These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 26903106)

  • 1. Acoustic and microwave tests in a cylindrical cavity for acoustic gas thermometry at high temperature.
    Zhang K; Feng XJ; Gillis K; Moldover M; Zhang JT; Lin H; Qu JF; Duan YN
    Philos Trans A Math Phys Eng Sci; 2016 Mar; 374(2064):20150049. PubMed ID: 26903106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of the Boltzmann constant with cylindrical acoustic gas thermometry: new and previous results combined.
    Feng XJ; Zhang JT; Lin H; Gillis KA; Mehl JB; Moldover MR; Zhang K; Duan YN
    Metrologia; 2017 Oct; 54(5):748-762. PubMed ID: 29332954
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Progress Towards a Gas-Flow Standard using Microwave and Acoustic Resonances.
    Pope JG; Gillis KA; Moldover MR; Mehl JB; Harman E
    Flow Meas Instrum; 2019; 69():. PubMed ID: 32116415
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Perturbations From Ducts on the Modes of Acoustic Thermometers.
    Gillis KA; Lin H; Moldover MR
    J Res Natl Inst Stand Technol; 2009; 114(5):263-85. PubMed ID: 27504227
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of the Boltzmann constant using a quasi-spherical acoustic resonator.
    Pitre L; Sparasci F; Truong D; Guillou A; Risegari L; Himbert ME
    Philos Trans A Math Phys Eng Sci; 2011 Oct; 369(1953):4014-27. PubMed ID: 21930563
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimates of the difference between thermodynamic temperature and the International Temperature Scale of 1990 in the range 118 K to 303 K.
    Underwood R; de Podesta M; Sutton G; Stanger L; Rusby R; Harris P; Morantz P; Machin G
    Philos Trans A Math Phys Eng Sci; 2016 Mar; 374(2064):20150048. PubMed ID: 26903104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Refractive-index gas thermometry.
    Rourke PMC; Gaiser C; Gao B; Ripa DM; Moldover MR; Pitre L; Underwood RJ
    Metrologia; 2019; 56():. PubMed ID: 31274930
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of two stacked cylindrical dielectric resonators in a TE₁₀₂ microwave cavity for magnetic resonance spectroscopy.
    Mattar SM; Elnaggar SY
    J Magn Reson; 2011 Apr; 209(2):174-82. PubMed ID: 21300559
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Whispering Gallery Mode Resonators for Precision Temperature Metrology Applications.
    Gugliandolo G; Tabandeh S; Rosso L; Smorgon D; Fernicola V
    Sensors (Basel); 2021 Apr; 21(8):. PubMed ID: 33920723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Toward the realization of a primary low-pressure standard using a superconducting microwave resonator.
    Gambette P; Gavioso RM; Madonna Ripa D; Plimmer MD; Sparasci F; Pitre L
    Rev Sci Instrum; 2023 Mar; 94(3):035112. PubMed ID: 37012751
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coupled modes, frequencies and fields of a dielectric resonator and a cavity using coupled mode theory.
    Elnaggar SY; Tervo R; Mattar SM
    J Magn Reson; 2014 Jan; 238():1-7. PubMed ID: 24246950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Speed-of-Sound Measurements in (Argon + Carbon Dioxide) over the Temperature Range from (275 to 500) K at Pressures up to 8 MPa.
    Wegge R; McLinden MO; Perkins RA; Richter M; Span R
    J Chem Thermodyn; 2016 Aug; 99():54-64. PubMed ID: 27458321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual-laser-induced Breakdown Thermometry via Sound Speed Measurement:A New Procedure for Improved Spatiotemporal Resolution.
    Li S; Weng W; Kong C; Aldén M; Li Z
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32423122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Kelvin and Temperature Measurements.
    Mangum BW; Furukawa GT; Kreider KG; Meyer CW; Ripple DC; Strouse GF; Tew WL; Moldover MR; Johnson BC; Yoon HW; Gibson CE; Saunders RD
    J Res Natl Inst Stand Technol; 2001; 106(1):105-49. PubMed ID: 27500019
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Whispering gallery mode nanodisk resonator based on layered metal-dielectric waveguide.
    Lou F; Yan M; Thylen L; Qiu M; Wosinski L
    Opt Express; 2014 Apr; 22(7):8490-502. PubMed ID: 24718221
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Speed of Sound Measurements in Dense Siloxane D
    Mercier B; Chandrasekaran NB; Colonna P
    J Chem Eng Data; 2023 Mar; 68(3):561-573. PubMed ID: 36930755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of condenser microphones under different environmental conditions for accurate speed of sound measurements with acoustic resonators.
    Guianvarc'h C; Gavioso RM; Benedetto G; Pitre L; Bruneau M
    Rev Sci Instrum; 2009 Jul; 80(7):074901. PubMed ID: 19655971
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Highly sensitive photoacoustic gas sensor with micro-embedded acoustic resonator for gas leakage detection.
    Zhang B; Jia Y; Zhao B; Zhu X; Shi Y
    Opt Lett; 2023 Aug; 48(16):4201-4204. PubMed ID: 37581992
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Progress towards the determination of thermodynamic temperature with ultra-low uncertainty.
    Gavioso RM; Ripa DM; Steur PP; Gaiser C; Zandt T; Fellmuth B; de Podesta M; Underwood R; Sutton G; Pitre L; Sparasci F; Risegari L; Gianfrani L; Castrillo A; Machin G
    Philos Trans A Math Phys Eng Sci; 2016 Mar; 374(2064):20150046. PubMed ID: 26903096
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Upconversion Loop Oscillator Axion Detection Experiment: A Precision Frequency Interferometric Axion Dark Matter Search with a Cylindrical Microwave Cavity.
    Thomson CA; McAllister BT; Goryachev M; Ivanov EN; Tobar ME
    Phys Rev Lett; 2021 Feb; 126(8):081803. PubMed ID: 33709759
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.