These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 26838065)
1. SECONDARY STANDARD CALIBRATION, MEASUREMENT AND IRRADIATION CAPABILITIES OF THE INDIVIDUAL MONITORING SERVICE AT THE HELMHOLTZ ZENTRUM MÜNCHEN: ASPECTS OF UNCERTAINTY AND AUTOMATION. Greiter MB; Denk J; Hoedlmoser H Radiat Prot Dosimetry; 2016 Sep; 170(1-4):103-7. PubMed ID: 26838065 [TBL] [Abstract][Full Text] [Related]
2. A FULLY AUTOMATED SECONDARY STANDARD X-RAY CALIBRATION FACILITY FOR PERSONAL DOSEMETERS. Bandalo V; Brönner J; Greiter MB; Hoedlmoser H Radiat Prot Dosimetry; 2019 Jul; 184(1):73-78. PubMed ID: 30380117 [TBL] [Abstract][Full Text] [Related]
3. 2240 IRRADIATED PERSONAL DOSEMETERS FOR THE IC2014 EURADOS INTERCOMPARISON AT SEIBERSDORF. Hranitzky C Radiat Prot Dosimetry; 2016 Sep; 170(1-4):27-30. PubMed ID: 26311703 [TBL] [Abstract][Full Text] [Related]
4. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry. Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221 [TBL] [Abstract][Full Text] [Related]
5. Hp(0.07) photon irradiations at Seibersdorf for the EURADOS extremity dosemeter intercomparison 2009. Stadtmann H; Hranitzky C Radiat Prot Dosimetry; 2011 Mar; 144(1-4):306-9. PubMed ID: 21208935 [TBL] [Abstract][Full Text] [Related]
6. DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04. Haninger T; Henniger J Radiat Prot Dosimetry; 2016 Sep; 170(1-4):150-3. PubMed ID: 26405220 [TBL] [Abstract][Full Text] [Related]
7. Dose rate dependency of electronic personal dosemeters measuring X- and gamma-ray radiation. McCaffrey JP; Shen H; Downton B Radiat Prot Dosimetry; 2008; 131(2):229-35. PubMed ID: 18420561 [TBL] [Abstract][Full Text] [Related]
8. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related]
9. Dose rate constant of a cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry. Chen Z; Bongiorni P; Nath R Med Phys; 2005 Nov; 32(11):3279-85. PubMed ID: 16372409 [TBL] [Abstract][Full Text] [Related]
10. Deciding between an X-Ray and 137Cs Irradiator - It's not just about Energy Spectra. Murphy MK; Kamen J Radiat Res; 2019 Nov; 192(5):493-506. PubMed ID: 31502907 [TBL] [Abstract][Full Text] [Related]
11. RE-EVALUATION OF THE AIR KERMA PRIMARY STANDARD OF THE SMU IN 60Co AND 137Cs GAMMA RAY BEAMS. Durný N Radiat Prot Dosimetry; 2019 Dec; 186(2-3):235-238. PubMed ID: 32123913 [TBL] [Abstract][Full Text] [Related]
12. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co. Snow JR; Micka JA; DeWerd LA Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881 [TBL] [Abstract][Full Text] [Related]
13. Feasibility study of the Fricke chemical dosimeter as an independent dosimetric system for the small animal radiation research platform (SARRP). Muñoz Arango E; Pickler A; Mantuano A; Salata C; de Almeida CE Phys Med; 2020 Mar; 71():168-175. PubMed ID: 32163885 [TBL] [Abstract][Full Text] [Related]
14. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES. Lopez MA; Martin R; Hernandez C; Navarro JF; Navarro T; Perez B; Sierra I Radiat Prot Dosimetry; 2016 Sep; 170(1-4):31-4. PubMed ID: 26433182 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of scattered radiation in a calibration range using exposure rate energy spectra. Petrie CM; Blue TE; Herminghuysen K Health Phys; 2012 Jan; 102(1):71-80. PubMed ID: 22134080 [TBL] [Abstract][Full Text] [Related]
17. [Development of the 60Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water (N(D,w))]. Fukumura A; Mizuno H; Fukahori M; Sakata S Igaku Butsuri; 2012; 32(4):182-8. PubMed ID: 24568023 [TBL] [Abstract][Full Text] [Related]
18. Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60Co. Lavallée MC; Gingras L; Beaulieu L Med Phys; 2006 Oct; 33(10):3683-9. PubMed ID: 17089834 [TBL] [Abstract][Full Text] [Related]
19. Dosimetric characterization of a 131Cs brachytherapy source by thermoluminescence dosimetry in liquid water. Tailor R; Ibbott G; Lampe S; Warren WB; Tolani N Med Phys; 2008 Dec; 35(12):5861-8. PubMed ID: 19175142 [TBL] [Abstract][Full Text] [Related]
20. DOSIMETRIC QUALITY ASSURANCE INTERPRETED FOR ISO 17025 IN PUBLIC HEALTH ENGLAND'S PERSONAL DOSIMETRY SERVICE. Gilvin PJ; Gibbens NJ; Baker ST Radiat Prot Dosimetry; 2016 Sep; 170(1-4):132-5. PubMed ID: 27150516 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]