465 related articles for article (PubMed ID: 26823746)
1. Low tidal volume with PEEP and recruitment expedite the recovery of pulmonary function.
Pi X; Cui Y; Wang C; Guo L; Sun B; Shi J; Lin Z; Zhao N; Wang W; Fu S; Li E
Int J Clin Exp Pathol; 2015; 8(11):14305-14. PubMed ID: 26823746
[TBL] [Abstract][Full Text] [Related]
2. Ventilation with high versus low peep levels during general anaesthesia for open abdominal surgery does not affect postoperative spirometry: A randomised clinical trial.
Treschan TA; Schaefer M; Kemper J; Bastin B; Kienbaum P; Pannen B; Hemmes SN; de Abreu MG; Pelosi P; Schultz MJ;
Eur J Anaesthesiol; 2017 Aug; 34(8):534-543. PubMed ID: 28306591
[TBL] [Abstract][Full Text] [Related]
3. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicentre randomised controlled trial.
; Hemmes SN; Gama de Abreu M; Pelosi P; Schultz MJ
Lancet; 2014 Aug; 384(9942):495-503. PubMed ID: 24894577
[TBL] [Abstract][Full Text] [Related]
4. Individual Positive End-expiratory Pressure Settings Optimize Intraoperative Mechanical Ventilation and Reduce Postoperative Atelectasis.
Pereira SM; Tucci MR; Morais CCA; Simões CM; Tonelotto BFF; Pompeo MS; Kay FU; Pelosi P; Vieira JE; Amato MBP
Anesthesiology; 2018 Dec; 129(6):1070-1081. PubMed ID: 30260897
[TBL] [Abstract][Full Text] [Related]
5. Effect of Intraoperative High Positive End-Expiratory Pressure (PEEP) With Recruitment Maneuvers vs Low PEEP on Postoperative Pulmonary Complications in Obese Patients: A Randomized Clinical Trial.
; Bluth T; Serpa Neto A; Schultz MJ; Pelosi P; Gama de Abreu M; ; Bluth T; Bobek I; Canet JC; Cinnella G; de Baerdemaeker L; Gama de Abreu M; Gregoretti C; Hedenstierna G; Hemmes SNT; Hiesmayr M; Hollmann MW; Jaber S; Laffey J; Licker MJ; Markstaller K; Matot I; Mills GH; Mulier JP; Pelosi P; Putensen C; Rossaint R; Schmitt J; Schultz MJ; Senturk M; Serpa Neto A; Severgnini P; Sprung J; Vidal Melo MF; Wrigge H
JAMA; 2019 Jun; 321(23):2292-2305. PubMed ID: 31157366
[TBL] [Abstract][Full Text] [Related]
6. Lung-protective mechanical ventilation for patients undergoing abdominal laparoscopic surgeries: a randomized controlled trial.
Nguyen TK; Nguyen VL; Nguyen TG; Mai DH; Nguyen NQ; Vu TA; Le AN; Nguyen QH; Nguyen CT; Nguyen DT
BMC Anesthesiol; 2021 Mar; 21(1):95. PubMed ID: 33784987
[TBL] [Abstract][Full Text] [Related]
7. Low Tidal Volume Positive End-Expiratory Pressure versus High Tidal Volume Zero-Positive End-Expiratory Pressure and Postoperative Pulmonary Functions in Robot-Assisted Laparoscopic Radical Prostatectomy.
Haliloglu M; Bilgili B; Ozdemir M; Umuroglu T; Bakan N
Med Princ Pract; 2017; 26(6):573-578. PubMed ID: 29131002
[TBL] [Abstract][Full Text] [Related]
8. Driving Pressure During General Anesthesia for Open Abdominal Surgery (DESIGNATION): study protocol of a randomized clinical trial.
DESIGNATION–investigators
Trials; 2020 Feb; 21(1):198. PubMed ID: 32070400
[TBL] [Abstract][Full Text] [Related]
9. Lung-protective ventilation in abdominal surgery.
Futier E; Jaber S
Curr Opin Crit Care; 2014 Aug; 20(4):426-30. PubMed ID: 24927044
[TBL] [Abstract][Full Text] [Related]
10. Ventilation With High or Low Tidal Volume With PEEP Does Not Influence Lung Function After Spinal Surgery in Prone Position: A Randomized Controlled Trial.
Soh S; Shim JK; Ha Y; Kim YS; Lee H; Kwak YL
J Neurosurg Anesthesiol; 2018 Jul; 30(3):237-245. PubMed ID: 28338504
[TBL] [Abstract][Full Text] [Related]
11. Recruitment of lung volume during surgery neither affects the postoperative spirometry nor the risk of hypoxaemia after laparoscopic gastric bypass in morbidly obese patients: a randomized controlled study.
Defresne AA; Hans GA; Goffin PJ; Bindelle SP; Amabili PJ; DeRoover AM; Poirrier R; Brichant JF; Joris JL
Br J Anaesth; 2014 Sep; 113(3):501-7. PubMed ID: 24833726
[TBL] [Abstract][Full Text] [Related]
12. Effects of different ventilation strategies on exhaled nitric oxide in geriatric abdominal surgery.
Cui Y; Pi X; Wang C; Liu S; Gong Y; Wang Y; Zhang F; Shi J; Lin Z; Zhang X; Li E
J Breath Res; 2015 Feb; 9(1):016006. PubMed ID: 25719610
[TBL] [Abstract][Full Text] [Related]
13. Effects of intraoperative individualized PEEP on postoperative atelectasis in obese patients: study protocol for a prospective randomized controlled trial.
Zhu C; Yao JW; An LX; Bai YF; Li WJ
Trials; 2020 Jul; 21(1):618. PubMed ID: 32631414
[TBL] [Abstract][Full Text] [Related]
14. Protective mechanical ventilation during general anesthesia for open abdominal surgery improves postoperative pulmonary function.
Severgnini P; Selmo G; Lanza C; Chiesa A; Frigerio A; Bacuzzi A; Dionigi G; Novario R; Gregoretti C; de Abreu MG; Schultz MJ; Jaber S; Futier E; Chiaranda M; Pelosi P
Anesthesiology; 2013 Jun; 118(6):1307-21. PubMed ID: 23542800
[TBL] [Abstract][Full Text] [Related]
15. Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile.
Wirth S; Baur M; Spaeth J; Guttmann J; Schumann S
Br J Anaesth; 2015 Mar; 114(3):483-90. PubMed ID: 25416274
[TBL] [Abstract][Full Text] [Related]
16. Effects of intraoperative PEEP optimization on postoperative pulmonary complications and the inflammatory response: study protocol for a randomized controlled trial.
Ruszkai Z; Kiss E; László I; Gyura F; Surány E; Bartha PT; Bokrétás GP; Rácz E; Buzogány I; Bajory Z; Hajdú E; Molnár Z
Trials; 2017 Aug; 18(1):375. PubMed ID: 28800778
[TBL] [Abstract][Full Text] [Related]
17. Pulmonary oxygen exchange during endobronchial anesthesia: effect of tidal volume and PEEP.
Katz JA; Laverne RG; Fairley HB; Thomas AN
Anesthesiology; 1982 Mar; 56(3):164-71. PubMed ID: 7036798
[TBL] [Abstract][Full Text] [Related]
18. Protective intraoperative ventilation with higher versus lower levels of positive end-expiratory pressure in obese patients (PROBESE): study protocol for a randomized controlled trial.
Bluth T; Teichmann R; Kiss T; Bobek I; Canet J; Cinnella G; De Baerdemaeker L; Gregoretti C; Hedenstierna G; Hemmes SN; Hiesmayr M; Hollmann MW; Jaber S; Laffey JG; Licker MJ; Markstaller K; Matot I; Müller G; Mills GH; Mulier JP; Putensen C; Rossaint R; Schmitt J; Senturk M; Serpa Neto A; Severgnini P; Sprung J; Vidal Melo MF; Wrigge H; Schultz MJ; Pelosi P; Gama de Abreu M; ; ;
Trials; 2017 Apr; 18(1):202. PubMed ID: 28454590
[TBL] [Abstract][Full Text] [Related]
19. Variable versus conventional lung protective mechanical ventilation during open abdominal surgery (PROVAR): a randomised controlled trial.
Spieth PM; Güldner A; Uhlig C; Bluth T; Kiss T; Conrad C; Bischlager K; Braune A; Huhle R; Insorsi A; Tarantino F; Ball L; Schultz MJ; Abolmaali N; Koch T; Pelosi P; Gama de Abreu M;
Br J Anaesth; 2018 Mar; 120(3):581-591. PubMed ID: 29452815
[TBL] [Abstract][Full Text] [Related]
20. The effects of intraoperative lung protective ventilation with positive end-expiratory pressure on blood loss during hepatic resection surgery: A secondary analysis of data from a published randomised control trial (IMPROVE).
Neuschwander A; Futier E; Jaber S; Pereira B; Eurin M; Marret E; Szymkewicz O; Beaussier M; Paugam-Burtz C
Eur J Anaesthesiol; 2016 Apr; 33(4):292-8. PubMed ID: 26716865
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]