BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

345 related articles for article (PubMed ID: 26824382)

  • 1. Very late ischemic complications in flow-diverter stents: a retrospective analysis of a single-center series.
    Guédon A; Clarençon F; Di Maria F; Rosso C; Biondi A; Gabrieli J; Rojas P; Chiras J; Sourour N
    J Neurosurg; 2016 Oct; 125(4):929-935. PubMed ID: 26824382
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffusion-weighted imaging-detected ischemic lesions associated with flow-diverting stents in intracranial aneurysms: safety, potential mechanisms, clinical outcome, and concerns.
    Iosif C; Camilleri Y; Saleme S; Caire F; Yardin C; Ponomarjova S; Boncoeur-Martel MP; Mounayer C
    J Neurosurg; 2015 Mar; 122(3):627-36. PubMed ID: 25559933
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center.
    Briganti F; Leone G; Cirillo L; de Divitiis O; Solari D; Cappabianca P
    Neurosurg Focus; 2017 Jun; 42(6):E3. PubMed ID: 28565988
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: complications, aneurysm sac occlusion, reabsorption, recurrence, and jailed branch modification at follow-up.
    Michelozzi C; Darcourt J; Guenego A; Januel AC; Tall P; Gawlitza M; Bonneville F; Cognard C
    J Neurosurg; 2018 Dec; 131(6):1751-1762. PubMed ID: 30579280
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Patency of anterior circulation branch vessels after Pipeline embolization: longer-term results from 82 aneurysm cases.
    Rangel-Castilla L; Munich SA; Jaleel N; Cress MC; Krishna C; Sonig A; Snyder KV; Siddiqui AH; Levy EI
    J Neurosurg; 2017 Apr; 126(4):1064-1069. PubMed ID: 27285547
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.
    Xiang J; Damiano RJ; Lin N; Snyder KV; Siddiqui AH; Levy EI; Meng H
    J Neurosurg; 2015 Oct; 123(4):832-40. PubMed ID: 26090829
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of ischemic lesion prevalence after endovascular treatment of intracranial aneurysms, as documented by 3-T diffusion-weighted imaging: a 2-year, single-center cohort study.
    Iosif C; Lecomte JC; Pedrolo-Silveira E; Mendes G; Boncoeur Martel MP; Saleme S; Mounayer C
    J Neurosurg; 2018 Apr; 128(4):982-991. PubMed ID: 28598274
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The safety of Pipeline flow diversion in fusiform vertebrobasilar aneurysms: a consecutive case series with longer-term follow-up from a single US center.
    Natarajan SK; Lin N; Sonig A; Rai AT; Carpenter JS; Levy EI; Siddiqui AH
    J Neurosurg; 2016 Jul; 125(1):111-9. PubMed ID: 26654175
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow diverter stents for unruptured saccular anterior circulation perforating artery aneurysms: safety, efficacy, and short-term follow-up.
    Kühn AL; Hou SY; Perras M; Brooks C; Gounis MJ; Wakhloo AK; Puri AS
    J Neurointerv Surg; 2015 Sep; 7(9):634-40. PubMed ID: 25051964
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety and efficacy of the Pipeline Embolization Device in 100 small intracranial aneurysms.
    Chalouhi N; Zanaty M; Whiting A; Yang S; Tjoumakaris S; Hasan D; Starke RM; Hann S; Hammer C; Kung D; Rosenwasser R; Jabbour P
    J Neurosurg; 2015 Jun; 122(6):1498-502. PubMed ID: 25635478
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Patency of the anterior choroidal artery covered with a flow-diverter stent.
    Neki H; Caroff J; Jittapiromsak P; Benachour N; Mihalea C; Ikka L; Moret J; Spelle L
    J Neurosurg; 2015 Dec; 123(6):1540-5. PubMed ID: 26047410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pipeline flow diversion of ruptured blister aneurysms of the supraclinoid carotid artery using a single-device strategy.
    Ryan RW; Khan AS; Barco R; Choulakian A
    Neurosurg Focus; 2017 Jun; 42(6):E11. PubMed ID: 28565992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry.
    Brinjikji W; Kallmes DF; Cloft HJ; Lanzino G
    J Neurosurg; 2016 Jun; 124(6):1726-30. PubMed ID: 26544776
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Resolution of cranial neuropathies following treatment of intracranial aneurysms with the Pipeline Embolization Device.
    Moon K; Albuquerque FC; Ducruet AF; Crowley RW; McDougall CG
    J Neurosurg; 2014 Nov; 121(5):1085-92. PubMed ID: 25192477
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incidence of cerebral ischemic events after discontinuation of clopidogrel in patients with intracranial aneurysms treated with stent-assisted techniques.
    Rossen JD; Chalouhi N; Wassef SN; Thomas J; Abel TJ; Jabbour PM; Kung DK; Hasan DM
    J Neurosurg; 2012 Nov; 117(5):929-33. PubMed ID: 22957528
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative Assessment of In-Stent Stenosis After Pipeline Embolization Device Treatment of Intracranial Aneurysms: A Single-Institution Series and Systematic Review.
    Ravindran K; Salem MM; Enriquez-Marulanda A; Alturki AY; Moore JM; Thomas AJ; Ogilvy CS
    World Neurosurg; 2018 Dec; 120():e1031-e1040. PubMed ID: 30201581
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes after coverage of lenticulostriate vessels by flow diverters: a multicenter experience.
    Wagner KM; Srinivasan VM; Srivatsan A; Ghali MGZ; Thomas AJ; Enriquez-Marulanda A; Alturki AY; Ogilvy CS; Mokin M; Kuhn AL; Puri A; Grandhi R; Chen S; Johnson J; Kan P
    J Neurosurg; 2019 Jan; 132(2):473-480. PubMed ID: 30641842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flow diverter for endovascular treatment of intracranial mirror segment internal carotid artery aneurysms.
    Kühn AL; Kan P; Srinivasan V; Rex DE; de Macedo Rodrigues K; Howk MC; Wakhloo AK; Puri AS
    Interv Neuroradiol; 2019 Feb; 25(1):4-11. PubMed ID: 30081693
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flow Diverter Therapy Using a Pipeline Embolization Device for 100 Unruptured Large and Giant Internal Carotid Artery Aneurysms in a Single Center in a Japanese Population.
    Oishi H; Teranishi K; Yatomi K; Fujii T; Yamamoto M; Arai H
    Neurol Med Chir (Tokyo); 2018 Nov; 58(11):461-467. PubMed ID: 30298832
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow Diverter Stents for the Treatment of Anterior Cerebral Artery Aneurysms: Safety and Effectiveness.
    Clarençon F; Di Maria F; Gabrieli J; Shotar E; Zeghal C; Nouet A; Chiras J; Sourour NA
    Clin Neuroradiol; 2017 Mar; 27(1):51-56. PubMed ID: 26250557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.