These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 26847188)

  • 1. Assessment of diffusion parameters of new passive samplers using optical chemical sensor for on-site measuring formaldehyde in indoor air: experimental and numerical studies.
    Vignau-Laulhere J; Mocho P; Plaisance H; Raulin K; Desauziers V
    Anal Bioanal Chem; 2016 Mar; 408(8):2147-57. PubMed ID: 26847188
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Formaldehyde passive sampler using an optical chemical sensor: how to limit the humidity interference.
    Vignau-Laulhere J; Mocho P; Plaisance H; Raulin-Woznica K; Tran-Thi TH; Desauziers V
    Anal Bioanal Chem; 2017 Oct; 409(26):6245-6252. PubMed ID: 28808738
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.
    Araki A; Eitaki Y; Kawai T; Kanazawa A; Takeda M; Kishi R
    Indoor Air; 2009 Oct; 19(5):421-32. PubMed ID: 19656233
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes.
    Batterman S; Metts T; Kalliokoski P
    J Environ Monit; 2002 Dec; 4(6):870-8. PubMed ID: 12509039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monitoring of parts-per-billion levels of formaldehyde using a diffusive sampler.
    Levin JO; Lindahl R; Andersson K
    JAPCA; 1989 Jan; 39(1):44-7. PubMed ID: 2709076
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inverse Problem Optimization Method to Design Passive Samplers for Volatile Organic Compounds: Principle and Application.
    Cao J; Du Z; Mo J; Li X; Xu Q; Zhang Y
    Environ Sci Technol; 2016 Dec; 50(24):13477-13485. PubMed ID: 27993075
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of diffusive mini-samplers for aldehyde and VOC and its feasibility for measuring the exposure levels of elementary school children.
    Araki A; Tsuboi T; Kawai T; Bamai YA; Takeda T; Yoshioka E; Kishi R
    J Environ Monit; 2012 Feb; 14(2):368-74. PubMed ID: 21986583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a passive air sampler for measuring indoor formaldehyde.
    Kim ST; Yim B; Jeong J
    Anal Sci; 2007 Apr; 23(4):497-500. PubMed ID: 17420560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Field evaluation of thermal and chemical desorption BTEX radial diffusive sampler radiello compared with active (pumped) samplers for ambient air measurements.
    Cocheo C; Boaretto C; Pagani D; Quaglio F; Sacco P; Zaratin L; Cottica D
    J Environ Monit; 2009 Feb; 11(2):297-306. PubMed ID: 19212585
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.
    Witschger O; Grinshpun SA; Fauvel S; Basso G
    Ann Occup Hyg; 2004 Jun; 48(4):351-68. PubMed ID: 15191944
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Testing flow-through air samplers for use in near-field vapour drift studies by measuring pyrimethanil in air after spraying.
    Geoghegan TS; Hageman KJ; Hewitt AJ
    Environ Sci Process Impacts; 2014 Mar; 16(3):422-32. PubMed ID: 24365971
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new approach for diffusive sampling based on SPME for occupational exposure assessment.
    Marín P; Periago JF; Prado C
    J Occup Environ Hyg; 2013; 10(3):132-42. PubMed ID: 23356408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Badge-type diffusive sampler using 3-methyl-2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air.
    Yim B; Jung E
    Anal Sci; 2006 Jul; 22(7):993-7. PubMed ID: 16837752
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Formaldehyde emission behavior of building materials: on-site measurements and modeling approach to predict indoor air pollution.
    Bourdin D; Mocho P; Desauziers V; Plaisance H
    J Hazard Mater; 2014 Sep; 280():164-73. PubMed ID: 25151239
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
    Cohen BS; Heikkinen MS; Hazi Y; Gao H; Peters P; Lippmann M
    Res Rep Health Eff Inst; 2004 Sep; (121):1-35; discussion 37-46. PubMed ID: 15553489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a new passive sampler based on diffusive milligel beads for copper analysis in water.
    Perez M; Reynaud S; Lespes G; Potin-Gautier M; Mignard E; Chéry P; Schaumlöffel D; Grassl B
    Anal Chim Acta; 2015 Aug; 890():117-23. PubMed ID: 26347173
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of reference chemicals to determine passive uptake rates of common indoor air VOCs by collocation deployment of active and passive samplers.
    Xian Q; Feng YL; Chan CC; Zhu J
    J Environ Monit; 2011 Sep; 13(9):2527-34. PubMed ID: 21773627
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel passive water sampler for in situ sampling of antibiotics.
    Chen CE; Zhang H; Jones KC
    J Environ Monit; 2012 May; 14(6):1523-30. PubMed ID: 22538362
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of sampler configuration on the uptake kinetics of a passive air sampler.
    Zhang X; Wong C; Lei YD; Wania F
    Environ Sci Technol; 2012 Jan; 46(1):397-403. PubMed ID: 22103289
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a miniaturized diffusive sampler for true breathing-zone sampling and thermal desorption gas chromatographic analysis.
    Lindahl R; Levin JO; Sundgren M
    J Environ Monit; 2009 Jul; 11(7):1340-4. PubMed ID: 20449222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.