the functional analysis of respirators].
    Llorens J; Belda FJ; Company R; Sarrión J; Barberà M; Chulià V
    Rev Esp Anestesiol Reanim; 1987; 34(3):187-91. PubMed ID: 3475741
    [No Abstract]   [Full Text] [Related]  

  • 18. [Measuring accuracy of commercial respiratory function equipment and ventilation monitors for newborn infants].
    Hauschild M; Schmalisch G; Wauer RR
    Klin Padiatr; 1994; 206(3):167-74. PubMed ID: 8051910
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Advantages of infant ventilators over adapted adult ventilators in pediatrics.
    Binda RE; Cook DR; Fischer CG
    Anesth Analg; 1976; 55(6):769-72. PubMed ID: 1069488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Megamed 0.5.2.2D--a ventilation analyser (author's transl)].
    Schlimgen R; Gürtler F
    Prakt Anaesth; 1978 Feb; 13(1):63-6. PubMed ID: 273210
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.