BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 26831923)

  • 1. Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer.
    Öğretici A; Akbaş U; Köksal C; Bilge H
    Med Dosim; 2016; 41(2):95-9. PubMed ID: 26831923
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Constituent components of out-of-field scatter dose for 18-MV intensity modulated radiation therapy versus 3-dimensional conformal radiation therapy: a comparison with 6-MV and implications for carcinogenesis.
    Ruben JD; Smith R; Lancaster CM; Haynes M; Jones P; Panettieri V
    Int J Radiat Oncol Biol Phys; 2014 Nov; 90(3):645-53. PubMed ID: 25084609
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical dosimetric study of three radiotherapy techniques for postoperative breast cancer: Helical Tomotherapy, IMRT, and 3D-CRT.
    Zhou GX; Xu SP; Dai XK; Ju ZJ; Gong HS; Xie CB; Yin LM; Yang J
    Technol Cancer Res Treat; 2011 Feb; 10(1):15-23. PubMed ID: 21214284
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical implementation of tangential field intensity modulated radiation therapy (IMRT) using sliding window technique and dosimetric comparison with 3D conformal therapy (3DCRT) in breast cancer.
    Selvaraj RN; Beriwal S; Pourarian RJ; Lalonde RJ; Chen A; Mehta K; Brunner G; Wagner KA; Yue NJ; Huq SM; Heron DE
    Med Dosim; 2007; 32(4):299-304. PubMed ID: 17980832
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is intensity-modulated radiotherapy better than conventional radiation treatment and three-dimensional conformal radiotherapy for mediastinal masses in patients with Hodgkin's disease, and is there a role for beam orientation optimization and dose constraints assigned to virtual volumes?
    Girinsky T; Pichenot C; Beaudre A; Ghalibafian M; Lefkopoulos D
    Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):218-26. PubMed ID: 16169675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric comparison of 3D conformal, IMRT, and V-MAT techniques for accelerated partial-breast irradiation (APBI).
    Qiu JJ; Chang Z; Horton JK; Wu QR; Yoo S; Yin FF
    Med Dosim; 2014; 39(2):152-8. PubMed ID: 24480375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation treatment planning and delivery strategies for a pregnant brain tumor patient.
    Labby ZE; Barraclough B; Bayliss RA; Besemer AE; Dunkerley DAP; Howard SP
    J Appl Clin Med Phys; 2018 Sep; 19(5):368-374. PubMed ID: 30062720
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT.
    Reft CS; Runkel-Muller R; Myrianthopoulos L
    Med Phys; 2006 Oct; 33(10):3734-42. PubMed ID: 17089839
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric comparison of four different external beam partial breast irradiation techniques: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy.
    Moon SH; Shin KH; Kim TH; Yoon M; Park S; Lee DH; Kim JW; Kim DW; Park SY; Cho KH
    Radiother Oncol; 2009 Jan; 90(1):66-73. PubMed ID: 18992950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment of left sided breast cancer for a patient with funnel chest: volumetric-modulated arc therapy vs. 3D-CRT and intensity-modulated radiotherapy.
    Haertl PM; Pohl F; Weidner K; Groeger C; Koelbl O; Dobler B
    Med Dosim; 2013; 38(1):1-4. PubMed ID: 22727550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An imrt technique to increase therapeutic ratio of breast irradiation in patients with early-stage left breast cancer: limiting second malignancies.
    Ahmed RS; De Los Santos JF; Fiveash JB; Keene KS; Popple RA
    Med Dosim; 2008; 33(1):71-7. PubMed ID: 18262126
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tomotherapy and multifield intensity-modulated radiotherapy planning reduce cardiac doses in left-sided breast cancer patients with unfavorable cardiac anatomy.
    Coon AB; Dickler A; Kirk MC; Liao Y; Shah AP; Strauss JB; Chen S; Turian J; Griem KL
    Int J Radiat Oncol Biol Phys; 2010 Sep; 78(1):104-10. PubMed ID: 20004529
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: how do protons compare with other conformal techniques?
    Lee CT; Bilton SD; Famiglietti RM; Riley BA; Mahajan A; Chang EL; Maor MH; Woo SY; Cox JD; Smith AR
    Int J Radiat Oncol Biol Phys; 2005 Oct; 63(2):362-72. PubMed ID: 16168831
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation.
    van der Laan HP; Korevaar EW; Dolsma WV; Maduro JH; Langendijk JA
    Radiother Oncol; 2010 Feb; 94(2):235-40. PubMed ID: 20080312
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT).
    Wang X; Li G; Zhang Y; Bai S; Xu F; Wei Y; Gong Y
    Med Dosim; 2013; 38(4):395-400. PubMed ID: 23791504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prone hypofractionated whole-breast radiotherapy without a boost to the tumor bed: comparable toxicity of IMRT versus a 3D conformal technique.
    Hardee ME; Raza S; Becker SJ; Jozsef G; Lymberis SC; Hochman T; Goldberg JD; DeWyngaert KJ; Formenti SC
    Int J Radiat Oncol Biol Phys; 2012 Mar; 82(3):e415-23. PubMed ID: 22019349
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multileaf field-in-field forward-planned intensity-modulated dose compensation for whole-breast irradiation is associated with reduced contralateral breast dose: a phantom model comparison.
    Borghero YO; Salehpour M; McNeese MD; Stovall M; Smith SA; Johnson J; Perkins GH; Strom EA; Oh JL; Kirsner SM; Woodward WA; Yu TK; Buchholz TA
    Radiother Oncol; 2007 Mar; 82(3):324-8. PubMed ID: 17157944
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Effect of Flattening Filter Free on Three-dimensional Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) Plans for Metastatic Brain Tumors from Non-small Cell Lung Cancer.
    Shi LW; Lai YQ; Lin Q; Ha HM; Fu LR
    Health Phys; 2015 Jul; 109(1):1-9. PubMed ID: 26011493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric comparison of left-sided whole breast irradiation with 3D-CRT, IP-IMRT and hybrid IMRT.
    Xie X; Ouyang S; Wang H; Yang W; Jin H; Hu B; Shen L
    Oncol Rep; 2014 May; 31(5):2195-205. PubMed ID: 24604635
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lens dose in MLC-based IMRT treatments of the head and neck.
    Pawlicki T; Luxton G; Le QT; Findley D; Ma CM
    Int J Radiat Oncol Biol Phys; 2004 May; 59(1):293-9. PubMed ID: 15093926
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.