BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

771 related articles for article (PubMed ID: 26923198)

  • 21. Three-dimensional intra- and extracranial arterial vessel wall joint imaging in patients with cerebrovascular disease.
    Jia L; Zhang N; Kukun H; Ren L; Zhang L; Lyu J; Liang D; Li Y; Zheng H; Jia W; Liu X
    Eur J Radiol; 2020 May; 126():108921. PubMed ID: 32145599
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intracranial vessel wall imaging at 7.0-T MRI.
    van der Kolk AG; Zwanenburg JJ; Brundel M; Biessels GJ; Visser F; Luijten PR; Hendrikse J
    Stroke; 2011 Sep; 42(9):2478-84. PubMed ID: 21757674
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-recalled echo sequence versus conventional fat-suppressed contrast-enhanced T1-weighted studies of the head and neck.
    Wu X; Raz E; Block TK; Geppert C; Hagiwara M; Bruno MT; Fatterpekar GM
    AJR Am J Roentgenol; 2014 Oct; 203(4):883-9. PubMed ID: 25247956
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus.
    Zhu C; Haraldsson H; Faraji F; Owens C; Gasper W; Ahn S; Liu J; Laub G; Hope MD; Saloner D
    Magn Reson Imaging; 2016 Jan; 34(1):18-25. PubMed ID: 26471514
    [TBL] [Abstract][Full Text] [Related]  

  • 25. High-Resolution Vessel Wall Magnetic Resonance Imaging in Angiogram-Negative Non-Perimesencephalic Subarachnoid Hemorrhage.
    Coutinho JM; Sacho RH; Schaafsma JD; Agid R; Krings T; Radovanovic I; Matouk CC; Mikulis DJ; Mandell DM
    Clin Neuroradiol; 2017 Jun; 27(2):175-183. PubMed ID: 26608742
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Noncontrast-enhanced three-dimensional magnetic resonance aortography of the thorax at 3.0 T using respiratory-compensated T1-weighted k-space segmented gradient-echo imaging with radial data sampling: preliminary study.
    Amano Y; Takahama K; Kumita S
    Invest Radiol; 2009 Sep; 44(9):548-52. PubMed ID: 19652612
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.
    Yoon MA; Hong SJ; Lee KC; Lee CH
    J Comput Assist Tomogr; 2019; 43(1):46-50. PubMed ID: 29901511
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Turbo fast three-dimensional carotid artery black-blood MRI by combining three-dimensional MERGE sequence with compressed sensing.
    Li B; Dong L; Chen B; Ji S; Cai W; Wang Y; Zhang J; Zhang Z; Wang X; Fang J
    Magn Reson Med; 2013 Nov; 70(5):1347-52. PubMed ID: 23280949
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimized 4D time-of-flight MR angiography using saturation pulse.
    Shibukawa S; Nishio H; Niwa T; Obara M; Miyati T; Hara T; Imai Y; Muro I
    J Magn Reson Imaging; 2016 Jun; 43(6):1320-6. PubMed ID: 26666670
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.
    Xie Y; Yang Q; Xie G; Pang J; Fan Z; Li D
    Magn Reson Med; 2016 Jun; 75(6):2286-94. PubMed ID: 26152900
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Prospective motion correction and selective reacquisition using volumetric navigators for vessel-encoded arterial spin labeling dynamic angiography.
    Frost R; Hess AT; Okell TW; Chappell MA; Tisdall MD; van der Kouwe AJ; Jezzard P
    Magn Reson Med; 2016 Nov; 76(5):1420-1430. PubMed ID: 26567122
    [TBL] [Abstract][Full Text] [Related]  

  • 32. SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.
    Lee H; Park J
    Magn Reson Med; 2013 Jul; 70(1):106-16. PubMed ID: 22890939
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Relaxation enhanced compressed sensing three-dimensional black-blood vessel wall MR imaging: Preliminary studies.
    Li B; Li H; Li J; Zhang Y; Wang X; Zhang J; Dong L; Fang J
    Magn Reson Imaging; 2015 Sep; 33(7):932-8. PubMed ID: 25863136
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding.
    Okell TW; Schmitt P; Bi X; Chappell MA; Tijssen RH; Sheerin F; Miller KL; Jezzard P
    NMR Biomed; 2016 Jun; 29(6):776-86. PubMed ID: 27074149
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI.
    Zhu C; Haraldsson H; Tian B; Meisel K; Ko N; Lawton M; Grinstead J; Ahn S; Laub G; Hess C; Saloner D
    MAGMA; 2016 Jun; 29(3):559-70. PubMed ID: 26946509
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Three-dimensional magnetic resonance observation of cartilage repair tissue (MOCART) score assessed with an isotropic three-dimensional true fast imaging with steady-state precession sequence at 3.0 Tesla.
    Welsch GH; Zak L; Mamisch TC; Resinger C; Marlovits S; Trattnig S
    Invest Radiol; 2009 Sep; 44(9):603-12. PubMed ID: 19692843
    [TBL] [Abstract][Full Text] [Related]  

  • 37. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.
    Lee S; Jee WH; Jung JY; Lee SY; Ryu KS; Ha KY
    Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intracranial cerebrospinal fluid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution.
    Hodel J; Silvera J; Bekaert O; Rahmouni A; Bastuji-Garin S; Vignaud A; Petit E; Durning B; Decq P
    Eur Radiol; 2011 Feb; 21(2):402-10. PubMed ID: 20725835
    [TBL] [Abstract][Full Text] [Related]  

  • 39. MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence.
    Takano K; Yamashita S; Takemoto K; Inoue T; Kuwabara Y; Yoshimitsu K
    Neuroradiology; 2013 Jul; 55(7):845-51. PubMed ID: 23619699
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Measuring the labeling efficiency of pseudocontinuous arterial spin labeling.
    Chen Z; Zhang X; Yuan C; Zhao X; van Osch MJP
    Magn Reson Med; 2017 May; 77(5):1841-1852. PubMed ID: 27174204
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 39.