BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

298 related articles for article (PubMed ID: 26825810)

  • 1. Characterization of a novel bioreactor system for 3D cellular mechanobiology studies.
    Cook CA; Huri PY; Ginn BP; Gilbert-Honick J; Somers SM; Temple JP; Mao HQ; Grayson WL
    Biotechnol Bioeng; 2016 Aug; 113(8):1825-37. PubMed ID: 26825810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Creating homogenous strain distribution within 3D cell-encapsulated constructs using a simple and cost-effective uniaxial tensile bioreactor: Design and validation study.
    Subramanian G; Elsaadany M; Bialorucki C; Yildirim-Ayan E
    Biotechnol Bioeng; 2017 Aug; 114(8):1878-1887. PubMed ID: 28425561
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel bioreactor for the generation of highly aligned 3D skeletal muscle-like constructs through orientation of fibrin via application of static strain.
    Heher P; Maleiner B; Prüller J; Teuschl AH; Kollmitzer J; Monforte X; Wolbank S; Redl H; Rünzler D; Fuchs C
    Acta Biomater; 2015 Sep; 24():251-65. PubMed ID: 26141153
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bioreactor Platform for Biomimetic Culture and
    Massai D; Pisani G; Isu G; Rodriguez Ruiz A; Cerino G; Galluzzi R; Pisanu A; Tonoli A; Bignardi C; Audenino AL; Marsano A; Morbiducci U
    Front Bioeng Biotechnol; 2020; 8():733. PubMed ID: 32766218
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new bioreactor for the controlled application of complex mechanical stimuli for cartilage tissue engineering.
    Laganà K; Moretti M; Dubini G; Raimondi MT
    Proc Inst Mech Eng H; 2008 Jul; 222(5):705-15. PubMed ID: 18756689
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New pulsatile hydrostatic pressure bioreactor for vascular tissue-engineered constructs.
    Shaikh FM; O'Brien TP; Callanan A; Kavanagh EG; Burke PE; Grace PA; McGloughlin TM
    Artif Organs; 2010 Feb; 34(2):153-8. PubMed ID: 19995361
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Principles and design of a novel magnetic force mechanical conditioning bioreactor for tissue engineering, stem cell conditioning, and dynamic in vitro screening.
    Dobson J; Cartmell SH; Keramane A; El Haj AJ
    IEEE Trans Nanobioscience; 2006 Sep; 5(3):173-7. PubMed ID: 16999242
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dynamic Bioreactors with Integrated Microfabricated Devices for Mechanobiological Screening.
    Beca BM; Sun Y; Wong E; Moraes C; Simmons CA
    Tissue Eng Part C Methods; 2019 Oct; 25(10):581-592. PubMed ID: 31337285
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Perfusion Bioreactor System for Cell Seeding and Oxygen-Controlled Cultivation of Three-Dimensional Cell Cultures.
    Schmid J; Schwarz S; Meier-Staude R; Sudhop S; Clausen-Schaumann H; Schieker M; Huber R
    Tissue Eng Part C Methods; 2018 Oct; 24(10):585-595. PubMed ID: 30234443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Myoblast maturity on aligned microfiber bundles at the onset of strain application impacts myogenic outcomes.
    Somers SM; Zhang NY; Morrissette-McAlmon JBF; Tran K; Mao HQ; Grayson WL
    Acta Biomater; 2019 Aug; 94():232-242. PubMed ID: 31212110
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel method to improve vascularization of tissue engineered constructs with biodegradable fibers.
    Wong HK; Ivan Lam CR; Wen F; Mark Chong SK; Tan NS; Jerry C; Pal M; Tan LP
    Biofabrication; 2016 Jan; 8(1):015004. PubMed ID: 26741237
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel perfusion bioreactor providing a homogenous milieu for tissue regeneration.
    Dvir T; Benishti N; Shachar M; Cohen S
    Tissue Eng; 2006 Oct; 12(10):2843-52. PubMed ID: 17518653
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and biological validation of a cyclic stretch culture system for the ex vivo engineering of tendons.
    Raimondi MT; Laganà M; Conci C; Crestani M; Di Giancamillo A; Gervaso F; Deponti D; Boschetti F; Nava MM; Scandone C; Domeneghini C; Sannino A; Peretti GM
    Int J Artif Organs; 2018 Jul; 41(7):400-412. PubMed ID: 29781355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Bioreactor to Identify the Driving Mechanical Stimuli of Tissue Growth and Remodeling.
    van Kelle MAJ; Oomen PJA; Bulsink JA; Janssen-van den Broek MWJT; Lopata RGP; Rutten MCM; Loerakker S; Bouten CVC
    Tissue Eng Part C Methods; 2017 Jun; 23(6):377-387. PubMed ID: 28478703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Adipose-derived stem cells cultivated on electrospun l-lactide/glycolide copolymer fleece and gelatin hydrogels under flow conditions - aiming physiological reality in hypodermis tissue engineering.
    Gugerell A; Neumann A; Kober J; Tammaro L; Hoch E; Schnabelrauch M; Kamolz L; Kasper C; Keck M
    Burns; 2015 Feb; 41(1):163-71. PubMed ID: 25440846
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel bioreactor for ligament tissue engineering.
    Kahn CJ; Vaquette C; Rahouadj R; Wang X
    Biomed Mater Eng; 2008; 18(4-5):283-7. PubMed ID: 19065035
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of pulsatile bioreactor culture on vascular smooth muscle cells seeded on electrospun poly (lactide-co-ε-caprolactone) scaffold.
    Mun CH; Jung Y; Kim SH; Kim HC; Kim SH
    Artif Organs; 2013 Dec; 37(12):E168-78. PubMed ID: 23834728
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cyclic flexure and laminar flow synergistically accelerate mesenchymal stem cell-mediated engineered tissue formation: Implications for engineered heart valve tissues.
    Engelmayr GC; Sales VL; Mayer JE; Sacks MS
    Biomaterials; 2006 Dec; 27(36):6083-95. PubMed ID: 16930686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro localization of bone growth factors in constructs of biodegradable scaffolds seeded with marrow stromal cells and cultured in a flow perfusion bioreactor.
    Gomes ME; Bossano CM; Johnston CM; Reis RL; Mikos AG
    Tissue Eng; 2006 Jan; 12(1):177-88. PubMed ID: 16499454
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design and characterization of a modified T-flask bioreactor for continuous monitoring of engineered tissue stiffness.
    Lasher RA; Wolchok JC; Parikh MK; Kennedy JP; Hitchcock RW
    Biotechnol Prog; 2010; 26(3):857-64. PubMed ID: 20187075
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.