These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 26914012)

  • 1. Body temperature mapping in critically ill newborn infants nursed under radiant warmers during intensive care.
    Chaseling GK; Molgat-Seon Y; Daboval T; Chou S; Jay O
    J Perinatol; 2016 Jul; 36(7):540-3. PubMed ID: 26914012
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimal thermal management for low birth weight infants nursed under high-powered radiant warmers.
    Malin SW; Baumgart S
    Pediatrics; 1987 Jan; 79(1):47-54. PubMed ID: 3797170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing neonatal heat balance and physiological strain in newborn infants nursed under radiant warmers in intensive care with fentanyl sedation.
    Molgat-Seon Y; Daboval T; Chou S; Jay O
    Eur J Appl Physiol; 2014 Dec; 114(12):2539-49. PubMed ID: 25115506
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiant heat loss versus radiant heat gain in premature neonates under radiant warmers.
    Baumgart S
    Biol Neonate; 1990; 57(1):10-20. PubMed ID: 2302433
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Head insulation for premature infants in servocontrolled incubators and radiant warmers.
    Templeman MC; Bell EF
    Am J Dis Child; 1986 Sep; 140(9):940-2. PubMed ID: 3740003
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inspired gas temperature in ventilated neonates.
    Davies MW; Dunster KR; Cartwright DW
    Pediatr Pulmonol; 2004 Jul; 38(1):50-4. PubMed ID: 15170873
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The heat balance of small babies nursed in incubators and under radiant warmers.
    Wheldon AE; Rutter N
    Early Hum Dev; 1982 Apr; 6(2):131-43. PubMed ID: 7094851
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal stability of premature infants during routine care under radiant warmers.
    Seguin JH; Vieth R
    Arch Dis Child Fetal Neonatal Ed; 1996 Mar; 74(2):F137-8. PubMed ID: 8777664
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of four different radiant warmer temperature set-points used for rewarming neonates.
    Motil KJ; Blackburn MG; Pleasure JR
    J Pediatr; 1974 Oct; 85(4):546-50. PubMed ID: 4443866
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Thermal comfort in preterm babies. Infra-red colour thermography findings. Preliminary report].
    Musialik-Swietlińska E; Wojaczyńska-Stanek K; Swietliński J; Koprowski R; Krawczyk R; Bober K
    Med Wieku Rozwoj; 2011; 15(1):79-83. PubMed ID: 21786516
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous measurement of core body temperature in preterm infants.
    Dollberg S; Rimon A; Atherton HD; Hoath SB
    Am J Perinatol; 2000; 17(5):257-64. PubMed ID: 11110344
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiant energy and insensible water loss in the premature newborn infant nursed under a radiant warmer.
    Baumgart S
    Clin Perinatol; 1982 Oct; 9(3):483-503. PubMed ID: 6761034
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight.
    Duran R; Vatansever U; Acunaş B; Süt N
    J Paediatr Child Health; 2009; 45(7-8):444-7. PubMed ID: 19712180
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of transcutaneous monitor electrode heat on skin servo-controlled environments.
    Seguin J
    J Perinatol; 1992 Sep; 12(3):276-80. PubMed ID: 1432287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Energy metabolism and substrate utilization in low birth weight neonates under radiant warmers.
    Marks KH; Nardis EE; Momin MN
    Pediatrics; 1986 Sep; 78(3):465-72. PubMed ID: 3748681
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiovascular changes in preterm infants nursed under radiant warmers.
    Walther FJ; Wu PY; Siassi B
    Pediatrics; 1987 Aug; 80(2):235-9. PubMed ID: 3615094
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Water loss from the skin of term and preterm infants nursed under a radiant heater.
    Kjartansson S; Arsan S; Hammarlund K; Sjörs G; Sedin G
    Pediatr Res; 1995 Feb; 37(2):233-8. PubMed ID: 7731762
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Minimal oxygen consumption in infants cared for under overhead radiant warmers compared with conventional incubators.
    Darnall RA; Ariagno RL
    J Pediatr; 1978 Aug; 93(2):283-7. PubMed ID: 678328
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement.
    Moran JL; Peter JV; Solomon PJ; Grealy B; Smith T; Ashforth W; Wake M; Peake SL; Peisach AR
    Crit Care Med; 2007 Jan; 35(1):155-64. PubMed ID: 17095941
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measuring skin temperature in premature infants. Comparison of infrared telethermography and electric contact thermometry].
    Hanssler L; Breukmann H
    Klin Padiatr; 1992; 204(5):355-8. PubMed ID: 1405422
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.