These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 26839866)

  • 1. The Advantages and Disadvantages of Methods Used to Control Liver Bleeding: A Review.
    Nouri S; Sharif MR; Afzali H; Sharif A; Satkin M
    Trauma Mon; 2015 Nov; 20(4):e28088. PubMed ID: 26839866
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficacy and safety of ferric chloride in controlling hepatic bleeding; an animal model study.
    Nouri S; Sharif MR
    Hepat Mon; 2014 Jun; 14(6):e18652. PubMed ID: 24976842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prohemostatic interventions in liver surgery.
    Stellingwerff M; Brandsma A; Lisman T; Porte RJ
    Semin Thromb Hemost; 2012 Apr; 38(3):244-9. PubMed ID: 22510858
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of ferric sulfate to control hepatic bleeding.
    Nouri S; Sharif MR
    Trauma Mon; 2015 Feb; 20(1):e25257. PubMed ID: 25825702
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Analysis of opinion of surgeons on the role of topical hemostatic agents].
    Bondarev GA; Lipatov VA; Lazarenko SV; Severinov DA; Saakyan AR
    Khirurgiia (Mosk); 2020; (8):61-68. PubMed ID: 32869617
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safety and effectiveness of a synthetic hemostatic patch for intraoperative soft tissue bleeding.
    Schuhmacher C; Pratschke J; Weiss S; Schneeberger S; Mihaljevic AL; Schirren R; Winkler M; Emmanouilidis N
    Med Devices (Auckl); 2015; 8():167-74. PubMed ID: 25878513
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy and safety of aluminum chloride in controlling external hemorrhage: an animal model study.
    Nouri S; Sharif MR; Panahi Y; Ghanei M; Jamali B
    Iran Red Crescent Med J; 2015 Mar; 17(3):e19714. PubMed ID: 25964855
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adhesion prevention in gynaecological surgery.
    Robertson D; Lefebvre G;
    J Obstet Gynaecol Can; 2010 Jun; 32(6):598-602. PubMed ID: 20569542
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimizing blood loss during hepatectomy: a literature review.
    Huntington JT; Royall NA; Schmidt CR
    J Surg Oncol; 2014 Feb; 109(2):81-8. PubMed ID: 24449171
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemostatic Agents in Endodontic Surgery: A Randomized Controlled Pilot Study of Polytetrafluoroethylene Strips as an Adjunct to Epinephrine Impregnated Gauze Versus Aluminum Chloride.
    Peñarrocha-Oltra D; Soto-Peñaloza D; Peñarrocha-Diago M; Cervera-Ballester J; von Arx T; Peñarrocha-Diago M
    J Endod; 2019 Aug; 45(8):970-976. PubMed ID: 31160080
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a gelatin matrix as a topical hemostatic agent for hepatic bleeding in the dog.
    Polidoro DP; Kass PH
    J Am Anim Hosp Assoc; 2013; 49(5):308-17. PubMed ID: 23861265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of two topical collagen-based hemostatic sponges during cardiothoracic procedures.
    Zwischenberger JB; Brunston RL; Swann JR; Conti VR
    J Invest Surg; 1999; 12(2):101-6. PubMed ID: 10327079
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of ferric chloride on superficial bleeding.
    Nouri S; Sharif MR; Sahba S
    Trauma Mon; 2015 Feb; 20(1):e18042. PubMed ID: 25825694
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of fibrin-based sealants and gelatin-matrix hemostats in laparoscopic liver surgery.
    Saif R; Jacob M; Robinson S; Amer A; Kei-Hui D; Sen G; Manas D; White S
    Surg Laparosc Endosc Percutan Tech; 2011 Jun; 21(3):131-41. PubMed ID: 21654294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of a new fibrin sealant with standard topical hemostatic agents.
    Schwartz M; Madariaga J; Hirose R; Shaver TR; Sher L; Chari R; Colonna JO; Heaton N; Mirza D; Adams R; Rees M; Lloyd D
    Arch Surg; 2004 Nov; 139(11):1148-54. PubMed ID: 15545559
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Armentarium of topical hemostatic products in cardiovascular surgery: an update.
    Forcillo J; Perrault LP
    Transfus Apher Sci; 2014 Feb; 50(1):26-31. PubMed ID: 24412443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Techniques for liver parenchymal transection in liver resection.
    Gurusamy KS; Pamecha V; Sharma D; Davidson BR
    Cochrane Database Syst Rev; 2009 Jan; (1):CD006880. PubMed ID: 19160307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective, randomized clinical trial of the FloSeal matrix sealant in cardiac surgery.
    Nasso G; Piancone F; Bonifazi R; Romano V; Visicchio G; De Filippo CM; Impiombato B; Fiore F; Bartolomucci F; Alessandrini F; Speziale G
    Ann Thorac Surg; 2009 Nov; 88(5):1520-6. PubMed ID: 19853105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a novel hemostatic device in an ovine parenchymal organ bleeding model of normal and impaired hemostasis.
    Turner AS; Parker D; Egbert B; Maroney M; Armstrong R; Powers N
    J Biomed Mater Res; 2002; 63(1):37-47. PubMed ID: 11787027
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.