These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 26836274)

  • 1. Towards breast tomography with synchrotron radiation at Elettra: first images.
    Longo R; Arfelli F; Bellazzini R; Bottigli U; Brez A; Brun F; Brunetti A; Delogu P; Di Lillo F; Dreossi D; Fanti V; Fedon C; Golosio B; Lanconelli N; Mettivier G; Minuti M; Oliva P; Pinchera M; Rigon L; Russo P; Sarno A; Spandre G; Tromba G; Zanconati F
    Phys Med Biol; 2016 Feb; 61(4):1634-49. PubMed ID: 26836274
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector.
    Sarno A; Mettivier G; Golosio B; Oliva P; Spandre G; Di Lillo F; Fedon C; Longo R; Russo P
    Phys Med; 2016 May; 32(5):681-90. PubMed ID: 27160829
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study.
    Brombal L; Arfelli F; Delogu P; Donato S; Mettivier G; Michielsen K; Oliva P; Taibi A; Sechopoulos I; Longo R; Fedon C
    Sci Rep; 2019 Nov; 9(1):17778. PubMed ID: 31780707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.
    Brombal L; Golosio B; Arfelli F; Bonazza D; Contillo A; Delogu P; Donato S; Mettivier G; Oliva P; Rigon L; Taibi A; Tromba G; Zanconati F; Longo R
    J Med Imaging (Bellingham); 2019 Jul; 6(3):031402. PubMed ID: 30525064
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimization of a customized simultaneous algebraic reconstruction technique algorithm for phase-contrast breast computed tomography.
    Donato S; Brombal L; Arana Peña LM; Arfelli F; Contillo A; Delogu P; Di Lillo F; Di Trapani V; Fanti V; Longo R; Oliva P; Rigon L; Stori L; Tromba G; Golosio B
    Phys Med Biol; 2022 Apr; 67(9):. PubMed ID: 35395648
    [No Abstract]   [Full Text] [Related]  

  • 6. Image quality evaluation of breast tomosynthesis with synchrotron radiation.
    Malliori A; Bliznakova K; Speller RD; Horrocks JA; Rigon L; Tromba G; Pallikarakis N
    Med Phys; 2012 Sep; 39(9):5621-34. PubMed ID: 22957628
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra.
    Longo R; Arfelli F; Bonazza D; Bottigli U; Brombal L; Contillo A; Cova MA; Delogu P; Di Lillo F; Di Trapani V; Donato S; Dreossi D; Fanti V; Fedon C; Golosio B; Mettivier G; Oliva P; Pacilè S; Sarno A; Rigon L; Russo P; Taibi A; Tonutti M; Zanconati F; Tromba G
    J Synchrotron Radiat; 2019 Jul; 26(Pt 4):1343-1353. PubMed ID: 31274463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phase-contrast breast CT: the effect of propagation distance.
    Brombal L; Donato S; Dreossi D; Arfelli F; Bonazza D; Contillo A; Delogu P; Di Trapani V; Golosio B; Mettivier G; Oliva P; Rigon L; Taibi A; Longo R
    Phys Med Biol; 2018 Dec; 63(24):24NT03. PubMed ID: 30524112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A proposal for a quality control protocol in breast CT with synchrotron radiation.
    Contillo A; Veronese A; Brombal L; Donato S; Rigon L; Taibi A; Tromba G; Longo R; Arfelli F
    Radiol Oncol; 2018 Mar; 52(3):329-336. PubMed ID: 30210044
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Breast tomography with synchrotron radiation: preliminary results.
    Pani S; Longo R; Dreossi D; Montanari F; Olivo A; Arfelli F; Bergamaschi A; Poropat P; Rigon L; Zanconati F; Dalla Palma L; Castelli E
    Phys Med Biol; 2004 May; 49(9):1739-54. PubMed ID: 15152928
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology.
    Fiedler S; Bravin A; Keyriläinen J; Fernández M; Suortti P; Thomlinson W; Tenhunen M; Virkkunen P; Karjalainen-Lindsberg M
    Phys Med Biol; 2004 Jan; 49(2):175-88. PubMed ID: 15083665
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Propagation-based x-ray phase-contrast tomography of mastectomy samples using synchrotron radiation.
    Gureyev TE; Nesterets YI; Baran PM; Taba ST; Mayo SC; Thompson D; Arhatari B; Mihocic A; Abbey B; Lockie D; Fox J; Kumar B; Prodanovic Z; Hausermann D; Maksimenko A; Hall C; Peele AG; Dimmock M; Pavlov KM; Cholewa M; Lewis S; Tromba G; Quiney HM; Brennan PC
    Med Phys; 2019 Dec; 46(12):5478-5487. PubMed ID: 31574166
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Large-area single-photon-counting CdTe detector for synchrotron radiation computed tomography: a dedicated pre-processing procedure.
    Brombal L; Donato S; Brun F; Delogu P; Fanti V; Oliva P; Rigon L; Di Trapani V; Longo R; Golosio B
    J Synchrotron Radiat; 2018 Jul; 25(Pt 4):1068-1077. PubMed ID: 29979168
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Advantages of breast cancer visualization and characterization using synchrotron radiation phase-contrast tomography.
    Pacilè S; Baran P; Dullin C; Dimmock M; Lockie D; Missbach-Guntner J; Quiney H; McCormack M; Mayo S; Thompson D; Nesterets Y; Hall C; Pavlov K; Prodanovic Z; Tonutti M; Accardo A; Fox J; Tavakoli Taba S; Lewis S; Brennan P; Hausermann D; Tromba G; Gureyev T
    J Synchrotron Radiat; 2018 Sep; 25(Pt 5):1460-1466. PubMed ID: 30179186
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of breast imaging using synchrotron radiation.
    Fitousi NT; Delis H; Panayiotakis G
    Med Phys; 2012 Apr; 39(4):2069-77. PubMed ID: 22482628
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom.
    Ryu YJ; Choi YH; Cheon JE; Ha S; Kim WS; Kim IO
    Pediatr Radiol; 2016 Mar; 46(3):303-15. PubMed ID: 26546568
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Motion artifacts assessment and correction using optical tracking in synchrotron radiation breast CT.
    Brombal L; Arana Peña LM; Arfelli F; Longo R; Brun F; Contillo A; Di Lillo F; Tromba G; Di Trapani V; Donato S; Menk RH; Rigon L
    Med Phys; 2021 Sep; 48(9):5343-5355. PubMed ID: 34252212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging.
    Tavakoli Taba S; Baran P; Nesterets YI; Pacile S; Wienbeck S; Dullin C; Pavlov K; Maksimenko A; Lockie D; Mayo SC; Quiney HM; Dreossi D; Arfelli F; Tromba G; Lewis S; Gureyev TE; Brennan PC
    Eur Radiol; 2020 May; 30(5):2740-2750. PubMed ID: 31974689
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First application of computed radiology to mammography with synchrotron radiation.
    Quai E; Longo R; Zanconati F; Jaconelli G; Tonutti M; Abrami A; Arfelli F; Dreossi D; Tromba G; Cova MA
    Radiol Med; 2013 Feb; 118(1):89-100. PubMed ID: 22744351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology.
    Bravin A; Keyriläinen J; Fernández M; Fiedler S; Nemoz C; Karjalainen-Lindsberg ML; Tenhunen M; Virkkunen P; Leidenius M; von Smitten K; Sipilä P; Suortti P
    Phys Med Biol; 2007 Apr; 52(8):2197-211. PubMed ID: 17404464
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.