BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 26912761)

  • 1. A Comprehensive Evaluation of the Bruker Biotyper MS and Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Systems for Identification of Yeasts, Part of the National China Hospital Invasive Fungal Surveillance Net (CHIF-NET) Study, 2012 to 2013.
    Wang H; Fan YY; Kudinha T; Xu ZP; Xiao M; Zhang L; Fan X; Kong F; Xu YC
    J Clin Microbiol; 2016 May; 54(5):1376-80. PubMed ID: 26912761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the Bruker Biotyper and VITEK MS Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Systems Using a Formic Acid Extraction Method to Identify Common and Uncommon Yeast Isolates.
    Lee HS; Shin JH; Choi MJ; Won EJ; Kee SJ; Kim SH; Shin MG; Suh SP
    Ann Lab Med; 2017 May; 37(3):223-230. PubMed ID: 28224768
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for non-albicans Candida and uncommon yeast isolates.
    Teke L; Barış A; Bayraktar B
    J Microbiol Methods; 2021 Jun; 185():106232. PubMed ID: 33961963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Bruker Biotyper and Vitek MS for the identification of Candida tropicalis on different solid culture media.
    Wang H; Li Y; Fan X; Chiueh TS; Xu YC; Hsueh PR
    J Microbiol Immunol Infect; 2019 Aug; 52(4):604-611. PubMed ID: 29191475
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts.
    Jamal WY; Ahmad S; Khan ZU; Rotimi VO
    Int J Infect Dis; 2014 Sep; 26():167-70. PubMed ID: 25080355
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Autof MS 1000 and Vitek MS MALDI-TOF MS System in Identification of Closely-Related Yeasts Causing Invasive Fungal Diseases.
    Yi Q; Xiao M; Fan X; Zhang G; Yang Y; Zhang JJ; Duan SM; Cheng JW; Li Y; Zhou ML; Yu SY; Huang JJ; Chen XF; Hou X; Kong F; Kudinha T; Xu YC
    Front Cell Infect Microbiol; 2021; 11():628828. PubMed ID: 33680993
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Yeast identification algorithm based on use of the Vitek MS system selectively supplemented with ribosomal DNA sequencing: proposal of a reference assay for invasive fungal surveillance programs in China.
    Zhang L; Xiao M; Wang H; Gao R; Fan X; Brown M; Gray TJ; Kong F; Xu YC
    J Clin Microbiol; 2014 Feb; 52(2):572-7. PubMed ID: 24478490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advantages of using matrix-assisted laser desorption ionization-time of flight mass spectrometry as a rapid diagnostic tool for identification of yeasts and mycobacteria in the clinical microbiological laboratory.
    Chen JH; Yam WC; Ngan AH; Fung AM; Woo WL; Yan MK; Choi GK; Ho PL; Cheng VC; Yuen KY
    J Clin Microbiol; 2013 Dec; 51(12):3981-7. PubMed ID: 24048537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Side by Side Comparison of Bruker Biotyper and VITEK MS: Utility of MALDI-TOF MS Technology for Microorganism Identification in a Public Health Reference Laboratory.
    Lévesque S; Dufresne PJ; Soualhine H; Domingo MC; Bekal S; Lefebvre B; Tremblay C
    PLoS One; 2015; 10(12):e0144878. PubMed ID: 26658918
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the accuracy of two conventional phenotypic methods and two MALDI-TOF MS systems with that of DNA sequencing analysis for correctly identifying clinically encountered yeasts.
    Chao QT; Lee TF; Teng SH; Peng LY; Chen PH; Teng LJ; Hsueh PR
    PLoS One; 2014; 9(10):e109376. PubMed ID: 25330370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Vitek MS and Bruker Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Systems for Identification of Chryseobacterium Isolates from Clinical Specimens and Report of Uncommon Chryseobacterium Infections in Humans.
    Lin JN; Teng SH; Lai CH; Yang CH; Huang YH; Lin HF; Lin HH
    J Clin Microbiol; 2018 Nov; 56(11):. PubMed ID: 30135228
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry systems for identification of yeasts of medical importance.
    Mancini N; De Carolis E; Infurnari L; Vella A; Clementi N; Vaccaro L; Ruggeri A; Posteraro B; Burioni R; Clementi M; Sanguinetti M
    J Clin Microbiol; 2013 Jul; 51(7):2453-7. PubMed ID: 23678071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of two matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for the identification of Candida species.
    Lacroix C; Gicquel A; Sendid B; Meyer J; Accoceberry I; François N; Morio F; Desoubeaux G; Chandenier J; Kauffmann-Lacroix C; Hennequin C; Guitard J; Nassif X; Bougnoux ME
    Clin Microbiol Infect; 2014 Feb; 20(2):153-8. PubMed ID: 23594150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the rapid identification of yeasts causing bloodstream infections.
    Ghosh AK; Paul S; Sood P; Rudramurthy SM; Rajbanshi A; Jillwin TJ; Chakrabarti A
    Clin Microbiol Infect; 2015 Apr; 21(4):372-8. PubMed ID: 25658527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved clinical laboratory identification of human pathogenic yeasts by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.
    Bader O; Weig M; Taverne-Ghadwal L; Lugert R; Gross U; Kuhns M
    Clin Microbiol Infect; 2011 Sep; 17(9):1359-65. PubMed ID: 20946411
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison and optimization of two MALDI-TOF MS platforms for the identification of medically relevant yeast species.
    Pence MA; McElvania TeKippe E; Wallace MA; Burnham CA
    Eur J Clin Microbiol Infect Dis; 2014 Oct; 33(10):1703-12. PubMed ID: 24800928
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rapid identification of 6328 isolates of pathogenic yeasts using MALDI-ToF MS and a simplified, rapid extraction procedure that is compatible with the Bruker Biotyper platform and database.
    Fraser M; Brown Z; Houldsworth M; Borman AM; Johnson EM
    Med Mycol; 2016 Jan; 54(1):80-8. PubMed ID: 26591008
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of biomarker based Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and conventional methods in the identification of clinically relevant bacteria and yeast.
    Kassim A; Pflüger V; Premji Z; Daubenberger C; Revathi G
    BMC Microbiol; 2017 May; 17(1):128. PubMed ID: 28545528
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Bruker Biotyper
    Hankins JD; Amerson-Brown MH; Brown CA; Riegler AN; Muldrew KL; Dunn JJ
    Future Microbiol; 2023 Jun; 18():553-561. PubMed ID: 37317856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of species-level identification of yeast isolates from blood cultures from 10 university hospitals in South Korea by use of the matrix-assisted laser desorption ionization-time of flight mass spectrometry-based Vitek MS system.
    Won EJ; Shin JH; Lee K; Kim MN; Lee HS; Park YJ; Joo MY; Kim SH; Shin MG; Suh SP; Ryang DW
    J Clin Microbiol; 2013 Sep; 51(9):3063-5. PubMed ID: 23784123
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.