70 related articles for article (PubMed ID: 26927207)
1. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.
Mukai T; Yasuda I; Isayama H; Iwashita T; Itoi T; Kawakami H; Kogure H; Nakai Y
Dig Endosc; 2016 Sep; 28(6):671-9. PubMed ID: 26927207
[TBL] [Abstract][Full Text] [Related]
2. Efficacy of multi-hole self-expandable metal stent compared to fully covered and uncovered self-expandable metal stents in patients with unresectable malignant distal biliary obstruction: a propensity analysis.
Kulpatcharapong S; Piyachaturawat P; Mekaroonkamol P; Angsuwatcharakon P; Ridtitid W; Kongkam P; Rerknimitr R
Surg Endosc; 2024 Jan; 38(1):212-221. PubMed ID: 37964091
[TBL] [Abstract][Full Text] [Related]
3. Comparison of covered self-expandable metallic stents with 12-mm and 10-mm diameters for unresectable malignant distal biliary obstructions: a prospective randomized trial.
Mukai T; Iwata K; Iwashita T; Doi S; Kawakami H; Okuno M; Maruta A; Uemura S; Shimizu M; Yasuda I
Gastrointest Endosc; 2024 May; 99(5):732-738. PubMed ID: 38000479
[TBL] [Abstract][Full Text] [Related]
4. Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study.
Tamura T; Yamai T; Uza N; Yamasaki T; Masuda A; Tomooka F; Maruyama H; Shigekawa M; Ogura T; Kuriyama K; Asada M; Matsumoto H; Takenaka M; Mandai K; Osaki Y; Matsumoto K; Sanuki T; Shiomi H; Yamagata Y; Doi T; Inatomi O; Nakanishi F; Emori T; Shimatani M; Asai S; Fujigaki S; Shimokawa T; Kitano M
Gastrointest Endosc; 2024 Jan; 99(1):61-72.e8. PubMed ID: 37598864
[TBL] [Abstract][Full Text] [Related]
5. A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study.
Sakai A; Masuda A; Eguchi T; Furumatsu K; Iemoto T; Yoshida S; Okabe Y; Yamanaka K; Miki I; Kakuyama S; Yagi Y; Shirasaka D; Kohashi S; Kobayashi T; Shiomi H; Kodama Y
Clin Endosc; 2024 May; 57(3):375-383. PubMed ID: 37430394
[TBL] [Abstract][Full Text] [Related]
6. Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study.
Togawa O; Isayama H; Kawakami H; Nakai Y; Mohri D; Hamada T; Kogure H; Kawakubo K; Sakamoto N; Koike K; Kita H
Saudi J Gastroenterol; 2018; 24(3):151-156. PubMed ID: 29652026
[TBL] [Abstract][Full Text] [Related]
7. Outcomes of 6-mm diameter fully covered self-expandable metal stents for preoperative biliary drainage in pancreatic cancer.
Nakagawa H; Takeda T; Okamoto T; Mie T; Kasuga A; Sasaki T; Ozaka M; Matsuda T; Igarashi Y; Sasahira N
DEN Open; 2024 Apr; 4(1):e360. PubMed ID: 38601271
[TBL] [Abstract][Full Text] [Related]
8. Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial.
Paik WH; Jung MK; Kim DU; Song TJ; Yang MJ; Choi YH; Kim JS; Lee MW; Choi JH; Lee SH
Dig Endosc; 2024 Apr; 36(4):473-480. PubMed ID: 37612129
[TBL] [Abstract][Full Text] [Related]
9. Efficacy and safety of uncovered self-expandable metal stents for distal malignant biliary obstruction in unresectable non-pancreatic cancer.
Niiya F; Tamai N; Yamawaki M; Noda J; Azami T; Takano Y; Nishimoto F; Nagahama M
DEN Open; 2025 Apr; 5(1):e383. PubMed ID: 38827185
[TBL] [Abstract][Full Text] [Related]
10. Fully covered versus partially covered self-expandable metal stents for palliation of distal malignant biliary obstruction: a systematic review and meta-analysis.
Vanella G; Coluccio C; Cucchetti A; Leone R; Dell'Anna G; Giuffrida P; Abbatiello C; Binda C; Fabbri C; Arcidiacono PG
Gastrointest Endosc; 2024 Mar; 99(3):314-322.e19. PubMed ID: 37813199
[TBL] [Abstract][Full Text] [Related]
11. Evaluating optimal bilateral biliary stenting in endoscopic reintervention after initial plastic stent dysfunction for unresectable malignant hilar biliary obstruction: Retrospective cross-sectional study.
Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
Dig Endosc; 2024 Mar; ():. PubMed ID: 38486465
[TBL] [Abstract][Full Text] [Related]
12. Long-term outcomes of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.
Hedjoudje A; Pokossy Epée J; Perez-Cuadrado-Robles E; Alric H; Rivallin P; Vuitton L; Koch S; Prat F
United European Gastroenterol J; 2024 Apr; ():. PubMed ID: 38578654
[TBL] [Abstract][Full Text] [Related]
13. Braided-type stent versus laser-cut-type stent for patients with unresectable distal malignant biliary obstruction: a randomized controlled trial.
Hasegawa S; Sato T; Shinoda S; Kurita Y; Ogata T; Nihei S; Yagi S; Hosono K; Endo I; Kobayashi N; Kubota K; Nakajima A
Gastrointest Endosc; 2024 May; 99(5):739-746.e1. PubMed ID: 38065510
[TBL] [Abstract][Full Text] [Related]
14. Novel tapered-and-flared fully covered self-expandable metal stent for distal bile duct obstruction.
Kobayashi M; Kato H; Tominaga S; Yano M
Endoscopy; 2024 Dec; 56(S 01):E464-E465. PubMed ID: 38838725
[No Abstract] [Full Text] [Related]
15. Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study.
Okamoto T; Sasaki T; Takeda T; Hirai T; Ishitsuka T; Yamada M; Nakagawa H; Mie T; Furukawa T; Kasuga A; Ozaka M; Sasahira N
Clin Endosc; 2024 May; ():. PubMed ID: 38725401
[TBL] [Abstract][Full Text] [Related]
16. Choice of plastic or metal stent for patients with jaundice with pancreaticobiliary malignancy using simple clinical tools: a prospective evaluation.
Wilcox CM; Kim H; Seay T; Varadarajulu S
BMJ Open Gastroenterol; 2015; 2(1):e000014. PubMed ID: 26462270
[TBL] [Abstract][Full Text] [Related]
17. Prophylactic endoscopic transpapillary gallbladder stenting to prevent acute cholecystitis induced after metallic stent placement for malignant biliary strictures: a retrospective study, Japan.
Kozakai F; Kanno Y; Koshita S; Ogawa T; Kusunose H; Sakai T; Yonamine K; Miyamoto K; Okano H; Matsuoka Y; Hosokawa K; Sumiya H; Ito K
Clin Endosc; 2024 May; ():. PubMed ID: 38756066
[TBL] [Abstract][Full Text] [Related]
18. Effects of Clip Anchoring on Preventing Migration of Fully Covered Self-Expandable Metal Stent in Patients Undergoing Endoscopic Retrograde Cholangiopancreatography: A Multicenter, Randomized Controlled Study.
Wang X; Shi X; Luo H; Ren G; Wang X; Zhao J; Li H; Ning B; Yi H; Zhong L; Zhang R; Ni Z; Liang S; Xia M; Hu B; Pan Y; Fan D
Am J Gastroenterol; 2024 May; ():. PubMed ID: 38619136
[TBL] [Abstract][Full Text] [Related]
19. Covered self-expandable metallic stent placement for tumor bleeding from duodenal invasion in patients with unresectable pancreatic cancer.
Shibuki T; Fukushi K; Inoue K; Taira T; Satake T; Watanabe K; Sasaki M; Imaoka H; Mitsunaga S; Ikeda M
DEN Open; 2024 Apr; 4(1):e361. PubMed ID: 38601268
[TBL] [Abstract][Full Text] [Related]
20. Impact of sarcopenia on biliary drainage during neoadjuvant therapy for pancreatic cancer.
Kataoka K; Ohno E; Ishikawa T; Yamao K; Mizutani Y; Iida T; Takami H; Maeda O; Yamaguchi J; Yokoyama Y; Ebata T; Kodera Y; Kawashima H
Clin Endosc; 2024 Jan; 57(1):112-121. PubMed ID: 37460104
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]