These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 26818696)
1. A titanium nitride nanotube array for potentiometric sensing of pH. Liu M; Ma Y; Su L; Chou KC; Hou X Analyst; 2016 Mar; 141(5):1693-9. PubMed ID: 26818696 [TBL] [Abstract][Full Text] [Related]
2. Titanium Nitride Thin Film Based Low-Redox-Interference Potentiometric pH Sensing Electrodes. Paul Shylendra S; Lonsdale W; Wajrak M; Nur-E-Alam M; Alameh K Sensors (Basel); 2020 Dec; 21(1):. PubMed ID: 33374837 [TBL] [Abstract][Full Text] [Related]
3. Coaxial Ni(x)Co(2x)(OH)(6x)/TiN nanotube arrays as supercapacitor electrodes. Shang C; Dong S; Wang S; Xiao D; Han P; Wang X; Gu L; Cui G ACS Nano; 2013 Jun; 7(6):5430-6. PubMed ID: 23647174 [TBL] [Abstract][Full Text] [Related]
4. Ultrahigh electrocatalytic activity with trace amounts of platinum loadings on free-standing mesoporous titanium nitride nanotube arrays for hydrogen evolution reactions. Zhao J; Zeng Y; Wang J; Xu Q; Chen R; Ni H; Cheng GJ Nanoscale; 2020 Jul; 12(28):15393-15401. PubMed ID: 32656553 [TBL] [Abstract][Full Text] [Related]
5. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative. Kormalı Ertürün HE; Demirel Özel A; Sayın S; Yılmaz M; Kılıç E Talanta; 2015 Jan; 132():669-75. PubMed ID: 25476362 [TBL] [Abstract][Full Text] [Related]
6. All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. Yuan D; Anthis AH; Ghahraman Afshar M; Pankratova N; Cuartero M; Crespo GA; Bakker E Anal Chem; 2015 Sep; 87(17):8640-5. PubMed ID: 26272001 [TBL] [Abstract][Full Text] [Related]
7. Ruthenium Oxide Nanorods as Potentiometric pH Sensor for Organs-On-Chip Purposes. Tanumihardja E; Olthuis W; van den Berg A Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30200489 [TBL] [Abstract][Full Text] [Related]
8. Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene for detection of Sn(II) in real samples. Arvand M; Moghimi AM; Afshari A; Mahmoodi N Anal Chim Acta; 2006 Oct; 579(1):102-8. PubMed ID: 17723734 [TBL] [Abstract][Full Text] [Related]
9. A single-walled carbon nanotube thin film-based pH-sensing microfluidic chip. Li CA; Han KN; Pham XH; Seong GH Analyst; 2014 Apr; 139(8):2011-5. PubMed ID: 24611156 [TBL] [Abstract][Full Text] [Related]
10. Flow injection analysis of sulfite ion with a potentiometric titanium phosphate-epoxy based membrane sensor. Hassan SS; Marei SA; Badr IH; Arida HA Talanta; 2001 May; 54(4):773-82. PubMed ID: 18968300 [TBL] [Abstract][Full Text] [Related]
11. Ion-selective electrode for the determination of prenalterol. Khalil S; El-Ries MA Talanta; 2003 May; 59(6):1259-66. PubMed ID: 18969017 [TBL] [Abstract][Full Text] [Related]
12. The Development of CMOS Amperometric Sensing Chip with a Novel 3-Dimensional TiN Nano-Electrode Array. Lien CL; Yuan CJ Sensors (Basel); 2019 Feb; 19(5):. PubMed ID: 30813577 [TBL] [Abstract][Full Text] [Related]
13. Fabrication and Optimization of Nafion as a Protective Membrane for TiN-Based pH Sensors. Paul Shylendra S; Wajrak M; Alameh K Sensors (Basel); 2023 Feb; 23(4):. PubMed ID: 36850929 [TBL] [Abstract][Full Text] [Related]
14. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples. Gupta VK; Singh AK; Gupta B Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212 [TBL] [Abstract][Full Text] [Related]
15. Potentiometric RuO2-Ta2O5 pH sensors fabricated using thick film and LTCC technologies. Manjakkal L; Zaraska K; Cvejin K; Kulawik J; Szwagierczak D Talanta; 2016 Jan; 147():233-40. PubMed ID: 26592601 [TBL] [Abstract][Full Text] [Related]
16. Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor. Ganjali MR; Norouzi P; Alizadeh T; Adib M Anal Chim Acta; 2006 Aug; 576(2):275-82. PubMed ID: 17723643 [TBL] [Abstract][Full Text] [Related]
17. Bulk Ti nitride prepared from rutile TiO Canillas M; Moreno B; Carballo-Vila M; Jurado JR; Chinarro E Mater Sci Eng C Mater Biol Appl; 2019 Mar; 96():295-301. PubMed ID: 30606535 [TBL] [Abstract][Full Text] [Related]
18. Stoichiometry, Length, and Wall Thickness Optimization of TiO2 Nanotube Array for Efficient Alcohol Sensing. Hazra A; Bhowmik B; Dutta K; Chattopadhyay PP; Bhattacharyya P ACS Appl Mater Interfaces; 2015 May; 7(18):9336-48. PubMed ID: 25918822 [TBL] [Abstract][Full Text] [Related]
19. Fabrication and Characterization of a Ruthenium Nitride Membrane for Electrochemical pH Sensors. Liao YH; Chou JC Sensors (Basel); 2009; 9(4):2478-90. PubMed ID: 22574026 [TBL] [Abstract][Full Text] [Related]