These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 26818820)

  • 21. Magnetoacoustic tomography with magnetic induction (MAT-MI) for electrical conductivity imaging.
    Li X; He B
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3173-6. PubMed ID: 19964795
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction.
    Ma Q; He B
    Phys Med Biol; 2007 Aug; 52(16):5085-99. PubMed ID: 17671355
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Magneto-Acousto-Electrical Tomography With Magnetic Induction for Conductivity Reconstruction.
    Guo L; Liu G; Xia H
    IEEE Trans Biomed Eng; 2015 Sep; 62(9):2114-24. PubMed ID: 25532166
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The experimental study of mouse liver in magneto-acousto-electrical tomography by scan mode.
    Li Y; Song J; Xia H; Liu G
    Phys Med Biol; 2020 Nov; 65(21):215024. PubMed ID: 33151907
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Implementation method for magneto-acoustic concentration tomography with magnetic induction (MACT-MI) based on the method of moments.
    Yan X; Xu Z; Chen W; Pan Y
    Comput Biol Med; 2021 Jan; 128():104105. PubMed ID: 33220591
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Numerical implementation of magneto-acousto-electrical tomography (MAET) using a linear phased array transducer.
    Gözü MS; Zengin R; Gençer NG
    Phys Med Biol; 2018 Jan; 63(3):035012. PubMed ID: 29372692
    [TBL] [Abstract][Full Text] [Related]  

  • 27. M-sequence-coded excitation for magneto-acoustic imaging.
    Zhang S; Ma R; Yin T; Liu Z
    Med Biol Eng Comput; 2019 May; 57(5):1059-1067. PubMed ID: 30569398
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Magneto-acoustic imaging by continuous-wave excitation.
    Shunqi Z; Zhou X; Tao Y; Zhipeng L
    Med Biol Eng Comput; 2017 Apr; 55(4):595-607. PubMed ID: 27370787
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Lorentz force electrical impedance tomography using magnetic field measurements.
    Zengin R; Gençer NG
    Phys Med Biol; 2016 Aug; 61(16):5887-905. PubMed ID: 27436483
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The influence on acoustic frequency characteristics of conductivity gradual-varying tissue in magnetoacoustic tomography (MAT).
    Zhao X; Liu G; Yan X; Chen X; Chen S
    Comput Biol Med; 2019 Jan; 104():105-110. PubMed ID: 30468913
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of the secondary process on mass point vibration velocity propagation in magneto-acoustic tomography and magneto-acousto-electrical tomography.
    Sun Z; Liu G; Guo L; Xia H; Wang X
    Technol Health Care; 2016 Apr; 24 Suppl 2():S683-9. PubMed ID: 27177099
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Magneto-acousto-electrical Measurement Based Electrical Conductivity Reconstruction for Tissues.
    Zhou Y; Ma Q; Guo G; Tu J; Zhang D
    IEEE Trans Biomed Eng; 2018 May; 65(5):1086-1094. PubMed ID: 28829300
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ramp-preserving denoising for conductivity image reconstruction in magnetic resonance electrical impedance tomography.
    Lee CO; Jeon K; Ahn S; Kim HJ; Woo EJ
    IEEE Trans Biomed Eng; 2011 Jul; 58(7):2038-50. PubMed ID: 21693387
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimization of multi-angle Magneto-Acousto-Electrical Tomography (MAET) based on a numerical method.
    Sun T; Zeng X; Hao PH; Chin CT; Chen M; Yan JJ; Dai M; Lin HM; Chen S; Chen X
    Math Biosci Eng; 2020 Mar; 17(4):2864-2880. PubMed ID: 32987504
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm.
    Kwon O; Woo EJ; Yoon JR; Seo JK
    IEEE Trans Biomed Eng; 2002 Feb; 49(2):160-7. PubMed ID: 12066883
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimization of measurement arrangements for magnetic detection electrical impedance tomography.
    Hao L; Li G; Lin L
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):444-52. PubMed ID: 24013827
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A study on locating the sonic source of sinusoidal magneto-acoustic signals using a vector method.
    Zhang S; Zhou X; Ma R; Yin T; Liu Z
    Biomed Mater Eng; 2015; 26 Suppl 1():S1177-84. PubMed ID: 26405875
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A reconstruction algorithm of magnetoacoustic tomography with magnetic induction for an acoustically inhomogeneous tissue.
    Zhou L; Zhu S; He B
    IEEE Trans Biomed Eng; 2014 Jun; 61(6):1739-46. PubMed ID: 24845284
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Acoustic Source Analysis of Magnetoacoustic Tomography With Magnetic Induction for Conductivity Gradual-Varying Tissues.
    Wang J; Zhou Y; Sun X; Ma Q; Zhang D
    IEEE Trans Biomed Eng; 2016 Apr; 63(4):758-64. PubMed ID: 26292332
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Research on Time-frequency Characteristics of Magneto-acoustic Signal of Different Thickness Medium Based on Wave Summing Method].
    Zhang S; Yin T; Ma R; Liu Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2015 Aug; 32(4):717-24. PubMed ID: 26710438
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.