1. Biomechanical Comparison of Locking Compression Plate and Limited Contact Dynamic Compression Plate Combined with an Intramedullary Rod in a Canine Femoral Fracture-Gap Model. Matres-Lorenzo L; Diop A; Maurel N; Boucton MC; Bernard F; Bernardé A Vet Surg; 2016 Apr; 45(3):319-26. PubMed ID: 26909507 [TBL] [Abstract][Full Text] [Related]
2. An in vitro biomechanical study of bone plate and interlocking nail in a canine diaphyseal femoral fracture model. Bernarde A; Diop A; Maurel N; Viguier E Vet Surg; 2001; 30(5):397-408. PubMed ID: 11555814 [TBL] [Abstract][Full Text] [Related]
3. Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model. Irubetagoyena I; Verset M; Palierne S; Swider P; Autefage A Vet Comp Orthop Traumatol; 2013; 26(6):479-88. PubMed ID: 24080774 [TBL] [Abstract][Full Text] [Related]
4. In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate. Aguila AZ; Manos JM; Orlansky AS; Todhunter RJ; Trotter EJ; Van der Meulen MC Vet Comp Orthop Traumatol; 2005; 18(4):220-6. PubMed ID: 16594390 [TBL] [Abstract][Full Text] [Related]
5. A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model. Bruce CW; Gibson TW; Runciman RJ Vet Comp Orthop Traumatol; 2014; 27(6):430-5. PubMed ID: 25345445 [TBL] [Abstract][Full Text] [Related]
6. A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model. Filipowicz D; Lanz O; McLaughlin R; Elder S; Werre S Vet Comp Orthop Traumatol; 2009; 22(4):270-7. PubMed ID: 19597629 [TBL] [Abstract][Full Text] [Related]
7. An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of diaphyseal femur fractures in immature horses. Radcliffe RM; Lopez MJ; Turner TA; Watkins JP; Radcliffe CH; Markel MD Vet Surg; 2001; 30(2):179-90. PubMed ID: 11230773 [TBL] [Abstract][Full Text] [Related]
8. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora. Goh CS; Santoni BG; Puttlitz CM; Palmer RH Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers. Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152 [TBL] [Abstract][Full Text] [Related]
10. The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model. Gardner MJ; Brophy RH; Campbell D; Mahajan A; Wright TM; Helfet DL; Lorich DG J Orthop Trauma; 2005 Oct; 19(9):597-603. PubMed ID: 16247303 [TBL] [Abstract][Full Text] [Related]
11. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint. Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267 [TBL] [Abstract][Full Text] [Related]
12. Ex vivo biomechanical comparison of a 3.5 mm locking compression plate applied cranially and a 2.7 mm locking compression plate applied medially in a gap model of the distal aspect of the canine radius. Uhl JM; Kapatkin AS; Garcia TC; Stover SM Vet Surg; 2013 Oct; 42(7):840-6. PubMed ID: 24033354 [TBL] [Abstract][Full Text] [Related]
13. Biomechanical Comparison of Locking Compression Plate versus Positive Profile Pins and Polymethylmethacrylate for Stabilization of the Canine Lumbar Vertebrae. Sturges BK; Kapatkin AS; Garcia TC; Anwer C; Fukuda S; Hitchens PL; Wisner T; Hayashi K; Stover SM Vet Surg; 2016 Apr; 45(3):309-18. PubMed ID: 27007649 [TBL] [Abstract][Full Text] [Related]
14. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware. Windolf M; Klos K; Wähnert D; van der Pol B; Radtke R; Schwieger K; Jakob RP BMC Musculoskelet Disord; 2010 May; 11():95. PubMed ID: 20492707 [TBL] [Abstract][Full Text] [Related]
15. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws. Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical comparison of a locking compression plate combined with an intramedullary pin or a polyetheretherketone rod in a cadaveric canine tibia gap model. Beierer LH; Glyde M; Day RE; Hosgood GL Vet Surg; 2014 Nov; 43(8):1032-8. PubMed ID: 25132257 [TBL] [Abstract][Full Text] [Related]
17. The effect of intramedullary pin size and monocortical screw configuration on locking compression plate-rod constructs in an in vitro fracture gap model. Pearson T; Glyde M; Hosgood G; Day R Vet Comp Orthop Traumatol; 2015; 28(2):95-103. PubMed ID: 25633043 [TBL] [Abstract][Full Text] [Related]
18. In vitro biomechanical comparison of dynamic compression plates with a rough contact surface and a polished contact surface for fixation of osteotomized equine third metacarpal bones. Sod GA; Riggs LM; Mitchell CF; Martin GS; Gill MS Vet Surg; 2011 Jul; 40(5):579-85. PubMed ID: 21539578 [TBL] [Abstract][Full Text] [Related]
19. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model. Malenfant RC; Sod GA Vet Surg; 2014 May; 43(4):465-70. PubMed ID: 24720361 [TBL] [Abstract][Full Text] [Related]
20. A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model. Snow M; Thompson G; Turner PG J Orthop Trauma; 2008 Feb; 22(2):121-5. PubMed ID: 18349780 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]