These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 26866276)

  • 41. In-situ integrity control of frozen-hydrated, vitreous lamellas prepared by the cryo-focused ion beam-scanning electron microscope.
    de Winter DA; Mesman RJ; Hayles MF; Schneijdenberg CT; Mathisen C; Post JA
    J Struct Biol; 2013 Jul; 183(1):11-8. PubMed ID: 23742839
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Depth Resolution Dependence on Sample Thickness and Incident Energy in On-Axis Transmission Kikuchi Diffraction in Scanning Electron Microscope (SEM).
    Brodu E; Bouzy E
    Microsc Microanal; 2017 Dec; 23(6):1096-1106. PubMed ID: 29282164
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Replica extraction method on nanostructured gold coatings and orientation determination combining SEM and TEM techniques.
    Bocker C; Kracker M; Rüssel C
    Microsc Microanal; 2014 Dec; 20(6):1654-61. PubMed ID: 25313465
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Identifying threading dislocations in GaN films and substrates by electron channelling.
    Kamaladasa RJ; Liu F; Porter LM; Davis RF; Koleske DD; Mulholland G; Jones KA; Picard YN
    J Microsc; 2011 Dec; 244(3):311-9. PubMed ID: 21883210
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Three-dimensional orientation mapping in the transmission electron microscope.
    Liu HH; Schmidt S; Poulsen HF; Godfrey A; Liu ZQ; Sharon JA; Huang X
    Science; 2011 May; 332(6031):833-4. PubMed ID: 21566190
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Orientation mapping of semicrystalline polymers using scanning electron nanobeam diffraction.
    Panova O; Chen XC; Bustillo KC; Ophus C; Bhatt MP; Balsara N; Minor AM
    Micron; 2016 Sep; 88():30-6. PubMed ID: 27323282
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A transmission electron microscope (TEM) calibration standard sample for all magnification, camera constant, and image/diffraction pattern rotation calibrations.
    McCaffrey JP; Baribeau JM
    Microsc Res Tech; 1995 Dec; 32(5):449-54. PubMed ID: 8563043
    [TBL] [Abstract][Full Text] [Related]  

  • 48. TEM illumination settings study for optimum spatial resolution and indexing reliability in crystal orientation mappings.
    Valery A; Pofelski A; Clément L; Lorut F; Rauch EF
    Micron; 2017 Jan; 92():43-50. PubMed ID: 27866100
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Three-dimensional grain mapping by x-ray diffraction contrast tomography and the use of Friedel pairs in diffraction data analysis.
    Ludwig W; Reischig P; King A; Herbig M; Lauridsen EM; Johnson G; Marrow TJ; Buffière JY
    Rev Sci Instrum; 2009 Mar; 80(3):033905. PubMed ID: 19334932
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Meretrix lusoria--a natural biocomposite material: in situ analysis of hierarchical fabrication and micro-hardness.
    Zhu Z; Tong H; Ren Y; Hu J
    Micron; 2006; 37(1):35-40. PubMed ID: 16169741
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Precipitate crystal structure determination in melt spun Mg-1.5wt%Ca-6wt%Zn alloy.
    Jardim PM; Solórzano G; Sande JB
    Microsc Microanal; 2002 Dec; 8(6):487-96. PubMed ID: 12533209
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Scanning electron microscopy imaging of dislocations in bulk materials, using electron channeling contrast.
    Crimp MA
    Microsc Res Tech; 2006 May; 69(5):374-81. PubMed ID: 16646010
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Grain boundary atomic structures and light-element visualization in ceramics: combination of Cs-corrected scanning transmission electron microscopy and first-principles calculations.
    Ikuhara Y
    J Electron Microsc (Tokyo); 2011; 60 Suppl 1():S173-88. PubMed ID: 21844588
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Quantitative misorientation characteristics of interphase boundaries in composites.
    Sztwiertnia K; Faryna M; Sawina G
    J Microsc; 2006 Oct; 224(Pt 1):4-7. PubMed ID: 17100892
    [TBL] [Abstract][Full Text] [Related]  

  • 55. EBSD image quality mapping.
    Wright SI; Nowell MM
    Microsc Microanal; 2006 Feb; 12(1):72-84. PubMed ID: 17481343
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Advance in orientation microscopy: quantitative analysis of nanocrystalline structures.
    Seyring M; Song X; Rettenmayr M
    ACS Nano; 2011 Apr; 5(4):2580-6. PubMed ID: 21375327
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Mapping the magnetic and crystal structure in cobalt nanowires.
    Cantu-Valle J; Betancourt I; Sanchez JE; Ruiz-Zepeda F; Maqableh MM; Mendoza-Santoyo F; Stadler BJ; Ponce A
    J Appl Phys; 2015 Jul; 118(2):024302. PubMed ID: 26221057
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A tilting procedure to enhance compositional contrast and reduce residual diffraction contrast in energy-filtered TEM imaging of planar interfaces.
    Moore KT; Stach EA; Howe JM; Elbert DC; Veblen DR
    Micron; 2002; 33(1):39-51. PubMed ID: 11473813
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Flat ion milling: a powerful tool for preparation of cross-sections of lead-silver alloys.
    Brodusch N; Boisvert S; Gauvin R
    Microscopy (Oxf); 2013 Jun; 62(3):411-8. PubMed ID: 23160362
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Three-dimensional EBSD study on the relationship between triple junctions and columnar grains in electrodeposited Co-Ni films.
    Bastos A; Zaefferer S; Raabe D
    J Microsc; 2008 Jun; 230(Pt 3):487-98. PubMed ID: 18503675
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.