122 related articles for article (PubMed ID: 26828368)
1. Computed modeling of humeral mid-shaft fracture treated by bundle nailing.
Obruba P; Capek L; Henys P; Kopp L
Comput Methods Biomech Biomed Engin; 2016 Oct; 19(13):1371-7. PubMed ID: 26828368
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical comparison of antegrade and retrograde nailing of humeral shaft fracture.
Lin J; Inoue N; Valdevit A; Hang YS; Hou SM; Chao EY
Clin Orthop Relat Res; 1998 Jun; (351):203-13. PubMed ID: 9646764
[TBL] [Abstract][Full Text] [Related]
3. [Treatment of humeral shaft fractures using Hackethal's technique of intramedullary bundle nailing].
Obruba P; Kopp L; Edelmann K
Acta Chir Orthop Traumatol Cech; 2012; 79(4):341-6. PubMed ID: 22980933
[TBL] [Abstract][Full Text] [Related]
4. Bending and torsional stiffness in cadaver humeri fixed with a self-locking expandable or interlocking nail system: a mechanical study.
Steinberg EL
J Orthop Trauma; 2006 Apr; 20(4):295; author reply 295-6. PubMed ID: 16721250
[No Abstract] [Full Text] [Related]
5. [Biomechanics of interlocked nailing in humeral shaft fractures. Comparison of 2 nail systems and the effect of interfragmentary compression with the unreamed humeral nail].
Blum J; Machemer H; Högner M; Baumgart F; Schlegel U; Wahl D; Rommens PM
Unfallchirurg; 2000 Mar; 103(3):183-90. PubMed ID: 10800380
[TBL] [Abstract][Full Text] [Related]
6. A biomechanical comparison of intramedullary nailing systems for the humerus.
Dalton JE; Salkeld SL; Satterwhite YE; Cook SD
J Orthop Trauma; 1993; 7(4):367-74. PubMed ID: 8377049
[TBL] [Abstract][Full Text] [Related]
7. [Unreamed locking intramedullary nailing of humeral fractures--basic evaluation of a patient group].
Fric V; Pazdírek P; Bartonícek J
Acta Chir Orthop Traumatol Cech; 2001; 68(6):345-56. PubMed ID: 11847926
[TBL] [Abstract][Full Text] [Related]
8. Complications after interlocking intramedullary nailing of humeral shaft fractures.
Baltov A; Mihail R; Dian E
Injury; 2014 Jan; 45 Suppl 1():S9-S15. PubMed ID: 24262669
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of bending and torsional properties in retrograde intramedullary nailing of humeral shaft fractures.
Blum J; Machemer H; Baumgart F; Schlegel U; Wahl D; Rommens PM
J Orthop Trauma; 1999; 13(5):344-50. PubMed ID: 10406701
[TBL] [Abstract][Full Text] [Related]
10. Intramedullary nailing in humeral shaft fractures. Mechanical behavior in vitro after osteosynthesis with three different intramedullary nails.
Mølster A; Gjerdet NR; Strand RM; Hole RM; Hove LM
Arch Orthop Trauma Surg; 2001 Nov; 121(10):554-6. PubMed ID: 11768634
[TBL] [Abstract][Full Text] [Related]
11. Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation.
Chen AL; Joseph TN; Wolinksy PR; Tejwani NC; Kummer FJ; Egol KA; Koval KJ
J Trauma; 2002 Oct; 53(4):733-7. PubMed ID: 12394875
[TBL] [Abstract][Full Text] [Related]
12. Bending and torsional stiffness in cadaver humeri fixed with a self-locking expandable or interlocking nail system: a mechanical study.
Blum J; Karagül G; Sternstein W; Rommens PM
J Orthop Trauma; 2005 Sep; 19(8):535-42. PubMed ID: 16118561
[TBL] [Abstract][Full Text] [Related]
13. A biomechanical analysis of four humeral fracture fixation systems.
Zimmerman MC; Waite AM; Deehan M; Tovey J; Oppenheim W
J Orthop Trauma; 1994; 8(3):233-9. PubMed ID: 8027893
[TBL] [Abstract][Full Text] [Related]
14. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps.
Chen YN; Lee PY; Chang CH; Chang CW; Ho YH; Li CT; Peng YT
Injury; 2016 Oct; 47(10):2339-2346. PubMed ID: 27424533
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.
Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):803-10. PubMed ID: 24951320
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
[TBL] [Abstract][Full Text] [Related]
17. [Intramedullary fixation of humerus shaft fractures. An analysis of complications of 2 implants with special reference to outcome after management with the unreamed humerus interlocking nail].
Vécsei N; Kolonja A; Mousavi M; Vécsei V
Wien Klin Wochenschr; 2001 Aug; 113(15-16):597-604. PubMed ID: 11571838
[TBL] [Abstract][Full Text] [Related]
18. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.
Gessmann J; Königshausen M; Coulibaly MO; Schildhauer TA; Seybold D
Arch Orthop Trauma Surg; 2016 May; 136(5):631-8. PubMed ID: 26852379
[TBL] [Abstract][Full Text] [Related]
19. [Intramedullary nailing of the humerus as an alternative to conservative therapy and to plate osteosynthesis].
Kessler SB; Nast-Kolb D; Brunner U; Wischhöfer E
Orthopade; 1996 Jun; 25(3):216-22. PubMed ID: 8766660
[TBL] [Abstract][Full Text] [Related]
20. Results of the T2 humeral nailing system with special focus on compression interlocking.
Mückley T; Diefenbeck M; Sorkin AT; Beimel C; Goebel M; Bühren V
Injury; 2008 Mar; 39(3):299-305. PubMed ID: 18164298
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]