These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 26797346)

  • 21. High ventricular lead impedance of a DDD pacemaker after cranial magnetic resonance imaging.
    Baser K; Guray U; Durukan M; Demirkan B
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e251-3. PubMed ID: 21303387
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pacemaker complication during magnetic resonance imaging.
    Rozner MA; Burton AW; Kumar A
    J Am Coll Cardiol; 2005 Jan; 45(1):161-2; author reply 162. PubMed ID: 15629394
    [No Abstract]   [Full Text] [Related]  

  • 23. Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker.
    Gimbel JR
    Europace; 2009 Sep; 11(9):1241-2. PubMed ID: 19556252
    [TBL] [Abstract][Full Text] [Related]  

  • 24. First MRI-safe pacemaker receives conditional approval from FDA.
    Mitka M
    JAMA; 2011 Mar; 305(10):985-6. PubMed ID: 21386073
    [No Abstract]   [Full Text] [Related]  

  • 25. Magnetic resonance imaging for patients with permanent pacemakers: initial clinical experience.
    Goldsher D; Amikam S; Boulos M; Suleiman M; Shreiber R; Eran A; Goldshmid Y; Mazbar R; Roguin A
    Isr Med Assoc J; 2006 Feb; 8(2):91-4. PubMed ID: 16544729
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Heating of pacemaker leads during magnetic resonance imaging.
    Vahlhaus C
    Eur Heart J; 2005 Jun; 26(12):1243; author reply 1243-4. PubMed ID: 15872035
    [No Abstract]   [Full Text] [Related]  

  • 27. [A patient with an event recorder in MRI].
    Nitschke T; Schürmann K; Heuer H
    Rofo; 2010 Nov; 182(11):1011-3. PubMed ID: 20922649
    [No Abstract]   [Full Text] [Related]  

  • 28. Diagnosis and treatment of an intramedullary cavernoma in a young male with an implanted cardiac pacemaker.
    Fritzsche E; Flitsch J; Kucinski T; Lund GK; Papavero L; Westphal M
    Acta Neurochir (Wien); 2006 Nov; 148(11):1213-5; discussion 1215. PubMed ID: 17021651
    [No Abstract]   [Full Text] [Related]  

  • 29. [Pacemaker or ICD and MRI: is MRI safety the new standard?].
    Amara W
    Ann Cardiol Angeiol (Paris); 2011 Nov; 60(5):279-81. PubMed ID: 21907320
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Summaries for patients. The safety of magnetic resonance imaging in patients with pacemakers or defibrillators.
    Ann Intern Med; 2011 Oct; 155(7):I34. PubMed ID: 21969352
    [No Abstract]   [Full Text] [Related]  

  • 31. [Safety standards for the use of magnetic resonance in patients with cardiovascular devices].
    Waldman SV; Grancelli H; Yaman B; Cohen Arazi H
    Medicina (B Aires); 2011; 71(1):78-82. PubMed ID: 21296728
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Early MRI scanning of device patients-not so fast.
    Roguin A
    Pacing Clin Electrophysiol; 2013 Dec; 36(12):1447-8. PubMed ID: 23827057
    [No Abstract]   [Full Text] [Related]  

  • 33. Safety and outcomes of magnetic resonance imaging in patients with abandoned pacemaker and defibrillator leads.
    Higgins JV; Gard JJ; Sheldon SH; Espinosa RE; Wood CP; Felmlee JP; Cha YM; Asirvatham SJ; Dalzell C; Acker N; Watson RE; Friedman PA
    Pacing Clin Electrophysiol; 2014 Oct; 37(10):1284-90. PubMed ID: 24809591
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The AHA Scientific Statement of MRI in patients with devices: neat, but incomplete. Unwise and unsupported.
    Gimbel JR
    Pacing Clin Electrophysiol; 2008 Jun; 31(6):649-51. PubMed ID: 18507535
    [No Abstract]   [Full Text] [Related]  

  • 35. Safe, sensible, sagacious: responsible scanning of pacemaker patients.
    Gimbel JR; Wilkoff BL; Kanal E; Rozner MA
    Eur Heart J; 2005 Aug; 26(16):1683-4. PubMed ID: 15946956
    [No Abstract]   [Full Text] [Related]  

  • 36. [Magnetic resonance imaging of patients with cardiac pacemakers--a safe mode of operation].
    Kaasalainen T; Pakarinen S; Hänninen H
    Duodecim; 2015; 131(8):737-43. PubMed ID: 26237889
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reconsideration of pacemakers and MR imaging.
    Loewy J; Loewy A; Kendall EJ
    Radiographics; 2004; 24(5):1257-67; discussion 1267-8. PubMed ID: 15371606
    [TBL] [Abstract][Full Text] [Related]  

  • 38. MR imaging in patients with epicardial pacemaker wires.
    Murphy KJ; Cohan RH; Ellis JH
    AJR Am J Roentgenol; 1999 Mar; 172(3):727-8. PubMed ID: 10063869
    [No Abstract]   [Full Text] [Related]  

  • 39. Magnetic resonance imaging in patients with cardiac pacemakers.
    Sommer T; Naehle CP; Schild H
    J Am Coll Cardiol; 2005 Aug; 46(3):561-2; author reply 562. PubMed ID: 16053976
    [No Abstract]   [Full Text] [Related]  

  • 40. Ask the doctor. Last month you wrote about MRIs being bad for pacemakers and defibrillators. What about stents? They are metal, too. I had two stents put in a few months ago. Can I ever have an MRI?
    Lee T
    Harv Heart Lett; 2006 May; 16(9):8. PubMed ID: 16688883
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.