These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
569 related articles for article (PubMed ID: 26794254)
1. Multicenter Evaluation of a 0-Hour/1-Hour Algorithm in the Diagnosis of Myocardial Infarction With High-Sensitivity Cardiac Troponin T. Mueller C; Giannitsis E; Christ M; Ordóñez-Llanos J; deFilippi C; McCord J; Body R; Panteghini M; Jernberg T; Plebani M; Verschuren F; French J; Christenson R; Weiser S; Bendig G; Dilba P; Lindahl B; Ann Emerg Med; 2016 Jul; 68(1):76-87.e4. PubMed ID: 26794254 [TBL] [Abstract][Full Text] [Related]
3. Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Reichlin T; Cullen L; Parsonage WA; Greenslade J; Twerenbold R; Moehring B; Wildi K; Mueller S; Zellweger C; Mosimann T; Rubini Gimenez M; Rentsch K; Osswald S; Müller C Am J Med; 2015 Apr; 128(4):369-79.e4. PubMed ID: 25446294 [TBL] [Abstract][Full Text] [Related]
4. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Reichlin T; Schindler C; Drexler B; Twerenbold R; Reiter M; Zellweger C; Moehring B; Ziller R; Hoeller R; Rubini Gimenez M; Haaf P; Potocki M; Wildi K; Balmelli C; Freese M; Stelzig C; Freidank H; Osswald S; Mueller C Arch Intern Med; 2012 Sep; 172(16):1211-8. PubMed ID: 22892889 [TBL] [Abstract][Full Text] [Related]
5. Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. van der Linden N; Wildi K; Twerenbold R; Pickering JW; Than M; Cullen L; Greenslade J; Parsonage W; Nestelberger T; Boeddinghaus J; Badertscher P; Rubini Giménez M; Klinkenberg LJJ; Bekers O; Schöni A; Keller DI; Sabti Z; Puelacher C; Cupa J; Schumacher L; Kozhuharov N; Grimm K; Shrestha S; Flores D; Freese M; Stelzig C; Strebel I; Miró Ò; Rentsch K; Morawiec B; Kawecki D; Kloos W; Lohrmann J; Richards AM; Troughton R; Pemberton C; Osswald S; van Dieijen-Visser MP; Mingels AM; Reichlin T; Meex SJR; Mueller C Circulation; 2018 Sep; 138(10):989-999. PubMed ID: 29691270 [TBL] [Abstract][Full Text] [Related]
6. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Rubini Gimenez M; Twerenbold R; Jaeger C; Schindler C; Puelacher C; Wildi K; Reichlin T; Haaf P; Merk S; Honegger U; Wagener M; Druey S; Schumacher C; Krivoshei L; Hillinger P; Herrmann T; Campodarve I; Rentsch K; Bassetti S; Osswald S; Mueller C Am J Med; 2015 Aug; 128(8):861-870.e4. PubMed ID: 25840034 [TBL] [Abstract][Full Text] [Related]
7. Clinical impact of the 2010-2012 low-end shift of high-sensitivity cardiac troponin T. Wildi K; Twerenbold R; Jaeger C; Rubini Giménez M; Reichlin T; Stoll M; Hillinger P; Puelacher C; Boeddinghaus J; Nestelberger T; Grimm K; Grob M; Rentsch K; Arnold C; Mueller C Eur Heart J Acute Cardiovasc Care; 2016 Oct; 5(6):399-408. PubMed ID: 27055466 [TBL] [Abstract][Full Text] [Related]
8. A 3-hour diagnostic algorithm for non-ST-elevation myocardial infarction using high-sensitivity cardiac troponin T in unselected older patients presenting to the emergency department. Bahrmann P; Christ M; Bahrmann A; Rittger H; Heppner HJ; Achenbach S; Bertsch T; Sieber CC J Am Med Dir Assoc; 2013 Jun; 14(6):409-16. PubMed ID: 23375478 [TBL] [Abstract][Full Text] [Related]
9. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. Reichlin T; Twerenbold R; Wildi K; Gimenez MR; Bergsma N; Haaf P; Druey S; Puelacher C; Moehring B; Freese M; Stelzig C; Krivoshei L; Hillinger P; Jäger C; Herrmann T; Kreutzinger P; Radosavac M; Weidmann ZM; Pershyna K; Honegger U; Wagener M; Vuillomenet T; Campodarve I; Bingisser R; Miró Ò; Rentsch K; Bassetti S; Osswald S; Mueller C CMAJ; 2015 May; 187(8):E243-E252. PubMed ID: 25869867 [TBL] [Abstract][Full Text] [Related]
10. Use of historical high-sensitivity cardiac troponin T levels to rule out myocardial infarction. Roos A; Holzmann MJ Open Heart; 2021 May; 8(1):. PubMed ID: 33990434 [TBL] [Abstract][Full Text] [Related]
11. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Jaeger C; Wildi K; Twerenbold R; Reichlin T; Rubini Gimenez M; Neuhaus JD; Grimm K; Boeddinghaus J; Hillinger P; Nestelberger T; Singeisen H; Gugala M; Pretre G; Puelacher C; Wagener M; Honegger U; Schumacher C; Moreno Weidmann Z; Kreutzinger P; Krivoshei L; Freese M; Stelzig C; Dietsche S; Ernst S; Rentsch K; Osswald S; Mueller C Am Heart J; 2016 Jan; 171(1):92-102.e1-5. PubMed ID: 26699605 [TBL] [Abstract][Full Text] [Related]
12. Clinical Evaluation of a New High-Sensitivity Cardiac Troponin I Assay for Diagnosis and Risk Assessment of Patients with Suspected Acute Myocardial Infarction. Shiozaki M; Inoue K; Suwa S; Lee CC; Chiang SJ; Sato A; Fukuda K; Kubota N; Tamura H; Fujiwara Y; Yamaguchi K; Sato T; Sumiyoshi M; Daida H Cardiology; 2021; 146(2):172-178. PubMed ID: 33461202 [TBL] [Abstract][Full Text] [Related]
13. A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible Acute Coronary Syndrome in the Emergency Department With High-Sensitivity Troponin T Study (RAPID-TnT). Chew DP; Lambrakis K; Blyth A; Seshadri A; Edmonds MJR; Briffa T; Cullen LA; Quinn S; Karnon J; Chuang A; Nelson AJ; Wright D; Horsfall M; Morton E; French JK; Papendick C Circulation; 2019 Nov; 140(19):1543-1556. PubMed ID: 31478763 [TBL] [Abstract][Full Text] [Related]