BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

687 related articles for article (PubMed ID: 26886281)

  • 1. Recurrent laryngeal nerve injury with incomplete loss of electromyography signal during monitored thyroidectomy-evaluation and outcome.
    Wu CW; Hao M; Tian M; Dionigi G; Tufano RP; Kim HY; Jung KY; Liu X; Sun H; Lu IC; Chang PY; Chiang FY
    Langenbecks Arch Surg; 2017 Jun; 402(4):691-699. PubMed ID: 26886281
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correlation Between Electrophysiological Changes and Outcomes of Vocal Cord Function in 1764 Recurrent Laryngeal Nerves with Visual Integrity During Thyroidectomy.
    Yuan Q; Wu G; Hou J; Liao X; Liao Y; Chiang FY
    Thyroid; 2020 May; 30(5):739-745. PubMed ID: 31880997
    [No Abstract]   [Full Text] [Related]  

  • 3. Necessity of Routinely Testing the Proximal and Distal Ends of Exposed Recurrent Laryngeal Nerve During Monitored Thyroidectomy.
    Huang HY; Lien CF; Wang CC; Wang CC; Hwang TZ; Shih YC; Wu CW; Dionigi G; Huang TY; Chiang FY
    Front Endocrinol (Lausanne); 2022; 13():923804. PubMed ID: 35846324
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Warning criterion to predict recurrent laryngeal nerve injury with percentage reduction of the amplitude of V2/R2d in neuromonitoring thyroidectomy.
    Yuan Q; Liao Y; Liao X; Hou J; Zheng L; Liu J; Wang K; Wu G
    Auris Nasus Larynx; 2021 Oct; 48(5):942-948. PubMed ID: 33451885
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study.
    Phelan E; Schneider R; Lorenz K; Dralle H; Kamani D; Potenza A; Sritharan N; Shin J; W Randolph G
    Laryngoscope; 2014 Jun; 124(6):1498-505. PubMed ID: 24307596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery.
    Tomoda C; Hirokawa Y; Uruno T; Takamura Y; Ito Y; Miya A; Kobayashi K; Matsuzuka F; Kuma K; Miyauchi A
    World J Surg; 2006 Jul; 30(7):1230-3. PubMed ID: 16773263
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does extensive dissection of recurrent laryngeal nerve during thyroid operation increase the risk of nerve injury? Evidence from the application of intraoperative neuromonitoring.
    Chiang FY; Lu IC; Tsai CJ; Hsiao PJ; Hsu CC; Wu CW
    Am J Otolaryngol; 2011; 32(6):499-503. PubMed ID: 21306792
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Varied Recurrent Laryngeal Nerve Course Is Associated with Increased Risk of Nerve Dysfunction During Thyroidectomy: Results of the Surgical Anatomy of the Recurrent Laryngeal Nerve in Thyroid Surgery Study, an International Multicenter Prospective Anatomic and Electrophysiologic Study of 1000 Monitored Nerves at Risk from the International Neural Monitoring Study Group.
    Liddy W; Wu CW; Dionigi G; Donatini G; Giles Senyurek Y; Kamani D; Iwata A; Wang B; Okose O; Cheung A; Saito Y; Casella C; Aygun N; Uludag M; Brauckhoff K; Carnaille B; Tunca F; Barczyński M; Kim HY; Favero E; Innaro N; Vamvakidis K; Serpell J; Romanchishen AF; Takami H; Chiang FY; Schneider R; Dralle H; Shin JJ; Abdelhamid Ahmed AH; Randolph GW
    Thyroid; 2021 Nov; 31(11):1730-1740. PubMed ID: 34541890
    [No Abstract]   [Full Text] [Related]  

  • 9. Correlation of final evoked potential amplitudes on intraoperative electromyography of the recurrent laryngeal nerve with immediate postoperative vocal fold function after thyroid and parathyroid surgery.
    Genther DJ; Kandil EH; Noureldine SI; Tufano RP
    JAMA Otolaryngol Head Neck Surg; 2014 Feb; 140(2):124-8. PubMed ID: 24384927
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous or intermittent nerve monitoring.
    Schneider R; Sekulla C; Machens A; Lorenz K; Nguyen Thanh P; Dralle H
    Br J Surg; 2015 Oct; 102(11):1380-7. PubMed ID: 26333134
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous probe stimulation for intraoperative neuromonitoring in total endoscopic thyroidectomy: A preliminary experience.
    Zhang D; Li F; Wu CW; Liu X; Xin J; Chiang FY; Sun H
    Head Neck; 2017 May; 39(5):1001-1007. PubMed ID: 28245074
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prognostic value of intraoperative neural monitoring of the recurrent laryngeal nerve in thyroid surgery.
    Stopa M; Barczyński M
    Langenbecks Arch Surg; 2017 Sep; 402(6):957-964. PubMed ID: 27143020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative nerve monitoring during thyroidectomy: evaluation of signal loss, prognostic value and surgical strategy.
    Gür EO; Haciyanli M; Karaisli S; Haciyanli S; Kamer E; Acar T; Kumkumoglu Y
    Ann R Coll Surg Engl; 2019 Nov; 101(8):589-595. PubMed ID: 31219340
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk.
    Chan WF; Lang BH; Lo CY
    Surgery; 2006 Dec; 140(6):866-72; discussion 872-3. PubMed ID: 17188132
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Surgical strategy during intended total thyroidectomy after loss of EMG signal on the first side of resection].
    Schneider R; Lorenz K; Sekulla C; Machens A; Nguyen-Thanh P; Dralle H
    Chirurg; 2015 Feb; 86(2):154-63. PubMed ID: 24823999
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve during thyroid and parathyroid surgery: Experience with 1,381 nerves at risk.
    Randolph GW; Kamani D
    Laryngoscope; 2017 Jan; 127(1):280-286. PubMed ID: 27389369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative EMG recovery patterns and outcomes after RLN traction-related amplitude decrease during monitored thyroidectomy.
    Chiu KL; Lien CF; Wang CC; Wang CC; Hwang TZ; Shih YC; Yu WV; Wu CW; Dionigi G; Huang TY; Chiang FY
    Front Endocrinol (Lausanne); 2022; 13():888381. PubMed ID: 36034434
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Exclusive real-time monitoring during recurrent laryngeal nerve dissection in conventional monitored thyroidectomy.
    Liu XL; Wu CW; Zhao YS; Wang T; Chen P; Xin JW; Li SJ; Zhang DQ; Zhang G; Fu YT; Zhao LN; Zhou L; Dionigi G; Chiang FY; Sun H
    Kaohsiung J Med Sci; 2016 Mar; 32(3):135-41. PubMed ID: 27106003
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Results of intraoperative neuromonitoring in thyroid surgery and preoperative vocal cord paralysis.
    Lorenz K; Abuazab M; Sekulla C; Schneider R; Nguyen Thanh P; Dralle H
    World J Surg; 2014 Mar; 38(3):582-91. PubMed ID: 24346632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stimulating dissecting instruments during neuromonitoring of RLN in thyroid surgery.
    Chiang FY; Lu IC; Chang PY; Sun H; Wang P; Lu XB; Chen HC; Chen HY; Kim HY; Dionigi G; Wu CW
    Laryngoscope; 2015 Dec; 125(12):2832-7. PubMed ID: 25809677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.