These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
301 related articles for article (PubMed ID: 26873564)
1. Use of 3D Electroanatomical Navigation (CARTO-3) to Minimize or Eliminate Fluoroscopy Use in the Ablation of Pediatric Supraventricular Tachyarrhythmias. Nagaraju L; Menon D; Aziz PF Pacing Clin Electrophysiol; 2016 Jun; 39(6):574-80. PubMed ID: 26873564 [TBL] [Abstract][Full Text] [Related]
2. A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system. Tuzcu V Pacing Clin Electrophysiol; 2007 Apr; 30(4):519-25. PubMed ID: 17437576 [TBL] [Abstract][Full Text] [Related]
3. First experience with zero-fluoroscopic ablation for supraventricular tachycardias using a novel impedance and magnetic-field-based mapping system. Walsh KA; Galvin J; Keaney J; Keelan E; Szeplaki G Clin Res Cardiol; 2018 Jul; 107(7):578-585. PubMed ID: 29476203 [TBL] [Abstract][Full Text] [Related]
4. Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: a single-centre prospective study. Da Costa A; Ben H'dech M; Romeyer-Bouchard C; Bisch L; Gate-Martinet A; Levallois M; Isaaz K Arch Cardiovasc Dis; 2013; 106(8-9):423-32. PubMed ID: 23906679 [TBL] [Abstract][Full Text] [Related]
5. Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping. Smith G; Clark JM Pacing Clin Electrophysiol; 2007 Apr; 30(4):510-8. PubMed ID: 17437575 [TBL] [Abstract][Full Text] [Related]
6. Catheter ablation for supraventricular tachycardia in children ≤ 20 kg using an electroanatomical system. Koca S; Akdeniz C; Tuzcu V J Interv Card Electrophysiol; 2019 Jun; 55(1):99-104. PubMed ID: 30603855 [TBL] [Abstract][Full Text] [Related]
7. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure. See J; Amora JL; Lee S; Lim P; Teo WS; Tan BY; Ho KL; Lee CW; Ching CK Singapore Med J; 2016 Jul; 57(7):390-5. PubMed ID: 26805664 [TBL] [Abstract][Full Text] [Related]
8. Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children. Papagiannis J; Tsoutsinos A; Kirvassilis G; Sofianidou I; Koussi T; Laskari C; Kiaffas M; Apostolopoulou S; Rammos S Pacing Clin Electrophysiol; 2006 Sep; 29(9):971-8. PubMed ID: 16981921 [TBL] [Abstract][Full Text] [Related]
9. Reducing patient radiation exposure during paediatric SVT ablations: use of CARTO® 3 in concert with "ALARA" principles profoundly lowers total dose. Pass RH; Gates GG; Gellis LA; Nappo L; Ceresnak SR Cardiol Young; 2015 Jun; 25(5):963-8. PubMed ID: 25155609 [TBL] [Abstract][Full Text] [Related]
10. A zero-fluoroscopy approach to cavotricuspid isthmus catheter ablation: comparative analysis of two electroanatomical mapping systems. Macías R; Uribe I; Tercedor L; Jiménez-Jáimez J; Barrio T; Álvarez M Pacing Clin Electrophysiol; 2014 Aug; 37(8):1029-37. PubMed ID: 24628051 [TBL] [Abstract][Full Text] [Related]
11. Consequence of use of lower dose flat plate fluoroscopy in pediatric patients undergoing ablation for supraventricular tachycardia. Spar DS; Anderson JB; Lemen L; Czosek RJ; Knilans TK Am J Cardiol; 2013 Jul; 112(1):85-9. PubMed ID: 23601578 [TBL] [Abstract][Full Text] [Related]
12. Usefulness of three-dimensional non-fluoroscopic mapping in the ablation of typical atrial flutter. Leonelli FM; Tomassoni G; Richey M; Natale A Ital Heart J; 2002 Jun; 3(6):360-5. PubMed ID: 12116800 [TBL] [Abstract][Full Text] [Related]
13. Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience. Stabile G; Scaglione M; del Greco M; De Ponti R; Bongiorni MG; Zoppo F; Soldati E; Marazzi R; Marini M; Gaita F; Iuliano A; Bertaglia E Europace; 2012 Jan; 14(1):60-5. PubMed ID: 21893511 [TBL] [Abstract][Full Text] [Related]
14. Reducing patient radiation dosage during pediatric SVT ablations using an "ALARA" radiation reduction protocol in the modern fluoroscopic era. Gellis LA; Ceresnak SR; Gates GJ; Nappo L; Pass RH Pacing Clin Electrophysiol; 2013 Jun; 36(6):688-94. PubMed ID: 23510152 [TBL] [Abstract][Full Text] [Related]
15. Feasibility of implementation of a "simplified, No-X-Ray, no-lead apron, two-catheter approach" for ablation of supraventricular arrhythmias in children and adults. Stec S; Śledź J; Mazij M; Raś M; Ludwik B; Chrabąszcz M; Śledź A; Banasik M; Bzymek M; Młynarczyk K; Deutsch K; Labus M; Śpikowski J; Szydłowski L J Cardiovasc Electrophysiol; 2014 Aug; 25(8):866-874. PubMed ID: 24654678 [TBL] [Abstract][Full Text] [Related]
16. Exclusion of fluoroscopy use in catheter ablation procedures: six years of experience at a single center. Fernández-Gómez JM; Moriña-Vázquez P; Morales Edel R; Venegas-Gamero J; Barba-Pichardo R; Carranza MH J Cardiovasc Electrophysiol; 2014 Jun; 25(6):638-44. PubMed ID: 24611978 [TBL] [Abstract][Full Text] [Related]
17. Procedural outcomes of fluoroless catheter ablation outside the traditional catheterization lab. Bigelow AM; Smith PC; Timberlake DT; McNinch NL; Smith GL; Lane JR; Clark JM Europace; 2017 Aug; 19(8):1378-1384. PubMed ID: 27915262 [TBL] [Abstract][Full Text] [Related]
19. Efficacy and safety of zero-fluoroscopy ablation for supraventricular tachycardias. Use of optional contact force measurement for zero-fluoroscopy ablation in a clinical routine setting. Seizer P; Bucher V; Frische C; Heinzmann D; Gramlich M; Müller I; Henning A; Hofbeck M; Kerst G; Gawaz M; Schreieck J Herz; 2016 May; 41(3):241-5. PubMed ID: 26462477 [TBL] [Abstract][Full Text] [Related]
20. Non-fluoroscopic catheter visualization using MediGuide™ technology: experience from the first 600 procedures. Sommer P; Richter S; Hindricks G; Rolf S J Interv Card Electrophysiol; 2014 Sep; 40(3):209-14. PubMed ID: 24430081 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]