BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 26872908)

  • 1. Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls.
    Camargo GC; Rothstein T; Junqueira FP; Fernandes E; Greiser A; Strecker R; Pessoa V; Lima RS; Gottlieb I
    Int J Hematol; 2016 May; 103(5):530-6. PubMed ID: 26872908
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload.
    Sado DM; Maestrini V; Piechnik SK; Banypersad SM; White SK; Flett AS; Robson MD; Neubauer S; Ariti C; Arai A; Kellman P; Yamamura J; Schoennagel BP; Shah F; Davis B; Trompeter S; Walker M; Porter J; Moon JC
    J Magn Reson Imaging; 2015 Jun; 41(6):1505-11. PubMed ID: 25104503
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Free-breathing myocardial T2* mapping using GRE-EPI and automatic non-rigid motion correction.
    Jin N; da Silveira JS; Jolly MP; Firmin DN; Mathew G; Lamba N; Subramanian S; Pennell DJ; Raman SV; Simonetti OP
    J Cardiovasc Magn Reson; 2015 Dec; 17():113. PubMed ID: 26699850
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of cardiac iron overload with native magnetic resonance T1 and T2 mapping in patients with thalassemia.
    Krittayaphong R; Zhang S; Saiviroonporn P; Viprakasit V; Tanapibunpon P; Komoltri C; Wangworatrakul W
    Int J Cardiol; 2017 Dec; 248():421-426. PubMed ID: 28688717
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Myocardial T2 quantitation in patients with iron overload at 3 Tesla.
    Guo H; Au WY; Cheung JS; Kim D; Jensen JH; Khong PL; Chan Q; Chan KC; Tosti C; Tang H; Brown TR; Lam WW; Ha SY; Brittenham GM; Wu EX
    J Magn Reson Imaging; 2009 Aug; 30(2):394-400. PubMed ID: 19629983
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Contrast-optimized composite image derived from multigradient echo cardiac magnetic resonance imaging improves reproducibility of myocardial contours and T2* measurement.
    Triadyaksa P; Handayani A; Dijkstra H; Aryanto KY; Pelgrim GJ; Xie X; Willems TP; Prakken NH; Oudkerk M; Sijens PE
    MAGMA; 2016 Feb; 29(1):17-27. PubMed ID: 26530323
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of Myocardial Extracellular Volume Fraction with Cardiac MR Imaging in Thalassemia Major.
    Hanneman K; Nguyen ET; Thavendiranathan P; Ward R; Greiser A; Jolly MP; Butany J; Yang IY; Sussman MS; Wintersperger BJ
    Radiology; 2016 Jun; 279(3):720-30. PubMed ID: 26653680
    [TBL] [Abstract][Full Text] [Related]  

  • 8. T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis.
    Alam MH; Auger D; Smith GC; He T; Vassiliou V; Baksi AJ; Wage R; Drivas P; Feng Y; Firmin DN; Pennell DJ
    J Cardiovasc Magn Reson; 2015 Nov; 17():102. PubMed ID: 26602203
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Myocardial T1 and T2 mapping in severe aortic stenosis: Potential novel insights into the pathophysiology of myocardial remodelling.
    Fehrmann A; Treutlein M; Rudolph T; Rudolph V; Weiss K; Giese D; Bunck AC; Maintz D; Baeßler B
    Eur J Radiol; 2018 Oct; 107():76-83. PubMed ID: 30292277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. T1 and T2 mapping cardiovascular magnetic resonance imaging techniques reveal unapparent myocardial injury in patients with myocarditis.
    Radunski UK; Lund GK; Säring D; Bohnen S; Stehning C; Schnackenburg B; Avanesov M; Tahir E; Adam G; Blankenberg S; Muellerleile K
    Clin Res Cardiol; 2017 Jan; 106(1):10-17. PubMed ID: 27388331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo comparison of myocardial T1 with T2 and T2* in thalassaemia major.
    Feng Y; He T; Carpenter JP; Jabbour A; Alam MH; Gatehouse PD; Greiser A; Messroghli D; Firmin DN; Pennell DJ
    J Magn Reson Imaging; 2013 Sep; 38(3):588-93. PubMed ID: 23371802
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Native T1 and T2 reference values for maltese healthy cohort.
    Yamagata K; Yamagata LM; Abela M; Portanier Mifsud C; Micallef LA; Reichmuth L; Borg A
    Int J Cardiovasc Imaging; 2023 Jan; 39(1):153-159. PubMed ID: 36598695
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
    Pepe A; Positano V; Santarelli MF; Sorrentino F; Cracolici E; De Marchi D; Maggio A; Midiri M; Landini L; Lombardi M
    J Magn Reson Imaging; 2006 May; 23(5):662-8. PubMed ID: 16568436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Myocardial and hepatic iron overload assessment by region-based and pixel-wise T2* mapping analysis: technical pitfalls and clinical warnings.
    Roghi A; Poggiali E; Pedrotti P; Milazzo A; Quattrocchi G; Cassinerio E; Cappellini MD
    J Comput Assist Tomogr; 2015; 39(1):128-33. PubMed ID: 25279849
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of T2* in-line analysis for tissue iron quantification at 1.5 T.
    Alam MH; He T; Auger D; Smith GC; Drivas P; Wage R; Izgi C; Symmonds K; Greiser A; Spottiswoode BS; Anderson L; Firmin D; Pennell DJ
    J Cardiovasc Magn Reson; 2016 Apr; 18(1):23. PubMed ID: 27121114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of MR imaging with T1 and T2* mapping for the determination of hepatic iron overload.
    Henninger B; Kremser C; Rauch S; Eder R; Zoller H; Finkenstedt A; Michaely HJ; Schocke M
    Eur Radiol; 2012 Nov; 22(11):2478-86. PubMed ID: 22645044
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping.
    Singh SP; Jagia P; Ojha V; Seth T; Naik N; Ganga KP; Kumar S
    Indian J Radiol Imaging; 2024 Jan; 34(1):54-59. PubMed ID: 38106847
    [No Abstract]   [Full Text] [Related]  

  • 18. Differences in native T1 and native T2 mapping between patients on hemodialysis and control subjects.
    Graham-Brown MPM; Gulsin GS; Poli F; Parke K; Burton JO; McCann GP
    Eur J Radiol; 2021 Jul; 140():109748. PubMed ID: 33962255
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Iron overload of hematological origin: validation of a screening procedure for cardiac overload by MRI in routine clinical practice.
    Ernst O; Thuret I; Petit P; Ameur F; Loundou AD; de Kerviler E; Izzillo R; Willig AL; Pascal L; Verlhac S; Mordon S; Fenaux P; Rose C
    Diagn Interv Imaging; 2013 Jun; 94(6):601-8. PubMed ID: 23680452
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Qualitative and quantitative magnetic resonance imaging in haemoglobin H disease: screening for iron overload.
    Ooi GC; Chen FE; Chan KN; Tsang KW; Wong YH; Liang R; Chan V; Ngan H
    Clin Radiol; 1999 Feb; 54(2):98-102. PubMed ID: 10050737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.