BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

270 related articles for article (PubMed ID: 26854572)

  • 1. Modelling the temperature evolution of bone under high intensity focused ultrasound.
    ten Eikelder HM; Bošnački D; Elevelt A; Donato K; Di Tullio A; Breuer BJ; van Wijk JH; van Dijk EV; Modena D; Yeo SY; Grüll H
    Phys Med Biol; 2016 Feb; 61(4):1810-28. PubMed ID: 26854572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue.
    Hudson TJ; Looi T; Pichardo S; Amaral J; Temple M; Drake JM; Waspe AC
    Med Phys; 2018 Feb; 45(2):506-519. PubMed ID: 29193144
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling the interference between shear and longitudinal waves under high intensity focused ultrasound propagation in bone.
    Modena D; Baragona M; Bošnački D; Breuer BJT; Elevelt A; Maessen RTH; Hilbers PAJ; Ten Eikelder HMM
    Phys Med Biol; 2018 Dec; 63(23):235024. PubMed ID: 30511661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver.
    Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q
    Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-gradient echo MR thermometry for monitoring of the near-field area during MR-guided high intensity focused ultrasound heating.
    Lam MK; de Greef M; Bouwman JG; Moonen CT; Viergever MA; Bartels LW
    Phys Med Biol; 2015 Oct; 60(19):7729-45. PubMed ID: 26394264
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tissue-mimicking thermochromic phantom for characterization of HIFU devices and applications.
    Eranki A; Mikhail AS; Negussie AH; Katti PS; Wood BJ; Partanen A
    Int J Hyperthermia; 2019; 36(1):518-529. PubMed ID: 31046513
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.
    Partanen A; Tillander M; Yarmolenko PS; Wood BJ; Dreher MR; Kohler MO
    Med Phys; 2013 Jan; 40(1):013301. PubMed ID: 23298120
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of near-field heating during volumetric MR-HIFU ablation.
    Mougenot C; Köhler MO; Enholm J; Quesson B; Moonen C
    Med Phys; 2011 Jan; 38(1):272-82. PubMed ID: 21361196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Temperature-dependent MR signals in cortical bone: potential for monitoring temperature changes during high-intensity focused ultrasound treatment in bone.
    Ramsay E; Mougenot C; Kazem M; Laetsch TW; Chopra R
    Magn Reson Med; 2015 Oct; 74(4):1095-102. PubMed ID: 25310966
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
    Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT
    NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mild hyperthermia by MR-guided focused ultrasound in an ex vivo model of osteolytic bone tumour: optimization of the spatio-temporal control of the delivered temperature.
    Guillemin PC; Gui L; Lorton O; Zilli T; Crowe LA; Desgranges S; Montet X; Terraz S; Miralbell R; Salomir R; Boudabbous S
    J Transl Med; 2019 Oct; 17(1):350. PubMed ID: 31651311
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A clinically feasible treatment protocol for magnetic resonance-guided high-intensity focused ultrasound ablation in the liver.
    Wijlemans JW; de Greef M; Schubert G; Bartels LW; Moonen CT; van den Bosch MA; Ries M
    Invest Radiol; 2015 Jan; 50(1):24-31. PubMed ID: 25198833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correction of proton resonance frequency shift MR-thermometry errors caused by heat-induced magnetic susceptibility changes during high intensity focused ultrasound ablations in tissues containing fat.
    Baron P; Deckers R; de Greef M; Merckel LG; Bakker CJ; Bouwman JG; Bleys RL; van den Bosch MA; Bartels LW
    Magn Reson Med; 2014 Dec; 72(6):1580-9. PubMed ID: 24347129
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A nonparametric temperature controller with nonlinear negative reaction for multi-point rapid MR-guided HIFU ablation.
    Petrusca L; Auboiroux V; Goget T; Viallon M; Muller A; Gross P; Becker CD; Salomir R
    IEEE Trans Med Imaging; 2014 Jun; 33(6):1324-37. PubMed ID: 24893259
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.
    Celicanin Z; Manasseh G; Petrusca L; Scheffler K; Auboiroux V; Crowe LA; Hyacinthe JN; Natsuaki Y; Santini F; Becker CD; Terraz S; Bieri O; Salomir R
    Magn Reson Med; 2018 May; 79(5):2511-2523. PubMed ID: 28944490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Increasing the HIFU ablation rate through an MRI-guided sonication strategy using shock waves: feasibility in the in vivo porcine liver.
    Ramaekers P; de Greef M; van Breugel JM; Moonen CT; Ries M
    Phys Med Biol; 2016 Feb; 61(3):1057-77. PubMed ID: 26757987
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monitoring MR-guided high intensity focused ultrasound therapy using transient supersonic shear wave MR-elastography.
    Ishak O; Breton E; Choquet K; Josset A; Cabras P; Vappou J
    Phys Med Biol; 2023 Jan; 68(3):. PubMed ID: 36595333
    [No Abstract]   [Full Text] [Related]  

  • 19. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation.
    Chu W; Staruch RM; Pichardo S; Tillander M; Köhler MO; Huang Y; Ylihautala M; McGuffin M; Czarnota G; Hynynen K
    Int J Radiat Oncol Biol Phys; 2016 Jul; 95(4):1259-67. PubMed ID: 27209510
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Robust adaptive extended Kalman filtering for real time MR-thermometry guided HIFU interventions.
    Roujol S; de Senneville BD; Hey S; Moonen C; Ries M
    IEEE Trans Med Imaging; 2012 Mar; 31(3):533-42. PubMed ID: 21997254
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.