207 related articles for article (PubMed ID: 26920509)
1. The influence of contact ratio and its location on the primary stability of cementless total hip arthroplasty: A finite element analysis.
Reimeringer M; Nuño N
J Biomech; 2016 May; 49(7):1064-1070. PubMed ID: 26920509
[TBL] [Abstract][Full Text] [Related]
2. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.
Russell RD; Huo MH; Rodrigues DC; Kosmopoulos V
Technol Health Care; 2016 Nov; 24(6):865-872. PubMed ID: 27434281
[TBL] [Abstract][Full Text] [Related]
3. Patient-specific three-dimensional evaluation of interface micromotion in two different short stem designs in cementless total hip arthroplasty: a finite element analysis.
Kanaizumi A; Suzuki D; Nagoya S; Teramoto A; Yamashita T
J Orthop Surg Res; 2022 Sep; 17(1):437. PubMed ID: 36175915
[TBL] [Abstract][Full Text] [Related]
4. The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis.
Reimeringer M; Nuño N; Desmarais-Trépanier C; Lavigne M; Vendittoli PA
Comput Methods Biomech Biomed Engin; 2013; 16(11):1221-31. PubMed ID: 22452543
[TBL] [Abstract][Full Text] [Related]
5. Statistical analysis of interfacial gap in a cementless stem FE model.
Park Y; Choi D; Hwang DS; Yoon YS
J Biomech Eng; 2009 Feb; 131(2):021016. PubMed ID: 19102575
[TBL] [Abstract][Full Text] [Related]
6. Influence of collars on the primary stability of cementless femoral stems: A finite element study using a diverse patient cohort.
Al-Dirini RMA; Huff D; Zhang J; Besier T; Clement JG; Taylor M
J Orthop Res; 2018 Apr; 36(4):1185-1195. PubMed ID: 28940776
[TBL] [Abstract][Full Text] [Related]
7. Prediction of micromotion initiation of an implanted femur under physiological loads and constraints using the finite element method.
Andreaus U; Colloca M
Proc Inst Mech Eng H; 2009 Jul; 223(5):589-605. PubMed ID: 19623912
[TBL] [Abstract][Full Text] [Related]
8. Primary stability of cementless stem in THA improved with reduced interfacial gaps.
Park Y; Shin H; Choi D; Albert C; Yoon YS
J Biomech Eng; 2008 Apr; 130(2):021008. PubMed ID: 18412495
[TBL] [Abstract][Full Text] [Related]
9. Influence of offset on osseointegration in cementless total hip arthroplasty: A finite element study.
Meisterhans M; Dimitriou D; Fasser MR; Hoch A; Jud L; Zingg PO
J Orthop Res; 2024 Jul; 42(7):1566-1576. PubMed ID: 38376065
[TBL] [Abstract][Full Text] [Related]
10. Effect of bone material properties on the initial stability of a cementless hip stem: a finite element study.
Wong AS; New AM; Isaacs G; Taylor M
Proc Inst Mech Eng H; 2005 Jul; 219(4):265-75. PubMed ID: 16050217
[TBL] [Abstract][Full Text] [Related]
11. Evaluating the primary stability of standard vs lateralised cementless femoral stems - A finite element study using a diverse patient cohort.
Al-Dirini RMA; Martelli S; Huff D; Zhang J; Clement JG; Besier T; Taylor M
Clin Biomech (Bristol, Avon); 2018 Nov; 59():101-109. PubMed ID: 30219523
[TBL] [Abstract][Full Text] [Related]
12. Primary stability of a cementless modular revision hip stem in relation with the femoral defect size: A biomechanical study.
Ellenrieder M; Souffrant R; Schulze C; Kluess D; Mittelmeier W; Bader R
J Orthop Surg (Hong Kong); 2020; 28(3):2309499020948991. PubMed ID: 32909886
[TBL] [Abstract][Full Text] [Related]
13. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
[TBL] [Abstract][Full Text] [Related]
14. Influence of femoral stem geometry, material and extent of porous coating on bone ingrowth and atrophy in cementless total hip arthroplasty: an iterative finite element model.
Folgado J; Fernandes PR; Jacobs CR; Pellegrini VD
Comput Methods Biomech Biomed Engin; 2009 Apr; 12(2):135-45. PubMed ID: 19242833
[TBL] [Abstract][Full Text] [Related]
15. Factors influencing initial cup stability in total hip arthroplasty.
Amirouche F; Solitro G; Broviak S; Gonzalez M; Goldstein W; Barmada R
Clin Biomech (Bristol, Avon); 2014 Dec; 29(10):1177-85. PubMed ID: 25266242
[TBL] [Abstract][Full Text] [Related]
16. Numerical simulation of the insertion process of an uncemented hip prosthesis in order to evaluate the influence of residual stress and contact distribution on the stem initial stability.
Monea AG; Pastrav LC; Mulier M; Van der Perre G; Jaecques SV
Comput Methods Biomech Biomed Engin; 2014; 17(3):263-76. PubMed ID: 22548243
[TBL] [Abstract][Full Text] [Related]
17. Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.
Malfroy Camine V; Rüdiger HA; Pioletti DP; Terrier A
Int Orthop; 2018 Jan; 42(1):49-57. PubMed ID: 28589313
[TBL] [Abstract][Full Text] [Related]
18. Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation.
Matsuyama K; Ishidou Y; Guo YM; Kakoi H; Setoguchi T; Nagano S; Kawamura I; Maeda S; Komiya S
BMC Musculoskelet Disord; 2016 Sep; 17(1):397. PubMed ID: 27642748
[TBL] [Abstract][Full Text] [Related]
19. Subject specific finite element analysis of implant stability for a cementless femoral stem.
Pettersen SH; Wik TS; Skallerud B
Clin Biomech (Bristol, Avon); 2009 Jul; 24(6):480-7. PubMed ID: 19368993
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical Robustness of a Contemporary Cementless Stem to Surgical Variation in Stem Size and Position.
Al-Dirini RMA; O'Rourke D; Huff D; Martelli S; Taylor M
J Biomech Eng; 2018 Sep; 140(9):. PubMed ID: 29801163
[TBL] [Abstract][Full Text] [Related]