BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

555 related articles for article (PubMed ID: 26847116)

  • 1. Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve.
    Husser O; Pellegrini C; Kessler T; Burgdorf C; Thaller H; Mayr NP; Kasel AM; Kastrati A; Schunkert H; Hengstenberg C
    JACC Cardiovasc Interv; 2016 Feb; 9(3):244-254. PubMed ID: 26847116
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.
    Husser O; Kessler T; Burgdorf C; Templin C; Pellegrini C; Schneider S; Kasel AM; Kastrati A; Schunkert H; Hengstenberg C
    Rev Esp Cardiol (Engl Ed); 2016 Feb; 69(2):141-8. PubMed ID: 26542175
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.
    Gonska B; Seeger J; Keßler M; von Keil A; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2017 Aug; 106(8):590-597. PubMed ID: 28283746
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.
    Maeno Y; Abramowitz Y; Kawamori H; Kazuno Y; Kubo S; Takahashi N; Mangat G; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Friedman J; Berman D; Makkar RR; Jilaihawi H
    JACC Cardiovasc Imaging; 2017 Oct; 10(10 Pt A):1139-1147. PubMed ID: 28412434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Association between implantation depth assessed by computed tomography and new-onset conduction disturbances after transcatheter aortic valve implantation.
    Almeida JG; Ferreira SM; Fonseca P; Dias T; Guerreiro C; Barbosa AR; Teixeira P; Carvalho M; Ferreira W; Ferreira ND; Oliveira M; Gonçalves H; Braga P; Ribeiro J; Primo J; Ribeiro VG
    J Cardiovasc Comput Tomogr; 2017; 11(5):332-337. PubMed ID: 28844528
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation.
    van der Boon RM; Houthuizen P; Urena M; Poels TT; van Mieghem NM; Brueren GR; Altintas S; Nuis RJ; Serruys PW; van Garsse LA; van Domburg RT; Cabau JR; de Jaegere PP; Prinzen FW
    Catheter Cardiovasc Interv; 2015 Apr; 85(5):E144-52. PubMed ID: 25504891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictors of Need for Permanent Pacemaker Implantation and Conduction Abnormalities With a Novel Self-expanding Transcatheter Heart Valve.
    Pellegrini C; Husser O; Kim WK; Holzamer A; Walther T; Rheude T; Mayr NP; Trenkwalder T; Joner M; Michel J; Chaustre F; Kastrati A; Schunkert H; Burgdorf C; Hilker M; Möllmann H; Hengstenberg C
    Rev Esp Cardiol (Engl Ed); 2019 Feb; 72(2):145-153. PubMed ID: 29551701
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients.
    Xiong TY; Liao YB; Li YJ; Zhao ZG; Wei X; Tsauo JY; Xu YN; Feng Y; Chen M
    J Interv Cardiol; 2018 Dec; 31(6):878-884. PubMed ID: 30079561
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations.
    Husser O; Pellegrini C; Kim WK; Holzamer A; Pilgrim T; Toggweiler S; Schäfer U; Blumenstein J; Deuschl F; Rheude T; Joner M; Hilker M; Hengstenberg C; Möllmann H
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1781-1793. PubMed ID: 31537278
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.
    Urena M; Mok M; Serra V; Dumont E; Nombela-Franco L; DeLarochellière R; Doyle D; Igual A; Larose E; Amat-Santos I; Côté M; Cuéllar H; Pibarot P; de Jaegere P; Philippon F; Garcia del Blanco B; Rodés-Cabau J
    J Am Coll Cardiol; 2012 Oct; 60(18):1743-52. PubMed ID: 23040577
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique.
    Iacovelli F; Giugliano G; Gerardi D; Salemme L; Cioppa A; Pucciarelli A; Popusoi G; Loizzi F; Schettino G; Favale S; Solimene F; Esposito G; Tesorio T; Stabile E
    Heart Vessels; 2022 Feb; 37(2):337-346. PubMed ID: 34524496
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Permanent Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement.
    Romano MA; Koeckert M; Mumtaz MA; Slachman FN; Patel HJ; Chitwood WR; Barnhart GR; Grossi EA;
    Ann Thorac Surg; 2018 Sep; 106(3):685-690. PubMed ID: 29705366
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.
    Droppa M; Rudolph TK; Baan J; Nielsen NE; Baumgartner H; Vendrik J; Froehlich M; Borst O; Wöhrle J; Gawaz M; Potratz P; Hack LP; Mauri V; Baranowski J; Bramlage P; Kurucova J; Thoenes M; Rottbauer W; Geisler T
    Heart Vessels; 2020 Dec; 35(12):1735-1745. PubMed ID: 32591894
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multicenter Evaluation of Prosthesis Oversizing of the SAPIEN 3 Transcatheter Heart Valve. Impact on Device Failure and New Pacemaker Implantations.
    Pellegrini C; Kim WK; Holzamer A; Walther T; Mayr NP; Michel J; Rheude T; Nuñez J; Kasel AM; Trenkwalder T; Kaess BM; Joner M; Kastrati A; Schunkert H; Hilker M; Möllmann H; Hengstenberg C; Husser O
    Rev Esp Cardiol (Engl Ed); 2019 Aug; 72(8):641-648. PubMed ID: 30017841
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry.
    Rudolph T; Droppa M; Baan J; Nielsen NE; Baranowski J; Hachaturyan V; Kurucova J; Hack L; Bramlage P; Geisler T
    Open Heart; 2023 Feb; 10(1):. PubMed ID: 36750275
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.