These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 26810930)

  • 1. A Finite-Element Study of Metal Backing and Tibial Resection Depth in a Composite Tibia Following Total Knee Arthroplasty.
    Tokunaga S; Rogge RD; Small SR; Berend ME; Ritter MA
    J Biomech Eng; 2016 Apr; 138(4):041001. PubMed ID: 26810930
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of tibial component malalignment on bone strain in revision total knee replacement.
    Rastetter BR; Wright SJ; Gheduzzi S; Miles AW; Clift SE
    Proc Inst Mech Eng H; 2016 Jun; 230(6):561-8. PubMed ID: 27006420
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison in proximal tibial strain between metal-backed and all-polyethylene anatomic graduated component total knee arthroplasty tibial components.
    Small SR; Berend ME; Ritter MA; Buckley CA
    J Arthroplasty; 2010 Aug; 25(5):820-5. PubMed ID: 20638615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis.
    Houdek MT; Watts CD; Wyles CC; Martin JR; Trousdale RT; Taunton MJ
    J Arthroplasty; 2017 Mar; 32(3):836-842. PubMed ID: 27816367
    [TBL] [Abstract][Full Text] [Related]  

  • 5. All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.
    Brihault J; Navacchia A; Pianigiani S; Labey L; De Corte R; Pascale V; Innocenti B
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2550-9. PubMed ID: 25957612
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite-Element Analysis of Stress on the Proximal Tibia After Unicompartmental Knee Arthroplasty.
    Sano M; Oshima Y; Murase K; Sasatani K; Takai S
    J Nippon Med Sch; 2020 Dec; 87(5):260-267. PubMed ID: 32009074
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method.
    Apostolopoulos V; Tomáš T; Boháč P; Marcián P; Mahdal M; Valoušek T; Janíček P; Nachtnebl L
    Comput Methods Programs Biomed; 2022 Jun; 220():106834. PubMed ID: 35490458
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stress shielding in periprosthetic bone following a total knee replacement: Effects of implant material, design and alignment.
    Zhang QH; Cossey A; Tong J
    Med Eng Phys; 2016 Dec; 38(12):1481-1488. PubMed ID: 27745873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proximal tibial strain in medial unicompartmental knee replacements: A biomechanical study of implant design.
    Scott CE; Eaton MJ; Nutton RW; Wade FA; Pankaj P; Evans SL
    Bone Joint J; 2013 Oct; 95-B(10):1339-47. PubMed ID: 24078529
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effects of bone resection depth and malalignment on strain in the proximal tibia after total knee arthroplasty.
    Berend ME; Small SR; Ritter MA; Buckley CA
    J Arthroplasty; 2010 Feb; 25(2):314-8. PubMed ID: 19346099
    [TBL] [Abstract][Full Text] [Related]  

  • 11. All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.
    Houdek MT; Wagner ER; Wyles CC; Watts CD; Cass JR; Trousdale RT
    J Arthroplasty; 2016 Jul; 31(7):1476-82. PubMed ID: 27067171
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finite-Element analysis of a lateral femoro-tibial impact on the total knee arthroplasty.
    Arab AZE; Merdji A; Benaissa A; Roy S; Bachir Bouiadjra BA; Layadi K; Ouddane A; Mukdadi OM
    Comput Methods Programs Biomed; 2020 Aug; 192():105446. PubMed ID: 32200048
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Metal backing significantly decreases tibial strains in a medial unicompartmental knee arthroplasty model.
    Small SR; Berend ME; Ritter MA; Buckley CA; Rogge RD
    J Arthroplasty; 2011 Aug; 26(5):777-82. PubMed ID: 20870385
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis.
    Completo A; Rego A; Fonseca F; Ramos A; Relvas C; Simões JA
    Clin Biomech (Bristol, Avon); 2010 Feb; 25(2):159-65. PubMed ID: 19944503
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method.
    Apostolopoulos V; Boháč P; Marcián P; Nachtnebl L; Mahdal M; Pazourek L; Tomáš T
    J Orthop Surg Res; 2024 Feb; 19(1):153. PubMed ID: 38396020
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of femoral component size on proximal tibial strain with anatomic graduated components total knee arthroplasty.
    Berend ME; Small SR; Ritter MA; Buckley CA; Merk JC; Dierking WK
    J Arthroplasty; 2010 Jan; 25(1):58-63. PubMed ID: 19097851
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.
    Shen Y; Li X; Fu X; Wang W
    Knee Surg Sports Traumatol Arthrosc; 2015 Nov; 23(11):3330-6. PubMed ID: 25073943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite Element Analysis of Mobile-bearing Unicompartmental Knee Arthroplasty: The Influence of Tibial Component Coronal Alignment.
    Zhu GD; Guo WS; Zhang QD; Liu ZH; Cheng LM
    Chin Med J (Engl); 2015 Nov; 128(21):2873-8. PubMed ID: 26521784
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of malalignment on proximal tibial strain in fixed-bearing unicompartmental knee arthroplasty: A comparison between metal-backed and all-polyethylene components using a validated finite element model.
    Danese I; Pankaj P; Scott CEH
    Bone Joint Res; 2019 Feb; 8(2):55-64. PubMed ID: 30915211
    [TBL] [Abstract][Full Text] [Related]  

  • 20. All-polyethylene vs. metal-backed tibial component in total knee arthroplasty-a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 1. Horizontally cemented components: AP better fixated than MB.
    Hyldahl H; Regnér L; Carlsson L; Kärrholm J; Weidenhielm L
    Acta Orthop; 2005 Dec; 76(6):769-77. PubMed ID: 16470428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.