270 related articles for article (PubMed ID: 26854572)
21. Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation.
Zhou Y
Ultrasound Q; 2017 Dec; 33(4):253-260. PubMed ID: 28549003
[TBL] [Abstract][Full Text] [Related]
22. Improving thermal dose accuracy in magnetic resonance-guided focused ultrasound surgery: Long-term thermometry using a prior baseline as a reference.
Bitton RR; Webb TD; Pauly KB; Ghanouni P
J Magn Reson Imaging; 2016 Jan; 43(1):181-9. PubMed ID: 26119129
[TBL] [Abstract][Full Text] [Related]
23. Performance analysis of a dedicated breast MR-HIFU system for tumor ablation in breast cancer patients.
Deckers R; Merckel LG; Denis de Senneville B; Schubert G; Köhler M; Knuttel FM; Mali WP; Moonen CT; van den Bosch MA; Bartels LW
Phys Med Biol; 2015 Jul; 60(14):5527-42. PubMed ID: 26133986
[TBL] [Abstract][Full Text] [Related]
24. Interleaved water and fat MR thermometry for monitoring high intensity focused ultrasound ablation of bone lesions.
Lena B; Bartels LW; Ferrer CJ; Moonen CTW; Viergever MA; Bos C
Magn Reson Med; 2021 Nov; 86(5):2647-2655. PubMed ID: 34061390
[TBL] [Abstract][Full Text] [Related]
25. Prolonged heating in nontargeted tissue during MR-guided focused ultrasound of bone tumors.
Bitton RR; Webb TD; Pauly KB; Ghanouni P
J Magn Reson Imaging; 2019 Nov; 50(5):1526-1533. PubMed ID: 30950554
[TBL] [Abstract][Full Text] [Related]
26. Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo.
Auboiroux V; Petrusca L; Viallon M; Goget T; Becker CD; Salomir R
Phys Med Biol; 2012 May; 57(10):N159-71. PubMed ID: 22517112
[TBL] [Abstract][Full Text] [Related]
27. MR imaging-guided focused ultrasound for treatment of bone metastasis.
Napoli A; Anzidei M; Marincola BC; Brachetti G; Noce V; Boni F; Bertaccini L; Passariello R; Catalano C
Radiographics; 2013 Oct; 33(6):1555-68. PubMed ID: 24108551
[TBL] [Abstract][Full Text] [Related]
28. Bone metastasis treatment using magnetic resonance-guided high intensity focused ultrasound.
Yeo SY; Elevelt A; Donato K; van Rietbergen B; Ter Hoeve ND; van Diest PJ; Grüll H
Bone; 2015 Dec; 81():513-523. PubMed ID: 26325304
[TBL] [Abstract][Full Text] [Related]
29. A standard test phantom for the performance assessment of magnetic resonance guided high intensity focused ultrasound (MRgHIFU) thermal therapy devices.
Ambrogio S; Baêsso RM; Bosio F; Fedele F; Ramnarine KV; Zeqiri B; Miloro P
Int J Hyperthermia; 2022; 39(1):57-68. PubMed ID: 34936852
[No Abstract] [Full Text] [Related]
30. The effects of Magnetic Resonance Imaging-guided High-Intensity Focused Ultrasound ablation on human cadaver breast tissue.
Merckel LG; Deckers R; Baron P; Bleys RL; van Diest PJ; Moonen CT; Mali WP; van den Bosch MA; Bartels LW
Eur J Pharmacol; 2013 Oct; 717(1-3):21-30. PubMed ID: 23583321
[TBL] [Abstract][Full Text] [Related]
31. A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.
Chen Q; Li Y; Jiang R; Zou C; Tie C; Wen J; Yang X; Zhang X; Liu X; Zheng H
Magn Reson Imaging; 2020 Jan; 65():37-44. PubMed ID: 31655140
[TBL] [Abstract][Full Text] [Related]
32. Advances in MR image-guided high-intensity focused ultrasound therapy.
Kim YS
Int J Hyperthermia; 2015 May; 31(3):225-32. PubMed ID: 25373687
[TBL] [Abstract][Full Text] [Related]
33. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model.
Huisman M; Staruch RM; Ladouceur-Wodzak M; van den Bosch MA; Burns DK; Chhabra A; Chopra R
PLoS One; 2015; 10(12):e0144742. PubMed ID: 26659073
[TBL] [Abstract][Full Text] [Related]
34. Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging.
Peng Y; Zou C; Qiao Y; Tie C; Wan Q; Jiang R; Cheng C; Liang D; Zheng H; Li F; Liu X
MAGMA; 2018 Dec; 31(6):771-779. PubMed ID: 29948236
[TBL] [Abstract][Full Text] [Related]
35. Cavitation-enhanced MR-guided focused ultrasound ablation of rabbit tumors in vivo using phase shift nanoemulsions.
Kopechek JA; Park EJ; Zhang YZ; Vykhodtseva NI; McDannold NJ; Porter TM
Phys Med Biol; 2014 Jul; 59(13):3465-81. PubMed ID: 24899634
[TBL] [Abstract][Full Text] [Related]
36. Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks.
de Greef M; Schubert G; Wijlemans JW; Koskela J; Bartels LW; Moonen CT; Ries M
Med Phys; 2015 Aug; 42(8):4685-97. PubMed ID: 26233196
[TBL] [Abstract][Full Text] [Related]
37. Pre-clinical study of in vivo magnetic resonance-guided bubble-enhanced heating in pig liver.
Elbes D; Denost Q; Laurent C; Trillaud H; Rullier A; Quesson B
Ultrasound Med Biol; 2013 Aug; 39(8):1388-97. PubMed ID: 23562012
[TBL] [Abstract][Full Text] [Related]
38. High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control.
Tillander M; Hokland S; Koskela J; Dam H; Andersen NP; Pedersen M; Tanderup K; Ylihautala M; Köhler M
Med Phys; 2016 Mar; 43(3):1539-49. PubMed ID: 26936737
[TBL] [Abstract][Full Text] [Related]
39. Thermometry during MR-guided focused ultrasound in a preclinical model based on Thiel embalmed tissue.
Karakitsios I; Bobeica M; Saliev T; Rube M; Melzer A
Minim Invasive Ther Allied Technol; 2014 Mar; 23(2):120-6. PubMed ID: 24079349
[TBL] [Abstract][Full Text] [Related]
40. Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model.
Wijlemans JW; Deckers R; van den Bosch MA; Seinstra BA; van Stralen M; van Diest PJ; Moonen CT; Bartels LW
Invest Radiol; 2013 Jun; 48(6):381-6. PubMed ID: 23399810
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]