BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 26813110)

  • 1. Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.
    Evin M; Guivier-Curien C; Pibarot P; Kadem L; Rieu R
    Artif Organs; 2016 May; 40(5):E52-60. PubMed ID: 26813110
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comprehensive hemodynamic assessment of 368 normal St. Jude Medical mechanical mitral valve prostheses based on early postimplantation echocardiographic studies.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Suri RM; Miller FA
    J Am Soc Echocardiogr; 2013 Apr; 26(4):381-9. PubMed ID: 23484437
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestimation by Doppler.
    Evin M; Pibarot P; Guivier-Curien C; Tanné D; Kadem L; Rieu R
    J Am Soc Echocardiogr; 2013 Jul; 26(7):791-800. PubMed ID: 23611059
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of Effective Orifice Areas of Mitral Prosthetic Heart Valves: An In-Vitro Study.
    Evin M; Magne J; Grieve SM; Rieu R; Pibarot P
    J Heart Valve Dis; 2017 Nov; 26(6):677-687. PubMed ID: 30207118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical].
    Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A
    G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Late results after mitral valve replacement with bileaflet mechanical prosthesis in children: evaluation of prosthesis-patient mismatch.
    Masuda M; Kado H; Tatewaki H; Shiokawa Y; Yasui H
    Ann Thorac Surg; 2004 Mar; 77(3):913-7. PubMed ID: 14992898
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodynamic performance of four mechanical bileaflet prosthetic valves in the mitral position: an echocardiographic study.
    Reisner SA; Harpaz D; Skulski R; Borenstein D; Milo S; Meltzer RS
    Eur J Ultrasound; 1998 Dec; 8(3):193-200. PubMed ID: 9971902
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: an in vivo and in vitro study.
    Bech-Hanssen O; Caidahl K; Wallentin I; Ask P; Wranne B
    J Thorac Cardiovasc Surg; 2001 Aug; 122(2):287-95. PubMed ID: 11479501
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comprehensive hemodynamic assessment of 305 normal CarboMedics mitral valve prostheses based on early postimplantation echocardiographic studies.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Sundt TM; Miller FA
    J Am Soc Echocardiogr; 2012 Feb; 25(2):173-81. PubMed ID: 22133689
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Doppler echocardiography of 119 normal-functioning St Jude Medical mitral valve prostheses: a comprehensive assessment including time-velocity integral ratio and prosthesis performance index.
    Malouf JF; Ballo M; Connolly HM; Hodge DO; Herges RM; Mullany CJ; Miller FA
    J Am Soc Echocardiogr; 2005 Mar; 18(3):252-6. PubMed ID: 15746715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Doppler derived gradient of St. Jude mechanical prosthesis, early postoperative assessment.
    Shaikh AH; Hanif B; Adil A; Hashmani S; Qazi HA; Mujtaba I
    J Pak Med Assoc; 2010 May; 60(5):374-6. PubMed ID: 20527611
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mitral prosthesis malfunction. Comparative Doppler echocardiographic studies of mitral prostheses before and after replacement.
    Nellessen U; Masuyama T; Appleton CP; Tye T; Popp RL
    Circulation; 1989 Feb; 79(2):330-6. PubMed ID: 2914351
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of prosthetic valve malfunction on the Doppler-catheter gradient relation for bileaflet aortic valve prostheses.
    Baumgartner H; Schima H; Kühn P
    Circulation; 1993 Apr; 87(4):1320-7. PubMed ID: 8462155
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multiparametric Approach for the Assessment of Mechanical Prosthetic Tricuspid Leaflet Function.
    Fadel BM; Alassas K; Clavel MA; Ayas MF; Kazzi BE; Pibarot P; Mohty D
    J Am Soc Echocardiogr; 2022 Feb; 35(2):206-216. PubMed ID: 34508836
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients.
    Bach DS; Schmitz C; Dohmen G; Aaronson KD; Steinseifer U; Kleine P
    J Thorac Cardiovasc Surg; 2012 Aug; 144(2):453-8. PubMed ID: 22264413
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-vivo experience with the Triflo trileaflet mechanical heart valve.
    Gallegos RP; Rivard AL; Suwan PT; Black S; Bertog S; Steinseifer U; Armien A; Lahti M; Bianco RW
    J Heart Valve Dis; 2006 Nov; 15(6):791-9. PubMed ID: 17152787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography.
    Cianciulli TE; Lax JA; Beck MA; Cerruti FE; Gigena GE; Saccheri MC; Fernández E; Dorelle AN; Leguizamón JH; Prezioso HA
    J Heart Valve Dis; 2005 Sep; 14(5):664-73. PubMed ID: 16245506
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy.
    Muratori M; Montorsi P; Maffessanti F; Teruzzi G; Zoghbi WA; Gripari P; Tamborini G; Ghulam Ali S; Fusini L; Fiorentini C; Pepi M
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):196-205. PubMed ID: 23489533
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
    Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E
    G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
    Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.