These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
62 related articles for article (PubMed ID: 26851886)
1. Icare vs Tono-Pen in the ED. LoVecchio F; Salveson P; Mulrow M; Malashock H Am J Emerg Med; 2016 Mar; 34(3):670-3. PubMed ID: 26851886 [No Abstract] [Full Text] [Related]
2. Intraocular pressure in children: the effect of body position as assessed by Icare and Tono-Pen tonometers. Dosunmu EO; Marcus I; Tung I; Thiamthat W; Freedman SF Am J Ophthalmol; 2014 Dec; 158(6):1348-1352.e1. PubMed ID: 25217858 [TBL] [Abstract][Full Text] [Related]
3. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions. Lee TE; Yoo C; Hwang JY; Lin S; Kim YY Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991 [TBL] [Abstract][Full Text] [Related]
4. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model. Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. García-Resúa C; González-Meijome JM; Gilino J; Yebra-Pimentel E Optom Vis Sci; 2006 Feb; 83(2):102-7. PubMed ID: 16501412 [TBL] [Abstract][Full Text] [Related]
6. Agreement and reproducibility of Tono-Pen XL tip covered with ocufilm and fingertip of surgical glove in intra-ocular pressure measurement. Sayawat N; Duangnumsawang D J Med Assoc Thai; 2012 Apr; 95 Suppl 4():S102-6. PubMed ID: 22696861 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of the ICare rebound tonometer as a home intraocular pressure monitoring device. Asrani S; Chatterjee A; Wallace DK; Santiago-Turla C; Stinnett S J Glaucoma; 2011 Feb; 20(2):74-9. PubMed ID: 20436362 [TBL] [Abstract][Full Text] [Related]
8. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology. von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625 [TBL] [Abstract][Full Text] [Related]
9. Icare ONE rebound versus Goldmann applanation tonometry in children with known or suspected glaucoma. Gandhi NG; Prakalapakorn SG; El-Dairi MA; Jones SK; Freedman SF Am J Ophthalmol; 2012 Nov; 154(5):843-849.e1. PubMed ID: 22840485 [TBL] [Abstract][Full Text] [Related]
10. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes]. Deuter CM; Schlote T; Hahn GA; Bende T; Derse M Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041 [TBL] [Abstract][Full Text] [Related]
11. [Clinical and experimental evaluation of the so-called Tono-Pen tonometer]. Draeger J; Rumberger E; Wirt H Klin Monbl Augenheilkd; 1989 Sep; 195(3):196-202. PubMed ID: 2811184 [TBL] [Abstract][Full Text] [Related]
13. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*. van der Jagt LH; Jansonius NM Ophthalmic Physiol Opt; 2005 Sep; 25(5):429-35. PubMed ID: 16101949 [TBL] [Abstract][Full Text] [Related]
14. [Comparative study of two portable tonometers: Tono-Pen XL and Perkins]. Andrada Márquez MT; Fesser Oroz I; Antón López A Arch Soc Esp Oftalmol; 2003 Apr; 78(4):189-96. PubMed ID: 12743842 [TBL] [Abstract][Full Text] [Related]
15. [Clinical evaluation of the ICare tonometer in measuring intraocular pressure]. Krzyzanowska-Berkowska P; Asejczyk-Widlicka M Klin Oczna; 2010; 112(7-9):217-20. PubMed ID: 21121124 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Perkins, Tono-Pen and Schiøtz tonometers in paediatric patients under general anaesthesia. Gharaei H; Kargozar A; Raygan F; Daneshvar R East Mediterr Health J; 2008; 14(6):1365-71. PubMed ID: 19161112 [TBL] [Abstract][Full Text] [Related]
17. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma. Carrim ZI; Lavy TE Ophthalmic Physiol Opt; 2009 Nov; 29(6):648-51. PubMed ID: 19821927 [TBL] [Abstract][Full Text] [Related]
18. Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure. Sakamoto M; Kanamori A; Fujihara M; Yamada Y; Nakamura M; Negi A Acta Ophthalmol; 2014 May; 92(3):243-8. PubMed ID: 23586927 [TBL] [Abstract][Full Text] [Related]
19. Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting. Kim KN; Jeoung JW; Park KH; Yang MK; Kim DM Acta Ophthalmol; 2013 Aug; 91(5):e392-6. PubMed ID: 23521889 [TBL] [Abstract][Full Text] [Related]
20. Clinical Use of iCare Home Quérat L; Chen E Acta Ophthalmol; 2020 Feb; 98(1):e131-e132. PubMed ID: 31430031 [No Abstract] [Full Text] [Related] [Next] [New Search]