These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 26815473)

  • 1. Long-term follow-up of blowout fractures of the orbital floor reconstructed with a polyglactin 910/PDS implant.
    Blake F; Blessmann M; Smeets R; Friedrich R; Schmelzle R; Heiland M; Eichhorn W
    Eur J Trauma Emerg Surg; 2011 Dec; 37(6):609-13. PubMed ID: 26815473
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (ethisorb): a retrospective study.
    Büchel P; Rahal A; Seto I; Iizuka T
    J Oral Maxillofac Surg; 2005 May; 63(5):646-50. PubMed ID: 15883939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Orbital floor fractures--short- and intermediate-term complications depending on treatment procedures.
    Holtmann H; Eren H; Sander K; Kübler NR; Handschel J
    Head Face Med; 2016 Jan; 12():1. PubMed ID: 26729217
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Orbital floor reconstruction with flexible Ethisorb patches: a retrospective long-term follow-up study.
    Jank S; Emshoff R; Schuchter B; Strobl H; Brandlmaier I; Norer B
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jan; 95(1):16-22. PubMed ID: 12539022
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical Outcome Following Surgical Repair of Small Versus Large Orbital Floor Fractures Using Polyglactin 910/Polydioxanone (Ethisorb
    Steinmassl O; Laimer J; Offermanns V; Wildauer M; Steinmassl PA; Grams AE; Kofler F; Rasse M; Bruckmoser E
    Materials (Basel); 2020 Jan; 13(1):. PubMed ID: 31947782
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction of orbital floor fracture using solvent-preserved bone graft.
    Yavuzer R; Tuncer S; Başterzi Y; Işik I; Sari A; Latifoğlu O
    Plast Reconstr Surg; 2004 Jan; 113(1):34-44. PubMed ID: 14707620
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combined use of titanium mesh and resorbable PLLA-PGA implant in the treatment of large orbital floor fractures.
    Magaña FG; Arzac RM; De Hilario Avilés L
    J Craniofac Surg; 2011 Nov; 22(6):1991-5. PubMed ID: 22067850
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repair of orbital floor fractures with bioactive glass implants.
    Aitasalo K; Kinnunen I; Palmgren J; Varpula M
    J Oral Maxillofac Surg; 2001 Dec; 59(12):1390-5; discussion 1395-6. PubMed ID: 11732018
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Medpor porous polyethylene implants in orbital blowout fracture repair.
    Ng SG; Madill SA; Inkster CF; Maloof AJ; Leatherbarrow B
    Eye (Lond); 2001 Oct; 15(Pt 5):578-82. PubMed ID: 11702965
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic intranasal reduction of the orbit in isolated blowout fractures.
    Jeon SY; Kwon JH; Kim JP; Ahn SK; Park JJ; Hur DG; Seo SW
    Acta Otolaryngol Suppl; 2007 Oct; (558):102-9. PubMed ID: 17882579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Role of Resorbable Plate and Artificial Bone Substitute in Reconstruction of Large Orbital Floor Defect.
    Kwon H; Kim HJ; Seo BF; Jeong YJ; Jung SN; Shim HS
    Biomed Res Int; 2016; 2016():1358312. PubMed ID: 27517041
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of polydioxanone (PDS) foil thickness on reconstruction of the orbital geometry after isolated orbital floor fractures.
    Winnand P; Ooms M; Ayoub N; Schick D; Paulßen von Beck F; Hölzle F; Mücke T; Modabber A
    Eur J Trauma Emerg Surg; 2024 Jun; ():. PubMed ID: 38940951
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prospective Evaluation of Two Wall Orbital Fractures Involving the Medial Orbital Wall: PSI Reconstruction versus PDS Repair-Worth the Effort?
    Wilkat M; Hufendiek K; Karahisarlioglu M; Borrelli M; Sproll C; Rana M
    J Pers Med; 2022 Aug; 12(9):. PubMed ID: 36143174
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Combined transcutaneous transethmoidal/transorbital approach for the treatment of medial orbital blowout fractures.
    Kim KS; Kim ES; Hwang JH
    Plast Reconstr Surg; 2006 May; 117(6):1947-55. PubMed ID: 16651969
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Orbital floor fractures: evaluation, indications, approach, and pearls from an ophthalmologist's perspective.
    Lelli GJ; Milite J; Maher E
    Facial Plast Surg; 2007 Aug; 23(3):190-9. PubMed ID: 17691067
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Repair of orbital floor fractures: our experience and new technical findings.
    Piombino P; Iaconetta G; Ciccarelli R; Romeo A; Spinzia A; Califano L
    Craniomaxillofac Trauma Reconstr; 2010 Dec; 3(4):217-22. PubMed ID: 22132260
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Endoscope-assisted repair of pediatric blowout fractures of orbital floor with autologous bone fragment].
    Jiang XL; Miao HP; Zhou ZY; Zhang XR; Liu JL
    Zhonghua Yi Xue Za Zhi; 2013 Sep; 93(33):2664-6. PubMed ID: 24360049
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical management of persistent diplopia in blowout fractures of the orbit.
    Harley RD
    Ann Ophthalmol; 1975 Dec; 7(12):1621-6. PubMed ID: 1225104
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A New Option for the Reconstruction of Orbital Floor Defects: The Olecranon Bone Graft.
    Yeşiloğlu N; Şirinoğlu H; Sarici M; Temiz G; Filinte GT
    Ann Plast Surg; 2015 Oct; 75(4):401-6. PubMed ID: 24691341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Repair of orbital floor fractures via the transantral approach with osteosynthesis plate.
    Pankratov AS; Gotsiridze ZP; Kondrat AN; Karalkin AV
    Oral Maxillofac Surg; 2020 Sep; 24(3):309-316. PubMed ID: 32415412
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.