  • 1. Analyzing the performance of ArcCHECK diode array detector for VMAT plan.
    Thiyagarajan R; Nambiraj A; Sinha SN; Yadav G; Kumar A; Subramani V; Kothandaraman
    Rep Pract Oncol Radiother; 2016; 21(1):50-6. PubMed ID: 26900358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-T-130: IMAT Patient Specific Quality Assurance Using ArcCHECK Diode Array Detector.
    Thiyagarajan R; Sinha S; Yadav G; Ashokkumar S; Raman K; Mishra M; Nambiraj NA
    Med Phys; 2012 Jun; 39(6Part11):3733. PubMed ID: 28517117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement comparison and Monte Carlo analysis for volumetric-modulated arc therapy (VMAT) delivery verification using the ArcCHECK dosimetry system.
    Lin MH; Koren S; Veltchev I; Li J; Wang L; Price RA; Ma CM
    J Appl Clin Med Phys; 2013 May; 14(2):3929. PubMed ID: 23470927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. VMAT QA: measurement-guided 4D dose reconstruction on a patient.
    Nelms BE; Opp D; Robinson J; Wolf TK; Zhang G; Moros E; Feygelman V
    Med Phys; 2012 Jul; 39(7):4228-38. PubMed ID: 22830756
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Initial clinical experience with ArcCHECK for IMRT/VMAT QA.
    Aristophanous M; Suh Y; Chi PC; Whittlesey LJ; LaNeave S; Martel MK
    J Appl Clin Med Phys; 2016 Sep; 17(5):20-33. PubMed ID: 27685107
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT).
    Li G; Bai S; Chen N; Henderson L; Wu K; Xiao J; Zhang Y; Jiang Q; Jiang X
    J Appl Clin Med Phys; 2013 Sep; 14(5):13-24. PubMed ID: 24036856
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
    O'Daniel J; Das S; Wu QJ; Yin FF
    Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
    [TBL] [Abstract][Full Text] [Related]  

  • 8. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification.
    Infusino E; Mameli A; Conti R; Gaudino D; Stimato G; Bellesi L; D'Angelillo RM; Ramella S; Benassi M; Trodella L
    Med Dosim; 2014; 39(3):276-81. PubMed ID: 25088815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans.
    Li G; Wu K; Peng G; Zhang Y; Bai S
    Med Dosim; 2014; 39(4):309-13. PubMed ID: 24958705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel method for routine quality assurance of volumetric-modulated arc therapy.
    Wang Q; Dai J; Zhang K
    Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The quality assurance of volumetric modulated arc therapy (VMAT) plans for early stage prostate cancer: a technical note.
    Elith CA; Dempsey SE; Cao F; Farshadi A; Warren-Forward HM
    J Med Radiat Sci; 2014 Dec; 61(4):261-266. PubMed ID: 25598980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA.
    Olch AJ
    Med Phys; 2012 Jan; 39(1):81-6. PubMed ID: 22225277
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA.
    Chaswal V; Weldon M; Gupta N; Chakravarti A; Rong Y
    J Appl Clin Med Phys; 2014 Jul; 15(4):4832. PubMed ID: 25207411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a novel ArcCHECK(™) insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities.
    Fakir H; Gaede S; Mulligan M; Chen JZ
    Med Phys; 2012 Jul; 39(7):4203-8. PubMed ID: 22830753
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy.
    Han C; Yi J; Zhu K; Zhou Y; Ai Y; Zheng X; Xie C; Jin X
    J Appl Clin Med Phys; 2020 Nov; 21(11):98-104. PubMed ID: 33001540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation and IMRT/VMAT delivery quality of a preconfigured fast-rotating O-ring linac system.
    De Roover R; Crijns W; Poels K; Michiels S; Nulens A; Vanstraelen B; Petillion S; De Brabandere M; Haustermans K; Depuydt T
    Med Phys; 2019 Jan; 46(1):328-339. PubMed ID: 30417523
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of the Acuros XB spatial discretization error on ArcCHECK VMAT QA for small-field SBRT.
    He C; Pant A; Le AH
    J Appl Clin Med Phys; 2023 Sep; 24(9):e14100. PubMed ID: 37563870
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy.
    Arumugam S; Xing A; Jameson M; Holloway L
    Med Phys; 2013 Jul; 40(7):071724. PubMed ID: 23822428
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance.
    Yewondwossen M
    Med Dosim; 2012; 37(3):250-6. PubMed ID: 22189031
    [TBL] [Abstract][Full Text] [Related]  