401 related articles for article (PubMed ID: 26866711)
1. Continuous End-Tidal Carbon Dioxide Monitoring during Resuscitation of Asphyxiated Term Lambs.
Chandrasekharan PK; Rawat M; Nair J; Gugino SF; Koenigsknecht C; Swartz DD; Vali P; Mathew B; Lakshminrusimha S
Neonatology; 2016; 109(4):265-73. PubMed ID: 26866711
[TBL] [Abstract][Full Text] [Related]
2. Mainstream end-tidal carbon dioxide monitoring in ventilated neonates.
Bhat YR; Abhishek N
Singapore Med J; 2008 Mar; 49(3):199-203. PubMed ID: 18363000
[TBL] [Abstract][Full Text] [Related]
3. End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates.
Tingay DG; Mun KS; Perkins EJ
Arch Dis Child Fetal Neonatal Ed; 2013 Mar; 98(2):F161-4. PubMed ID: 22887048
[TBL] [Abstract][Full Text] [Related]
4. Neonatal resuscitation adhering to oxygen saturation guidelines in asphyxiated lambs with meconium aspiration.
Rawat M; Chandrasekharan PK; Swartz DD; Mathew B; Nair J; Gugino SF; Koenigsknecht C; Vali P; Lakshminrusimha S
Pediatr Res; 2016 Apr; 79(4):583-8. PubMed ID: 26672734
[TBL] [Abstract][Full Text] [Related]
5. Noninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns.
Belenkiy S; Ivey KM; Batchinsky AI; Langer T; Necsoiu C; Baker W; Salinas J; Cancio LC
Shock; 2013 Jun; 39(6):495-500. PubMed ID: 23572088
[TBL] [Abstract][Full Text] [Related]
6. Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide.
Tobias JD; Meyer DJ
Anesth Analg; 1997 Jul; 85(1):55-8. PubMed ID: 9212122
[TBL] [Abstract][Full Text] [Related]
7. Comparison of ventilator-integrated end-tidal CO2 and transcutaneous CO2 monitoring in home-ventilated neuromuscular patients.
Orlikowski D; Prigent H; Ambrosi X; Vaugier I; Pottier S; Annane D; Lofaso F; Ogna A
Respir Med; 2016 Aug; 117():7-13. PubMed ID: 27492508
[TBL] [Abstract][Full Text] [Related]
8. Arterial to end-tidal carbon dioxide difference in children undergoing mechanical ventilation of the lungs during general anaesthesia.
Onodi C; Bühler PK; Thomas J; Schmitz A; Weiss M
Anaesthesia; 2017 Nov; 72(11):1357-1364. PubMed ID: 28695980
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of end-tidal CO2 capnometers in post-cardiac surgery patients during controlled mechanical ventilation.
Heines SJ; Strauch U; Roekaerts PM; Winkens B; Bergmans DC
J Emerg Med; 2013 Jul; 45(1):130-5. PubMed ID: 23375221
[TBL] [Abstract][Full Text] [Related]
10. A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2.
Kugelman A; Zeiger-Aginsky D; Bader D; Shoris I; Riskin A
Pediatrics; 2008 Dec; 122(6):e1219-24. PubMed ID: 19029196
[TBL] [Abstract][Full Text] [Related]
11. The utility of early end-tidal capnography in monitoring ventilation status after severe injury.
Warner KJ; Cuschieri J; Garland B; Carlbom D; Baker D; Copass MK; Jurkovich GJ; Bulger EM
J Trauma; 2009 Jan; 66(1):26-31. PubMed ID: 19131802
[TBL] [Abstract][Full Text] [Related]
12. Comparison of a sidestream capnograph and a mainstream capnograph in mechanically ventilated dogs.
Teixeira Neto FJ; Carregaro AB; Mannarino R; Cruz ML; Luna SP
J Am Vet Med Assoc; 2002 Dec; 221(11):1582-5. PubMed ID: 12479328
[TBL] [Abstract][Full Text] [Related]
13. Detection of carbon dioxide thresholds using low-flow sidestream capnography in ventilated preterm infants.
Lopez E; Grabar S; Barbier A; Krauss B; Jarreau PH; Moriette G
Intensive Care Med; 2009 Nov; 35(11):1942-9. PubMed ID: 19760396
[TBL] [Abstract][Full Text] [Related]
14. Validity of sidestream endtidal carbon dioxide measurement in critically ill, mechanically ventilated children.
van der Heijden HH; Truin GJ; Verhaeg J; van der Pol P; Lemson J
Paediatr Anaesth; 2016 Mar; 26(3):294-9. PubMed ID: 26714621
[TBL] [Abstract][Full Text] [Related]
15. Monitoring persistent pulmonary hypertension of the newborn using the arterial to end tidal carbon dioxide gradient.
Williams EE; Bednarczuk N; Nanjundappa M; Greenough A; Dassios T
J Clin Monit Comput; 2024 Apr; 38(2):463-467. PubMed ID: 38150123
[TBL] [Abstract][Full Text] [Related]
16. Continuous capnography monitoring during resuscitation in a transitional large mammalian model of asphyxial cardiac arrest.
Chandrasekharan P; Vali P; Rawat M; Mathew B; Gugino SF; Koenigsknecht C; Helman J; Nair J; Berkelhamer S; Lakshminrusimha S
Pediatr Res; 2017 Jun; 81(6):898-904. PubMed ID: 28157836
[TBL] [Abstract][Full Text] [Related]
17. Correlation of arterial and end-tidal carbon dioxide in spontaneously breathing patients during ambulatory gynecologic laparoscopy.
Cheng KI; Tang CS; Tsai EM; Wu CH; Lee JN
J Formos Med Assoc; 1999 Dec; 98(12):814-9. PubMed ID: 10634020
[TBL] [Abstract][Full Text] [Related]
18. End tidal carbon dioxide monitoring--its reliability in neonates.
Nangia S; Saili A; Dutta AK
Indian J Pediatr; 1997; 64(3):389-94. PubMed ID: 10771861
[TBL] [Abstract][Full Text] [Related]
19. Assessment of sidestream end-tidal capnography in ventilated infants on the neonatal unit.
Williams E; Dassios T; Greenough A
Pediatr Pulmonol; 2020 Jun; 55(6):1468-1473. PubMed ID: 32187888
[TBL] [Abstract][Full Text] [Related]
20. [Use of microstream capnography and alveolar recruitment during off-pump coronary artery bypass grafting].
Suborov EV; Postnikova EA; Kapinos AA; Kuz'kov VV; Smetkin AA; Kirov MIu
Anesteziol Reanimatol; 2009; (4):17-22. PubMed ID: 19824412
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]