These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 2679337)

  • 1. The specificity of a rapid method of assay for the presence of Legionella species in water.
    Lim EW; Meers PD
    Ann Acad Med Singap; 1989 Jul; 18(4):348-51. PubMed ID: 2679337
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Legionella species, serogroups and subgroups found in the environment in Singapore.
    Meers PD; Goh KT; Lim EW
    Ann Acad Med Singap; 1989 Jul; 18(4):375-8. PubMed ID: 2802506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of Duopath Legionella lateral flow assay against the conventional culture method using Legionella pneumophila and Legionella anisa strains.
    Koide M; Haranaga S; Higa F; Tateyama M; Yamane N; Fujita J
    Jpn J Infect Dis; 2007 Jul; 60(4):214-6. PubMed ID: 17642537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of detection methods for Legionella species in environmental water by colony isolation, fluorescent antibody staining, and polymerase chain reaction.
    Yamamoto H; Hashimoto Y; Ezaki T
    Microbiol Immunol; 1993; 37(8):617-22. PubMed ID: 8246824
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Legionella species isolated from cooling towers in Kuala Lumpur.
    Ngeow YF; Tan CH; Lim SY
    Med J Malaysia; 1992 Mar; 47(1):15-9. PubMed ID: 1387443
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Legionella pneumophila: monoclonal antibody typing of clinical and environmental isolates.
    Brindle RJ; Stannett PJ; Tobin JO
    Epidemiol Infect; 1987 Oct; 99(2):235-9. PubMed ID: 3678387
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid detection and identification of Legionella pneumophila by a membrane immunoassay.
    Bérubé A; Trudel M; Payment P
    Appl Environ Microbiol; 1989 Jun; 55(6):1640-1. PubMed ID: 2764570
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of the Legipid bioalarm Legionella assay.
    Rodríguez Albalat G; Bedrina Broch B; Jiménez Bono M
    J AOAC Int; 2012; 95(5):1440-51. PubMed ID: 23175978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Isolation of Legionella pneumophila from hospital cooling towers.
    Nadarajah M; Goh KT
    Ann Acad Med Singap; 1986 Jan; 15(1):6-8. PubMed ID: 3707035
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ecological studies of Legionella species. I. Viable counts of Legionella pneumophila in cooling tower water.
    Ikedo M; Yabuuchi E
    Microbiol Immunol; 1986; 30(5):413-23. PubMed ID: 3528766
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inter-laboratory validation of a rapid assay for the detection and quantification of Legionella spp. in water samples.
    Bargellini A; Marchesi I; Leoni E; Mansi A; Cristino S; Marcelloni AM; Borella P
    Lett Appl Microbiol; 2010 Oct; 51(4):421-7. PubMed ID: 20796212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid detection of Legionella pneumophila in water samples.
    Blanco S; Prat C; Sánchez MD; Ferrer D; Pellicer T; Haba L; Latorre I; Vilaplana C; Ausina V; Domínguez J
    Int J Hyg Environ Health; 2008 Mar; 211(1-2):168-71. PubMed ID: 17392021
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Method modification of the Legipid® Legionella fast detection test kit.
    Albalat GR; Broch BB; Bono MJ
    J AOAC Int; 2014; 97(5):1403-9. PubMed ID: 25902991
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Serologic characteristic of Legionella pneumophila strains isolated from potentially dangerous water systems in Russian Federation in 2007 - 2011].
    Dronina IuG; Tartakovskiĭ IS; Sadretdinova OV; Karpova TI; Novokshonova IV; Gruzdeva OA; Karazhas NV; Rybalkina TN
    Zh Mikrobiol Epidemiol Immunobiol; 2012; (2):23-8. PubMed ID: 22693806
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring Legionella species in hospital water systems. Link with disease and evaluation of different detection methods.
    Koziol-Montewka M; Magrys A; Stojek N; Palusinska-Szysz M; Danielak M; Wojtowicz M; Niewiedziol J; Koncewicz R; Niedzwiadek J; Paluch-Oles J; Trzeciak H; Drozanski W; Dutkiewicz J
    Ann Agric Environ Med; 2008; 15(1):143-7. PubMed ID: 18581993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Antiserum-agar plate method for simultaneous detection and direct isolation of Legionella species in clinical and environmental specimens.
    Janssen WA; Hedlund KW
    J Clin Microbiol; 1982 Jun; 15(6):1176-7. PubMed ID: 7050153
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of Legionella pneumophila in environmental water samples using a fluorescein conjugated monoclonal antibody.
    Makin T; Hart CA
    Epidemiol Infect; 1989 Aug; 103(1):105-12. PubMed ID: 2673821
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The relationship between the serogroup antigen and lipopolysaccharide of Legionella pneumophila.
    Conlan JW; Ashworth LA
    J Hyg (Lond); 1986 Feb; 96(1):39-48. PubMed ID: 3950395
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid identification of legionellae by a colony blot assay based on a genus-specific monoclonal antibody.
    Steinmetz I; Rheinheimer C; Bitter-Suermann D
    J Clin Microbiol; 1992 Apr; 30(4):1016-8. PubMed ID: 1374073
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Legionella pneumophila serogroup 9: a cause of human pneumonia.
    Edelstein PH; Bibb WF; Gorman GW; Thacker WL; Brenner DJ; Wilkinson HW; Moss CW; Buddington RS; Dunn CJ; Roos PJ
    Ann Intern Med; 1984 Aug; 101(2):196-8. PubMed ID: 6378003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.