These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 26836862)

  • 1. Traceable methods for vertical scale characterization of dynamic stroboscopic scanning white-light interferometer measurements.
    Heikkinen V; Kassamakov I; Seppä J; Paulin T; Nolvi A; Lassila A; Hæggström E
    Appl Opt; 2015 Dec; 54(35):10397-403. PubMed ID: 26836862
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transfer standard for traceable dynamic calibration of stroboscopic scanning white light interferometer.
    Kassamakov I; Tureanu A; Heikkinen V; Hæggström E
    Appl Opt; 2017 Mar; 56(9):2483-2488. PubMed ID: 28375356
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stroboscopic scanning white light interferometry at 2.7 MHz with 1.6 µm coherence length using a non-phosphor LED source.
    Heikkinen V; Kassamakov I; Paulin T; Nolvi A; Hæggström E
    Opt Express; 2013 Mar; 21(5):5247-54. PubMed ID: 23482096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Invited article: Expanded and improved traceability of vibration measurements by laser interferometry.
    von Martens HJ
    Rev Sci Instrum; 2013 Dec; 84(12):121601. PubMed ID: 24387405
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-speed stroboscopic imaging with frequency-doubled supercontinuum.
    Ryczkowski P; Nolvi A; Kassamakov I; Genty G; Hæggström E
    Opt Lett; 2013 Mar; 38(5):658-60. PubMed ID: 23455256
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stroboscopic supercontinuum white-light interferometer for MEMS characterization.
    Hanhijärvi K; Kassamakov I; Heikkinen V; Aaltonen J; Sainiemi L; Grigoras K; Franssila S; Hæggström E
    Opt Lett; 2012 May; 37(10):1703-5. PubMed ID: 22627543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface topography acquisition method for double-sided near-right-angle structured surfaces based on dual-probe wavelength scanning interferometry.
    Zhang T; Gao F; Jiang X
    Opt Express; 2017 Oct; 25(20):24148-24156. PubMed ID: 29041360
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scanning white-light interferometry with a supercontinuum source.
    Kassamakov I; Hanhijärvi K; Abbadi I; Aaltonen J; Ludvigsen H; Haeggström E
    Opt Lett; 2009 May; 34(10):1582-4. PubMed ID: 19448828
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accurate laser wavelength measurement with a precision two-beam scanning Michelson interferometer.
    Monchalin JP; Kelly MJ; Thomas JE; Kurnit NA; Szöke A; Zernike F; Lee PH; Javan A
    Appl Opt; 1981 Mar; 20(5):736-57. PubMed ID: 20309198
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Absolute distance measurement using laser interferometric wavelength leverage with a dynamic-sideband-locked synthetic wavelength generation.
    Yan L; Xie J; Chen B; Lou Y; Zhang S
    Opt Express; 2021 Mar; 29(6):8344-8357. PubMed ID: 33820282
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accurate measurement of interferometer group delay using field-compensated scanning white light interferometer.
    Wan X; Wang J; Ge J
    Appl Opt; 2010 Oct; 49(29):5645-53. PubMed ID: 20935712
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3D push-pull heterodyne interferometer for SPM metrology.
    Kazieva TV; Gubskiy KL; Kuznetsov AP; Reshetov VN
    Appl Opt; 2019 May; 58(15):4000-4006. PubMed ID: 31158154
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interference comparator for laser diode wavelength and wavelength instability measurement.
    Dobosz M; Kożuchowski M
    Rev Sci Instrum; 2016 Apr; 87(4):043115. PubMed ID: 27131662
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-channel absolute distance measurement system with sub ppm-accuracy and 20 m range using frequency scanning interferometry and gas absorption cells.
    Dale J; Hughes B; Lancaster AJ; Lewis AJ; Reichold AJ; Warden MS
    Opt Express; 2014 Oct; 22(20):24869-93. PubMed ID: 25322060
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relative optical wavefront measurement in displacement measuring interferometer systems with sub-nm precision.
    Meskers AJ; Voigt D; Spronck JW
    Opt Express; 2013 Jul; 21(15):17920-30. PubMed ID: 23938664
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated, Speckle-Based Displacement Measurement for Lateral Scanning White Light Interferometry.
    Behrends G; Stöbener D; Fischer A
    Sensors (Basel); 2021 Apr; 21(7):. PubMed ID: 33918507
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry.
    Wang G; Tan L; Yan S
    Sensors (Basel); 2018 Feb; 18(2):. PubMed ID: 29414897
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Precision displacement measurement by active laser heterodyne interferometry.
    Lin YJ; Pan CL
    Appl Opt; 1991 May; 30(13):1648-52. PubMed ID: 20700338
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of surface acoustic waves by stroboscopic white-light interferometry.
    Kokkonen K; Lipiäinen L; Shavrin I; Novotny S; Kaivola M; Ludvigsen H
    Opt Express; 2015 Apr; 23(8):9690-5. PubMed ID: 25969006
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Picosecond supercontinuum light source for stroboscopic white-light interferometry with freely adjustable pulse repetition rate.
    Novotny S; Durairaj V; Shavrin I; Lipiäinen L; Kokkonen K; Kaivola M; Ludvigsen H
    Opt Express; 2014 Jun; 22(11):13625-33. PubMed ID: 24921556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.