BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 26914660)

  • 1. Donor sclera-wrapped acrylic orbital implants following enucleation: experience in 179 patients in the Netherlands.
    Jongman HP; Marinkovic M; Notting I; Koetsier L; Swart W; Schalij-Delfos NE; Bleeker J; Jager MJ; Luyten GP
    Acta Ophthalmol; 2016 May; 94(3):253-6. PubMed ID: 26914660
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants.
    Arat YO; Shetlar DJ; Boniuk M
    Ophthalmic Plast Reconstr Surg; 2003 May; 19(3):189-93. PubMed ID: 12918552
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Porous orbital implants, wraps, and PEG placement in the pediatric population after enucleation.
    Wang JK; Liao SL; Lin LL; Kao SC; Tseng HS
    Am J Ophthalmol; 2007 Jul; 144(1):109-116. PubMed ID: 17499206
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anterior surface breakdown and implant extrusion following secondary alloplastic orbital implantation surgery.
    Axmann S; Paridaens D
    Acta Ophthalmol; 2018 May; 96(3):310-313. PubMed ID: 29220117
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complications of sclera-covered enucleation implants.
    Custer PL; McCaffery S
    Ophthalmic Plast Reconstr Surg; 2006; 22(4):269-73. PubMed ID: 16855498
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exposure rates of wrapped and unwrapped orbital implants following enucleation.
    Li T; Shen J; Duffy MT
    Ophthalmic Plast Reconstr Surg; 2001 Nov; 17(6):431-5. PubMed ID: 11766024
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Orbital implants in retinoblastoma patients: 23 years of experience and a review of the literature.
    Mourits DL; Moll AC; Bosscha MI; Tan HS; Hartong DT
    Acta Ophthalmol; 2016 Mar; 94(2):165-74. PubMed ID: 26603132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of autogenous sclera as wrapping material in hydroxyapatite implantation.
    Yoon JS; Lew H; Kook KH; Lee SY
    Ophthalmologica; 2009; 223(1):7-11. PubMed ID: 18849630
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Exposure rate of hydroxyapatite orbital implants a 15-year experience of 802 cases.
    Yoon JS; Lew H; Kim SJ; Lee SY
    Ophthalmology; 2008 Mar; 115(3):566-572.e2. PubMed ID: 17854900
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Orbital implants in enucleation surgery: a report by the American Academy of Ophthalmology.
    Custer PL; Kennedy RH; Woog JJ; Kaltreider SA; Meyer DR
    Ophthalmology; 2003 Oct; 110(10):2054-61. PubMed ID: 14522788
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Secondary orbital ball implants after enucleation and evisceration: surgical management, morbidity, and long-term outcome.
    Quaranta-Leoni FM; Sposato S; Lorenzano D
    Ophthalmic Plast Reconstr Surg; 2015; 31(2):115-8. PubMed ID: 25025388
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prevention of exposure of porous orbital implants following enucleation.
    Wang JK; Liao SL; Lai PC; Lin LL
    Am J Ophthalmol; 2007 Jan; 143(1):61-67. PubMed ID: 17109809
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the exposure rate of wrapped hydroxyapatite (Bio-Eye) versus unwrapped porous polyethylene (Medpor) orbital implants in enucleated patients.
    Tabatabaee Z; Mazloumi M; Rajabi MT; Khalilzadeh O; Kassaee A; Moghimi S; Eftekhar H; Goldberg RA
    Ophthalmic Plast Reconstr Surg; 2011; 27(2):114-8. PubMed ID: 20829725
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety of unwrapped spherical orbital implants.
    Perry JD; Tam RC
    Ophthalmic Plast Reconstr Surg; 2004 Jul; 20(4):281-4. PubMed ID: 15266141
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polytetrafluoroethylene as a wrapping material for a hydroxyapatite orbital implant.
    Kao LY
    Ophthalmic Plast Reconstr Surg; 2000 Jul; 16(4):286-8. PubMed ID: 10923976
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Scleral wrap increases the long-term complication risk of bone-derived hydroxyapatite orbital implants.
    Toh T; Bevin TH; Molteno AC
    Clin Exp Ophthalmol; 2008 Nov; 36(8):756-61. PubMed ID: 19128381
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Porous polyethylene orbital implant in the pediatric population.
    Iordanidou V; De Potter P
    Am J Ophthalmol; 2004 Sep; 138(3):425-9. PubMed ID: 15364225
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative motility of hydroxyapatite and alloplastic enucleation implants.
    Custer PL; Trinkaus KM; Fornoff J
    Ophthalmology; 1999 Mar; 106(3):513-6. PubMed ID: 10080207
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mersilene mesh versus sclera in wrapping hydroxyapatite orbital implants.
    Kassaee A; Kashkouli MB; Panjtanpanah M; Sadeghi A; Tabatabaee Z
    Ophthalmic Plast Reconstr Surg; 2006; 22(1):41-4. PubMed ID: 16418664
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydroxyapatite versus polyethylene orbital implants for patients undergoing enucleation for uveal melanoma.
    Chao DL; Harbour JW
    Can J Ophthalmol; 2015 Apr; 50(2):151-4. PubMed ID: 25863856
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.