These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Reduced liner-open phase and vacuum instead of prestimulation increase parlor efficiency in dairy cows. Tuor M; Jenni B; Wellnitz O; Bruckmaier RM J Dairy Sci; 2022 Feb; 105(2):1533-1541. PubMed ID: 34955277 [TBL] [Abstract][Full Text] [Related]
6. Effects of a latency period between pre-stimulation and teat cup attachment and periodic vacuum reduction on milking characteristics and teat condition in dairy cows. Vetter A; van Dorland HA; Youssef M; Bruckmaier RM J Dairy Res; 2014 Feb; 81(1):107-12. PubMed ID: 24433587 [TBL] [Abstract][Full Text] [Related]
7. Short communication: Teat wall diameter and teat tissue thickness in dairy cows are affected by intramammary pressure and by the mechanical forces of machine milking. Odorcic M; Blau U; Löfstrand J; Bruckmaier RM J Dairy Sci; 2020 Jan; 103(1):884-889. PubMed ID: 31733859 [TBL] [Abstract][Full Text] [Related]
8. A method for assessing teatcup liner performance during the peak milk flow period. Penry JF; Upton J; Leonardi S; Thompson PD; Reinemann DJ J Dairy Sci; 2018 Jan; 101(1):649-660. PubMed ID: 29102142 [TBL] [Abstract][Full Text] [Related]
9. The interplay of continuous milk ejection and milking system with and without prestimulation at different vacuum settings. Tuor M; Wellnitz O; Bruckmaier RM J Dairy Sci; 2023 May; 106(5):3615-3624. PubMed ID: 37002133 [TBL] [Abstract][Full Text] [Related]
10. Type of teat cup liner and cluster ventilation affect vacuum conditions in the liner and milking performance in dairy cows. Holst GE; Adrion F; Umstätter C; Bruckmaier RM J Dairy Sci; 2021 Apr; 104(4):4775-4786. PubMed ID: 33612232 [TBL] [Abstract][Full Text] [Related]
11. Effects of milkline vacuum, pulsator airline vacuum, and cluster weight on milk yield, teat condition, and udder health. Rasmussen MD; Madsen NP J Dairy Sci; 2000 Jan; 83(1):77-84. PubMed ID: 10659967 [TBL] [Abstract][Full Text] [Related]
12. Milk-flow data collected routinely in an automatic milking system: an alternative to milking-time testing in the management of teat-end condition? Nørstebø H; Rachah A; Dalen G; Rønningen O; Whist AC; Reksen O Acta Vet Scand; 2018 Jan; 60(1):2. PubMed ID: 29325588 [TBL] [Abstract][Full Text] [Related]
13. Teat tissue reactions to milking: effects of vacuum level. Hamann J; Mein GA; Wetzel S J Dairy Sci; 1993 Apr; 76(4):1040-6. PubMed ID: 8486836 [TBL] [Abstract][Full Text] [Related]
14. A longitudinal prospective cohort study investigating the association of premilking stimulation and teat-end shape on milking characteristics and teat tissue condition in dairy cows. Wieland M; Melvin JM; Nydam DV; Virkler PD BMC Vet Res; 2019 Feb; 15(1):58. PubMed ID: 30755196 [TBL] [Abstract][Full Text] [Related]
15. A randomized controlled trial to study the effects of an automated premilking stimulation system on milking performance, teat tissue condition, and udder health in Holstein dairy cows. Wieland M; Geary CM; Nydam DV; Virkler PD; Zurakowski M; Watters RD; Lynch R J Dairy Sci; 2023 Sep; 106(9):6551-6566. PubMed ID: 37500447 [TBL] [Abstract][Full Text] [Related]
16. A randomized trial to study the effect of automatic cluster remover settings on milking performance, teat condition, and udder health. Wieland M; Nydam DV; Heuwieser W; Morrill KM; Ferlito L; Watters RD; Virkler PD J Dairy Sci; 2020 Apr; 103(4):3668-3682. PubMed ID: 32008782 [TBL] [Abstract][Full Text] [Related]
17. Bimodal milk flow and overmilking in dairy cattle: risk factors and consequences. Fernandes S; Pereira G; Bexiga R Animal; 2023 Mar; 17(3):100716. PubMed ID: 36791490 [TBL] [Abstract][Full Text] [Related]
18. Effect of hydraulic milking on milking performance, teat condition and lipolysis. Grindal RJ; Griffin TK J Dairy Res; 1989 Feb; 56(1):45-53. PubMed ID: 2703561 [TBL] [Abstract][Full Text] [Related]